The dependence of the modulation transfer function on the blocking layer thickness in amorphous selenium x-ray detectors

被引:6
|
作者
Hunter, David M.
Belev, Gueorgi
DeCrescenzo, Giovanni
Kasap, Safa O.
Mainprize, James G.
Rowlands, J. A.
Smith, Charles
Tuemer, Tuemay
Verpakhovski, Vladimir
Yin, Shi
Yaffe, Martin J.
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Saskatchewan, Dept Elect Engn, Saskatoon, SK S7N 5A9, Canada
[3] DALSA Inc, Waterloo, ON N2V 2E9, Canada
[4] NOVA R&D, Riverside, CA 92507 USA
关键词
amorphous selenium; modulation transfer function; CCD; blocking layer; x-ray; digital mammography;
D O I
10.1118/1.2757002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Blocking layers are used to reduce leakage current in amorphous selenium detectors. The effect of the thickness of the blocking layer on the presampling modulation transfer function (MTF) and on dark current was experimentally determined in prototype single-line CCD-based amorphous selenium (a-Se) x-ray detectors. The sampling pitch of the detectors evaluated was 25 mu m and the blocking layer thicknesses varied from 1 to 51 mu m. The blocking layers resided on the signal collection electrodes which, in this configuration, were used to collect electrons. The combined thickness of the blocking layer and a-Se bulk in each detector was similar to 200 mu m. As expected, the dark current increased monotonically as the thickness of the blocking layer was decreased. It was found that if the blocking layer thickness was small compared to the sampling pitch, it caused a negligible reduction in MTF. However, the MTF was observed to decrease dramatically at spatial frequencies near the Nyquist frequency as the blocking layer thickness approached or exceeded the electrode sampling pitch. This observed reduction in MTF is shown to be consistent with predictions of an electrostatic model wherein the image charge from the a-Se is trapped at a characteristic depth within the blocking layer, generally near the interface between the blocking layer and the a-Se bulk. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3358 / 3373
页数:16
相关论文
共 50 条
  • [41] Wavefront transformation and the modulation transfer function of x-ray multilayer mirrors
    Artioukov, IA
    Fechtchenko, RM
    Vinogradov, AV
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2002, 4 (03): : 233 - 236
  • [42] MEASUREMENT OF MODULATION TRANSFER-FUNCTION OF X-RAY TOMOGRAPHIC SYSTEMS
    AMTEY, SR
    ISRAEL, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 596 - 596
  • [43] Technical Note: Further development of a resolution modification routine for the simulation of the modulation transfer function of digital x-ray detectors
    Konstantinidis, Anastasios C.
    Olivo, Alessandro
    Speller, Robert D.
    MEDICAL PHYSICS, 2011, 38 (11) : 5916 - 5920
  • [44] A method for determining the information capacity of x-ray imaging scintillator detectors by means of luminescence and modulation transfer function measurements
    Kandarakis, I
    Cavouras, D
    Kanellopoulos, E
    Nomicos, CD
    Panayiotakis, GS
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (01) : 25 - 30
  • [45] A method for determining the information capacity of x-ray imaging scintillator detectors by means of luminescence and modulation transfer function measurements
    I. Kandarakis
    D. Cavouras
    E. Kanellopoulos
    C. D. Nomicos
    G. S. Panayiotakis
    Medical & Biological Engineering & Computing, 1999, 37 : 25 - 30
  • [46] Effect of repeated x-ray exposure on the resolution of amorphous selenium based x-ray imagers
    Kabir, M. Z.
    Chowdhury, L.
    DeCrescenzo, G.
    Tousignant, O.
    Kasap, S. O.
    Rowlands, J. A.
    MEDICAL PHYSICS, 2010, 37 (03) : 1339 - 1349
  • [47] Thickness Uniformity and Stability of Amorphous Selenium Films on Flexible Substrates for Indirect Conversion X-ray Detection
    Farahmandzadeh, Maryam
    Marcinko, Steven
    Curreli, Davide
    Abbaszadeh, Shiva
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [48] Flexible Amorphous Silicon PIN Diode X-Ray Detectors
    Marrs, Michael
    Bawolek, Edward
    Smith, Joseph T.
    Raupp, Gregory B.
    Morton, David
    FLEXIBLE ELECTRONICS, 2013, 8730
  • [49] High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout
    Han, Z.
    Mukherjee, A.
    Albert, A.
    Rumaiz, A. K.
    Harding, I.
    Tate, M. W.
    Gruner, S. M.
    Thom-Levy, J.
    Kuczewski, A. J.
    Siddons, D. P.
    Carini, G. A.
    Stavro, J.
    Leveille, S.
    Vasileska, D.
    Zhao, W.
    Goldan, A.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [50] X-Ray Detectors Based on Amorphous InGaZnO Thin Films
    Huang, Wen-Chun
    Tseng, Zi-Chun
    Hsueh, Wen-Jeng
    Liao, Su-Yu
    Huang, Chun-Ying
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2023, 70 (07) : 3690 - 3694