Percutaneous Balloon-Expandable Stent Graft Repair of a Ruptured Iliac Aneurysm

被引:0
|
作者
Cookson, Daniel [1 ,2 ]
Raza, Zahid [3 ]
机构
[1] Middlemore Hosp, Dept Radiol, Auckland 1640, New Zealand
[2] Royal Infirm Edinburgh NHS Trust, Dept Radiol, Edinburgh, Midlothian, Scotland
[3] Royal Infirm Edinburgh NHS Trust, Dept Vasc Surg, Edinburgh, Midlothian, Scotland
关键词
acute stent grafting; iliac aneurysm; ruptured posttraumatic aneurysm; ARTERY ANEURYSMS; ENDOVASCULAR MANAGEMENT; OPTIONS;
D O I
10.1177/1538574411407086
中图分类号
R61 [外科手术学];
学科分类号
摘要
Elective stent graft repair of iliac aneurysm is successful and safe. There are, however, few published data on stent grafting unstable patients with acute iliac aneurysm rupture. Iliac diameter mismatch can also present a challenge to emergency endovascular treatment. We report the treatment of an unstable patient with iliac aneurysm rupture and diameter mismatch using a percutaneous balloon-expandable polytetrafluoroethylene (PTFE) stent graft. Outcomes were satisfactory up to 12-month follow-up. Treatment of iliac aneurysm rupture using a balloon-expandable stent graft can be successful in selected patients. A percutaneous approach and targeted stent graft postdilatation enable prompt repair in the presence of diameter mismatch, facilitating emergency therapy.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 50 条
  • [31] PERCUTANEOUS TREATMENT OF EXTRACRANIAL CAROTID ATHEROSCLEROTIC DISEASE WITH BALLOON-EXPANDABLE STENT PLACEMENT
    YADAV, SS
    ROUBIN, GS
    IYER, SS
    VITEK, J
    KING, P
    INAMPUDI, C
    PLYUSHCHEVA, N
    LEVINE, RL
    DOBLAR, D
    MOUNTZ, J
    SUTOR, C
    JAIN, S
    CIRCULATION, 1995, 92 (08) : 107 - 107
  • [32] Cross-over Deployment of a Tapered Stent Graft to Repair a Ruptured Isolated Internal Iliac Aneurysm
    Lacquemanne, Jules
    Danut, Dan
    Allain, Charlotte
    Steinmetz, Eric
    ANNALS OF VASCULAR SURGERY, 2021, 74 : 522.e1 - 522.e5
  • [33] Percutaneous stent-graft for treatment of isolated iliac aneurysm
    Bhargava, B
    Sharma, S
    Agarwal, R
    Manchanda, SC
    TEXAS HEART INSTITUTE JOURNAL, 1998, 25 (03) : 220 - 221
  • [34] Design optimization of balloon-expandable coronary stent
    Li, Hongxia
    Wang, Xicheng
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2013, 48 (04) : 837 - 847
  • [35] Design optimization of balloon-expandable coronary stent
    Hongxia Li
    Xicheng Wang
    Structural and Multidisciplinary Optimization, 2013, 48 : 837 - 847
  • [36] Interventional retrieval of a balloon-expandable stent in an infant following tetralogy of Fallot repair
    Kuzma, Jacek
    Buczynski, Michal
    Emam, Mohamed Sameh
    Madry, Wojciech
    Kusmierczyk, Mariusz
    POLISH HEART JOURNAL-KARDIOLOGIA POLSKA, 2024, 82 (09): : 907 - 908
  • [37] VASCULAR OCCLUSION WITH A BALLOON-EXPANDABLE STENT OCCLUDER
    MOSS, JG
    LABORDE, JC
    CLEM, MC
    RIVERA, FJ
    ENCARNACION, CE
    MEYER, KB
    PALMAZ, JC
    RADIOLOGY, 1994, 191 (02) : 483 - 486
  • [38] Midterm outcomes of the Viabahn VBX balloon-expandable covered stent for fenestrations during complex endovascular aortic aneurysm repair
    Pavarino, Felipe L.
    V. Figueroa, Andres
    Tanenbaum, Mira T.
    Pizano, Alejandro
    Porras-Colon, Jesus
    Baig, Mirza S.
    Kirkwood, Melissa
    Timaran, Carlos H.
    JOURNAL OF VASCULAR SURGERY, 2025, 81 (01) : 38 - 45
  • [39] Balloon-expandable stent deformation during deployment into the iliac artery: a procedural complication managed conservatively
    Hamdan, M. F.
    Maguire, B. G.
    Walker, M. A.
    VASCULAR, 2012, 20 (04) : 233 - 235
  • [40] First results after placement of the new balloon-expandable Bridge™-stent into iliac arteries.
    Müller-Hülsbeck, S
    Grimm, J
    Jahnke, T
    Brossmann, J
    Hilbert, C
    Heller, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (10): : 836 - 841