Percutaneous vertebral augmentation using drill rotation for osteoporotic vertebral compression fractures with intravertebral vacuum cleft

被引:12
|
作者
Li, Min [1 ]
Zhang, Yue [2 ]
Jin, Peng [3 ]
Jia, Pu [4 ]
Liu, Xun-wei [3 ]
Tang, Hai [4 ]
Sun, Gang [3 ]
机构
[1] 960 Hosp PLA, Dept Nucl Med, Jinan 250031, Shandong, Peoples R China
[2] Zhangqiu Tradit Chinese Med Hosp, Dept Gynaecol & Obstet, Jinan 250031, Shandong, Peoples R China
[3] 960 Hosp PLA, Dept Med Imaging, Jinan 250031, Shandong, Peoples R China
[4] Capital Med Univ, Beijing Friendship Hosp, Dept Orthoped, Beijing 100050, Peoples R China
关键词
Spine; Vertebroplasty; Fractures; Compression; Back pain; Bone cements; VERTEBROPLASTY; SIGN; PSEUDOARTHROSIS; OSTEONECROSIS; EFFICACY; BODY;
D O I
10.1007/s00256-020-03437-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To evaluate the efficacy of a new technique of percutaneous vertebral augmentation (PVA): drill rotation-cement injected under vacuum aspiration (DR-CIVAS) for vertebral compression fractures (OVCFs) with intravertebral vacuum cleft (IVC) sign. Materials and methods A retrospective study was conducted in 46 consecutive patients with OVCFs and IVC signs, who underwent PVA using DR-CIVAS (n = 22, DR-CIVAS group) or traditional technique without DR-CIVAS (n = 24, control group). The pre- and postoperative vertebral height and wedge angle change and visual analog scale (VAS), the volume of cement injected, incidences of cement leakage, and subsequent new vertebral compression fractures were evaluated between the two groups. Results No significant difference was found in cement leakage incidences, pre- and postoperative VAS scores, vertebral height, and wedge angle change between the two groups. The mean cement volume was significantly higher (P < 0.001) in DR-CIVAS group (4.87 mL) than in the control group (3.58 mL). Of the 22 patients in DR-CIVAS group, the subsequent fractures occurred in 2 cases (9.1%) located in the nonadjacent levels. In the control group, the subsequent fractures occurred in 6 cases (25.0%) located in the adjacent level (n = 1) and the augmented levels (n = 5). Although DR-CIVAS group did not demonstrate a statistical reduction of the incidence of subsequent fractures (P = 0.25), the subgroup analysis revealed that subsequent fractures frequently involved the augmented level in the control group (P = 0.04). Conclusions PVA with DR-CIVAS technique is effective for OVCFs with IVC sign, with lower incidences of subsequent new vertebral compression fractures in the augmented vertebra.
引用
收藏
页码:1459 / 1465
页数:7
相关论文
共 50 条
  • [1] Percutaneous vertebral augmentation using drill rotation for osteoporotic vertebral compression fractures with intravertebral vacuum cleft
    Min Li
    Yue Zhang
    Peng Jin
    Pu Jia
    Xun-wei Liu
    Hai Tang
    Gang Sun
    Skeletal Radiology, 2020, 49 : 1459 - 1465
  • [2] Percutaneous balloon kyphoplasty of osteoporotic vertebral compression fractures with intravertebral cleft
    Bao Chen
    Shunwu Fan
    Fengdong Zhao
    Indian Journal of Orthopaedics, 2014, 48 : 53 - 59
  • [3] Percutaneous balloon kyphoplasty of osteoporotic vertebral compression fractures with intravertebral cleft
    Chen, Bao
    Fan, Shunwu
    Zhao, Fengdong
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (01) : 53 - 59
  • [4] Osteoporotic vertebral compression fractures with an intravertebral cleft treated by percutaneous balloon kyphoplasty
    Wang, G.
    Yang, H.
    Chen, K.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (11): : 1553 - 1557
  • [5] Leakage of polymethylmethacrylate in percutaneous vertebroplasty: Comparison of osteoporotic vertebral compression fractures with and without an intravertebral vacuum cleft
    Jung, Jee Young
    Lee, Min Hee
    Ahn, Joong Mo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (03) : 501 - 506
  • [6] OSTEOPOROTIC VERTEBRAL COMPRESSION FRACTURES WITH INTRAVERTEBRAL VACUUM PHENOMENON
    KOEGER, AC
    CHAIBI, P
    ROZENBERG, S
    ROCHE, B
    BOURGEOIS, P
    ARTHRITIS AND RHEUMATISM, 1993, 36 (09): : S120 - S120
  • [7] The therapeutic effects of percutaneous kyphoplasty on osteoporotic vertebral compression fractures with or without intravertebral cleft
    Li, Zhe
    Liu, Tie
    Yin, Peng
    Wang, Yu
    Liao, Shengen
    Zhang, Shuo
    Su, Qingjun
    Hai, Yong
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (02) : 359 - 365
  • [8] The therapeutic effects of percutaneous kyphoplasty on osteoporotic vertebral compression fractures with or without intravertebral cleft
    Zhe Li
    Tie Liu
    Peng Yin
    Yu Wang
    Shengen Liao
    Shuo Zhang
    Qingjun Su
    Yong Hai
    International Orthopaedics, 2019, 43 : 359 - 365
  • [9] Intravertebral clefts in osteoporotic vertebral compression fractures
    McKiernan, F
    Faciszewski, T
    ARTHRITIS AND RHEUMATISM, 2003, 48 (05): : 1414 - 1419
  • [10] Percutaneous Vertebroplasty for Vertebral Compression Fractures with Intravertebral Cleft: Cement Injection under Vacuum Aspiration
    Koike, Yuya
    Takizawa, Kenji
    Ogawa, Yukihisa
    Fujikawa, Atsuko
    Yoshimatsu, Misako
    Nakajima, Yasuo
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (12) : 1721 - 1726