Validity and reliability of elastic resistance bands for measuring shoulder muscle strength

被引:23
|
作者
Andersen, L. L. [1 ,2 ]
Vinstrup, J. [1 ]
Jakobsen, M. D. [1 ]
Sundstrup, E. [1 ]
机构
[1] Natl Res Ctr Working Environm, Lerso Pk Alle 105, DK-2100 Copenhagen, Denmark
[2] Aalborg Univ, Phys Act & Human Performance Grp, Dept Hlth Sci & Technol, SMI, Aalborg, Denmark
关键词
Reliability; validity; sports medicine; muscle strength; shoulder; elastic resistance; test-retest; ICC; HAND-HELD DYNAMOMETRY; TEST-RETEST RELIABILITY; AGREEMENT; QUALITY;
D O I
10.1111/sms.12695
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Valid and reliable measurements of muscle strength are important in sport medicine. This study assesses concurrent validity and intrarater reliability (test-retest reliability) of elastic resistance bands for measuring shoulder muscle strength. Altogether, 50 healthy adults [mean age 36.0 (SD: 11.6), 29 women and 21 men] participated in testing and retesting 1-2weeks later. The maximal elastic resistance (TheraBand) that each participant could hold for 3s during standing bilateral shoulder abduction to 90 degrees was converted into torque and validated against gold standard maximal voluntary isometric contraction (MVC) (Vishay force transducer) performed unilaterally while lying supine. The intrarater reliability of both tests were high; for the MVC and elastic band test, respectively, ICC(3,1) was 0.98 (95% CI: 0.97-0.99) and 0.99 (95% CI: 0.98-1.00), and measurement error was 4.8% (95% CI: 3.7-5.9) and 4.7% (95% CI: 3.1-6.2). For concurrent validity, ICC(3,1) was 0.96 (95% CI: 0.95-0.98) and measurement error was 8.1% (95% CI: 6.6-9.6), and the elastic band test explained 93% of the variance in the MVC test. However, the elastic band test produced systematically lower torque values than the MVC [56.5 (SD: 26.8) vs 66.5 (SD: 25.5) Nm, P<0.01]. In conclusion, the test for shoulder muscle strength using elastic resistance bands has excellent validity and reliability, but produces systematically lower torque values than MVC. The reason for the lower torque values may be that the elastic band test has an initial concentric phase and is performed bilaterally and standing upright.
引用
收藏
页码:887 / 894
页数:8
相关论文
共 50 条
  • [21] Investigation of the validity and reliability of four objective techniques for measuring forward shoulder posture
    Peterson, DE
    Blankenship, KR
    Robb, JB
    Walker, MJ
    Bryan, JM
    Stetts, DM
    Mincey, LM
    Simmons, GE
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1997, 25 (01): : 34 - 42
  • [22] Reliability and validity of a new method of measuring posterior shoulder tightness - Author response
    Tyler, TF
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1999, 29 (05): : 273 - 274
  • [23] Reliability and Validity of Cervical Range of Motion and Muscle Strength Testing
    Kubas, Christian
    Chen, Yi-Wen
    Echeverri, Silvana
    McCann, Stephanie L.
    Denhoed, Marcia J.
    Walker, Catherine J.
    Kennedy, Carol N.
    Reid, W. Darlene
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (04) : 1087 - 1096
  • [24] Validity and reliability of isokinetic strength ratios for estimating muscle imbalances
    Ayala, Francisco
    Sainz de Baranda, Pilar
    de Ste Croix, Mark
    Santonja, Fernando
    APUNTS-MEDICINA DE L ESPORT, 2012, 47 (176) : 131 - 142
  • [25] Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
    Sousa, Antonio Carlos
    Marques, Diogo Luis
    Calado, Antonio Manuel
    Pacheco, Carlos
    Marinho, Daniel Almeida
    Marques, Mario Cardoso
    Travassos, Bruno Filipe
    JOURNAL OF HUMAN KINETICS, 2022, 82 (01) : 51 - 59
  • [26] Test-retest reliability in isokinetic muscle strength measurements of the shoulder
    van Meeteren, J
    Roebroeck, ME
    Stam, HJ
    JOURNAL OF REHABILITATION MEDICINE, 2002, 34 (02) : 91 - 95
  • [27] Assessing posterior shoulder contracture: The reliability and validity of measuring glenohumeral joint horizontal adduction
    Laudner, Kevin G.
    Stanek, Justin M.
    Meister, Keith
    JOURNAL OF ATHLETIC TRAINING, 2006, 41 (04) : 375 - 380
  • [28] Strength training with elastic bands
    Fuezeki, Eszter
    ZENTRALBLATT FUR ARBEITSMEDIZIN ARBEITSSCHUTZ UND ERGONOMIE, 2020, 70 (04): : 173 - 176
  • [29] Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility
    Muyor, Jose M.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2017, 38 (09) : 691 - 695
  • [30] Reliability Of A Custom Dynamometer For Measuring Isometric Hip Muscle Strength
    Roewer, Benjamin D.
    Lowe, Sarah E.
    Di Stasi, Stephanie L.
    Myer, Gregory D.
    Hewett, Timothy E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 690 - 690