Low energy recoil detection with a spherical proportional counter

被引:20
|
作者
Savvidis, I. [1 ]
Katsioulas, I. [1 ,2 ]
Eleftheriadis, C. [1 ]
Giomataris, I. [2 ]
Papaevangellou, T. [2 ]
机构
[1] Aristotle Univ Thessaloniki, Thessaloniki, Greece
[2] Univ Paris Saclay, IRFU, CEA, F-91191 Gif Sur Yvette, France
关键词
Nuclear recoil detection; WIMP detection; Neutrino detection; Spherical proportional counter; Quenching factor; 4.438 MEV GAMMA; RATIO;
D O I
10.1016/j.nima.2017.09.014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present results for the detection of low energy nuclear recoils in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC). An Am-241-Be-9 fast neutron source is used in order to obtain neutron-nucleus elastic scattering events inside the gaseous volume of the detector. The detector performance in the keV energy region was measured by observing the 5.9 keV line of a Fe-55 X-ray source, with energy resolution of 10% (sigma). The toolkit GEANT4 was used to simulate the irradiation of the detector by an Am-241-Be-9 source, while SRIM was used to calculate the Ionization Quenching Factor (IQF), the simulation results are compared with the measurements. The potential of the SPC in low energy recoil detection makes the detector a good candidate for a wide range of applications, including Supernova or reactor neutrino detection and Dark Matter (WIMP) searches (via coherent elastic scattering). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:220 / 226
页数:7
相关论文
共 50 条
  • [31] Characterisation of spherical recoil proton proportional counters used for neutron spectrometry
    Pichenot, G
    Guldbakke, S
    Asselineau, B
    Gressier, V
    Itié, C
    Klein, H
    Knauf, K
    Lebreton, L
    Löb, S
    Pochon-Guérin, L
    Schlegel, D
    Sosaat, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 165 - 169
  • [32] Detection of radon by means of a proportional counter
    Brown, SC
    Elliott, LG
    Evans, RD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1942, 13 (04): : 147 - 151
  • [33] USE OF A PROPORTIONAL COUNTER FOR MESON DETECTION
    POLLARD, EC
    PHYSICAL REVIEW, 1946, 69 (11-1): : 689 - 689
  • [34] Proportional counter amplification at low voltages
    Rose, ME
    Ramsey, WE
    PHYSICAL REVIEW, 1942, 61 (7/8): : 504 - 509
  • [35] LOW LEVEL PROPORTIONAL COUNTER FOR TRITIUM
    CHARALAMBUS, S
    GOEBEL, K
    NUCLEAR INSTRUMENTS & METHODS, 1963, 25 (01): : 109 - 117
  • [36] SMALL, LOW BACKGROUND PROPORTIONAL COUNTER
    WILLIAMSON, FO
    ZIMMERMANN, HU
    NUCLEAR INSTRUMENTS & METHODS, 1978, 148 (02): : 231 - 234
  • [37] PULSE-HEIGHT DISTRIBUTION IN LOW-ENERGY PROPORTIONAL COUNTER MEASUREMENTS
    BREYER, B
    NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (1-2): : 91 - 93
  • [38] MULTIWIRE PROPORTIONAL COUNTER TECHNIQUE FOR STANDARDIZATION OF LOW-ENERGY PHOTON SOURCES
    CHEW, WM
    MCGEORGE, JC
    FINK, RW
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (03): : 499 - 501
  • [39] MULTI-WIRE PROPORTIONAL COUNTER SYSTEM FOR LOW ENERGY NUCLEAR PHYSICS
    GABITZSC.N
    RENDIC, D
    PHILLIPS, GC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (04): : 581 - &
  • [40] Investigation of the possibility of γ-background discrimination in a neutron spectrometer with a proportional counter of recoil protons
    Shvetsov A.M.
    Vinogradov Yu.I.
    Vikhlyantsev O.P.
    Kuryakin A.V.
    Bulletin of the Russian Academy of Sciences: Physics, 2007, 71 (12) : 1748 - 1752