Percutaneous vertebral augmentation using drill rotation for osteoporotic vertebral compression fractures with intravertebral vacuum cleft

被引:12
|
作者
Li, Min [1 ]
Zhang, Yue [2 ]
Jin, Peng [3 ]
Jia, Pu [4 ]
Liu, Xun-wei [3 ]
Tang, Hai [4 ]
Sun, Gang [3 ]
机构
[1] 960 Hosp PLA, Dept Nucl Med, Jinan 250031, Shandong, Peoples R China
[2] Zhangqiu Tradit Chinese Med Hosp, Dept Gynaecol & Obstet, Jinan 250031, Shandong, Peoples R China
[3] 960 Hosp PLA, Dept Med Imaging, Jinan 250031, Shandong, Peoples R China
[4] Capital Med Univ, Beijing Friendship Hosp, Dept Orthoped, Beijing 100050, Peoples R China
关键词
Spine; Vertebroplasty; Fractures; Compression; Back pain; Bone cements; VERTEBROPLASTY; SIGN; PSEUDOARTHROSIS; OSTEONECROSIS; EFFICACY; BODY;
D O I
10.1007/s00256-020-03437-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To evaluate the efficacy of a new technique of percutaneous vertebral augmentation (PVA): drill rotation-cement injected under vacuum aspiration (DR-CIVAS) for vertebral compression fractures (OVCFs) with intravertebral vacuum cleft (IVC) sign. Materials and methods A retrospective study was conducted in 46 consecutive patients with OVCFs and IVC signs, who underwent PVA using DR-CIVAS (n = 22, DR-CIVAS group) or traditional technique without DR-CIVAS (n = 24, control group). The pre- and postoperative vertebral height and wedge angle change and visual analog scale (VAS), the volume of cement injected, incidences of cement leakage, and subsequent new vertebral compression fractures were evaluated between the two groups. Results No significant difference was found in cement leakage incidences, pre- and postoperative VAS scores, vertebral height, and wedge angle change between the two groups. The mean cement volume was significantly higher (P < 0.001) in DR-CIVAS group (4.87 mL) than in the control group (3.58 mL). Of the 22 patients in DR-CIVAS group, the subsequent fractures occurred in 2 cases (9.1%) located in the nonadjacent levels. In the control group, the subsequent fractures occurred in 6 cases (25.0%) located in the adjacent level (n = 1) and the augmented levels (n = 5). Although DR-CIVAS group did not demonstrate a statistical reduction of the incidence of subsequent fractures (P = 0.25), the subgroup analysis revealed that subsequent fractures frequently involved the augmented level in the control group (P = 0.04). Conclusions PVA with DR-CIVAS technique is effective for OVCFs with IVC sign, with lower incidences of subsequent new vertebral compression fractures in the augmented vertebra.
引用
收藏
页码:1459 / 1465
页数:7
相关论文
共 50 条
  • [31] Percutaneous vertebroplasty for osteoporotic vertebral compression fracture with intravertebral cleft associated with delayed neurologic deficit
    Toshio Nakamae
    Yoshinori Fujimoto
    Kiyotaka Yamada
    Haruhiko Takata
    Takuro Shimbo
    Yasuyuki Tsuchida
    European Spine Journal, 2013, 22 : 1624 - 1632
  • [32] Outcomes of Augmentation in Osteoporotic Vertebral Compression Fractures Showing a Cleft Sign on MRI
    Jing Tang
    Jin Liu
    Zuchao Gu
    Bin Song
    CardioVascular and Interventional Radiology, 2021, 44 : 428 - 435
  • [33] Percutaneous vertebroplasty for osteoporotic vertebral compression fracture with intravertebral cleft associated with delayed neurologic deficit
    Nakamae, Toshio
    Fujimoto, Yoshinori
    Yamada, Kiyotaka
    Takata, Haruhiko
    Shimbo, Takuro
    Tsuchida, Yasuyuki
    EUROPEAN SPINE JOURNAL, 2013, 22 (07) : 1624 - 1632
  • [34] Outcomes of Augmentation in Osteoporotic Vertebral Compression Fractures Showing a Cleft Sign on MRI
    Tang, Jing
    Liu, Jin
    Gu, Zuchao
    Song, Bin
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (03) : 428 - 435
  • [35] Adjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a comparison of balloon kyphoplasty and vertebroplasty
    I. Movrin
    R. Vengust
    R. Komadina
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1157 - 1166
  • [36] Adjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a comparison of balloon kyphoplasty and vertebroplasty
    Movrin, I.
    Vengust, R.
    Komadina, R.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (09) : 1157 - 1166
  • [37] Risk factors for bone cement displacement after percutaneous vertebral augmentation for osteoporotic vertebral compression fractures
    Gao, Xiangcheng
    Du, Jinpeng
    Gao, Lin
    Hao, Dingjun
    Hui, Hua
    He, Baorong
    Yan, Liang
    FRONTIERS IN SURGERY, 2022, 9
  • [38] ALENDRONATE USE PREVENTS NEW VERTEBRAL COMPRESSION FRACTURES IN OSTEOPOROTIC PATIENTS AFTER PERCUTANEOUS VERTEBRAL AUGMENTATION
    Wang, Q.
    Lu, C.
    Zhang, L.
    Deng, Q.
    Wei, S.
    Chen, D.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 : 382 - 382
  • [39] Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts
    Ha, K. -Y.
    Lee, J. -S.
    Kim, K. -W.
    Chon, J. -S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05): : 629 - 633
  • [40] Percutaneous Vertebral Augmentation Techniques in Osteoporotic and Traumatic Fractures
    Bousson, Valerie
    Hamze, Bassam
    Odri, Guillaume
    Funck-Brentano, Thomas
    Orcel, Philippe
    Laredo, Jean-Denis
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2018, 35 (04) : 309 - 323