Physiological responses in reindeer to the application of a conducted electrical weapon

被引:0
|
作者
Lieske, Camilla L. [1 ]
Beckmen, Kimberlee B. [1 ]
Lewis, Larry L. [2 ]
机构
[1] Alaska Dept Fish & Game, Div Wildlife Conservat, 1300 Coll Rd, Fairbanks, AK 99701 USA
[2] Alaska Dept Fish & Game, Div Wildlife Conservat, 43961 Kalifornsky Beach Rd B, Soldotna, AK 99669 USA
来源
HUMAN-WILDLIFE INTERACTIONS | 2018年 / 12卷 / 02期
关键词
conducted electrical weapon; physiological response; Rangifer tarandus tarandus; reindeer; TASER (R); CHEMICAL IMMOBILIZATION; BIGHORN SHEEP; TROPONIN-I; EXERCISE; ACIDOSIS; DEVICES; FORCE;
D O I
暂无
中图分类号
X176 [生物多样性保护];
学科分类号
090705 ;
摘要
Conducted electrical weapons (CEWs) have potential as effective alternatives to chemical restraint for short-term nonroutine capture and handling of wildlife. To assess immediate and delayed physiologic effects of exposure to a CEW, we assigned 15 captive reindeer (Rangifer tarandus tarandus) to 1 of 3 treatment groups: immobilized with carfentanil and xylazine(CX), 10-second exposure to a CEW, or exposure to the CEW while immobilized with CX (CEW+CX). Blood samples were collected pre-treatment, immediately post-intervention, 10 minutes, 20 minutes, 4 hours, and 24 hours post-intervention. Physiologic effects were evaluated by analysis of blood, clinical observation for signs of physiologic compromise, and vital signs. Parameters that changed significantly (P < 0.05) post-exposure (lactate, glucose, rectal temperature, blood oxygen, cardiac troponin I, cortisol, and catecholamines) were not significantly different from baseline values within 24 hours. Cortisol, glucose, and peak rectal temperature were lower in CEW-exposed individuals, while lactate, oxygen, and catecholamines were higher than for the CX-exposed individuals. The catecholamine response observed in the CEW-only group paralleled the response in the CEW+CX group. No long-term health effects were detected from either restraint method. Use of a CEW does not appear to increase the risk of capture myopathy.
引用
收藏
页码:160 / 170
页数:11
相关论文
共 50 条
  • [41] The neuroendocrine effects of the TASER X26 conducted electrical weapon as compared to oleoresin capsicum
    Dawes, D. M.
    Ho, J. D.
    Miner, J. R.
    Johnson, M.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) : S132 - S133
  • [42] A TASER conducted electrical weapon with cardiac biomonitoring capability: Proof of concept and initial human trial
    Stopyra, Jason P.
    Ritter, Samuel I.
    Beatty, Jennifer
    Johnson, James C.
    Kleiner, Douglas M.
    Winslow, James E., III
    Gardner, Alison R.
    Bozeman, William P.
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2016, 43 : 48 - 52
  • [43] Conducted electrical weapon incapacitation during a goal-directed task as a function of probe spread
    Ho, Jeffrey
    Dawes, Donald
    Miner, James
    Kunz, Sebastian
    Nelson, Rebecca
    Sweeney, James
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2012, 8 (04) : 358 - 366
  • [44] Echocardiographic Determination of Cardiac Rhythm During Trans-thoracic Wireless Conducted Electrical Weapon Exposure
    Ho, J. D.
    Dawes, D. M.
    Reardon, R. F.
    Lapine, A. L.
    Miner, J. R.
    ANNALS OF EMERGENCY MEDICINE, 2008, 52 (04) : S62 - S62
  • [45] Physiologic Changes with an Exposure to a New Concept Conducted Electrical Weapon (T10™) in Human Volunteers
    Dawes D.M.
    Ho J.D.
    Kunz S.N.
    Kuo J.
    Knack S.K.
    Human Factors and Mechanical Engineering for Defense and Safety, 8 (1):
  • [46] Respiratory effect of prolonged electrical weapon application on human volunteers
    Ho, Jeffrey D.
    Dawes, Donald M.
    Bultman, Laura L.
    Thacker, Jenny L.
    Skinner, Lisa D.
    Bahr, Jennifer M.
    Johnson, Mark A.
    Miner, James R.
    ACADEMIC EMERGENCY MEDICINE, 2007, 14 (03) : 197 - 201
  • [47] PHYSIOLOGICAL-RESPONSES AND EFFECTS ON MEAT QUALITY IN REINDEER (RANGIFER TARANDUS) TRANSPORTED ON LORRIES
    HANSSEN, I
    KYRKJEBO, A
    OPSTAD, PK
    PROSCH, R
    ACTA VETERINARIA SCANDINAVICA, 1984, 25 (01) : 128 - 138
  • [48] Cardiac effects of the Taser conducted energy weapon
    Barnes, D. G., Jr.
    Winslow, J. E., III
    Alson, R. L.
    Johnson, J.
    Bozeman, W. P.
    ANNALS OF EMERGENCY MEDICINE, 2006, 48 (04) : S102 - S102
  • [49] Physiological effects of the TASERA® C2 conducted energy weapon (vol 5, pg 189, 2009)
    Jauchem, James R.
    Seaman, Ronald L.
    Klages, Curtis M.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2009, 5 (04) : 330 - 330
  • [50] Physiological imaging of electrical trauma and therapeutic responses
    Chen, CT
    Matthews, KL
    Aarsvold, JN
    Mintzer, RA
    Yasillo, NJ
    Hannig, J
    Capelli-Schellpfeffer, M
    Cooper, M
    Lee, RC
    MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 331 - 335