The periodic moving average filter for removing motion artifacts from PPG signals

被引:1
|
作者
Lee, Han-Wook
Lee, Ju-Won
Jung, Won-Geun
Lee, Gun-Ki
机构
[1] Gyeongsang Natl Univ, Dept Elect Engn, Jinju Si 660701, Kyungnam, South Korea
[2] Nam Hae Coll, Dept Elect & Commun, Kyungnam 668801, South Korea
关键词
heart rate; motion artifact; moving average; PPG; SpO(2);
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The measurement accuracy for heart rate or SpO(2) using photoplethysmography (PPG) is influenced by how well the noise from motion artifacts and other sources can be removed. Eliminating the motion artifacts is particularly difficult since its frequency band overlaps that of the basic PPG signal. Therefore, we propose the Periodic Moving Average Filter (PMAF) to remove motion artifacts. The PMAF is based on the quasi-periodicity of the PPG signals. After segmenting the PPG signal on periodic boundaries, we average the m(th) samples of each period. As a result, we remove the motion artifacts well without the deterioration of the characteristic point.
引用
收藏
页码:701 / 706
页数:6
相关论文
共 50 条
  • [31] A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter
    Ram, M. Raghu
    Madhav, K. Venu
    Krishna, E. Hari
    Komalla, Nagarjuna Reddy
    Reddy, K. Ashoka
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (05) : 1445 - 1457
  • [32] Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts
    Dubey, Harishchandra
    Kumaresan, Ramdas
    Mankodiya, Kunal
    JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2018, 9 (01) : 137 - 150
  • [33] Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts
    Harishchandra Dubey
    Ramdas Kumaresan
    Kunal Mankodiya
    Journal of Ambient Intelligence and Humanized Computing, 2018, 9 : 137 - 150
  • [34] SYNTHESIS OF INPUT SIGNALS FOR PARAMETER-IDENTIFICATION USING MOVING-AVERAGE FILTER
    BERGER, CS
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1979, 126 (12): : 1311 - 1315
  • [35] On the performance of wavelets in reducing motion artifacts from photoplethysmographic signals
    Raghuram, M.
    Madhav, K. Venu
    Krishna, E. Hari
    Reddy, K. Ashoka
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [36] Multichannel techniques for motion artifacts removal from electrocardiographic signals
    Milanesi, M.
    Martini, N.
    Vanello, N.
    Positano, V.
    Santarelli, M. F.
    Paradiso, R.
    De Rossi, D.
    Landini, L.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2684 - +
  • [37] Application of Tensor Decomposition in Removing Motion Artifacts from the Measurements of a Wireless Electrocardiogram
    Lilienthal, Jannis
    Dargie, Waltenegus
    PROCEEDINGS OF 2020 23RD INTERNATIONAL CONFERENCE ON INFORMATION FUSION (FUSION 2020), 2020, : 630 - 637
  • [38] Hybrid Convolutional Networks for End-to-End Event Detection in Concurrent PPG and PCG Signals Affected by Motion Artifacts
    Marzorati, Davide
    Dorizza, Andrea
    Bovio, Dario
    Salito, Caterina
    Mainardi, Luca
    Cerveri, Pietro
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (08) : 2512 - 2523
  • [39] Moving average restoration of bandlimited signals from noisy observations
    Krzyzak, A
    Rafajlowicz, E
    Pawlak, M
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (12) : 2967 - 2976
  • [40] Dual-component model of respiratory motion based on the periodic autoregressive moving average (periodic ARMA) method
    McCall, K. C.
    Jeraj, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12): : 3455 - 3466