A MODEL EXPERIMENT OF A DOUBLE-CONE TARGET USING A GAP TARGET

被引:1
|
作者
Sakawa, Y. [1 ]
Nakamura, H. [1 ]
Oshima, S. [1 ]
Hatakeyama, M. [2 ]
Kageiwa, N. [2 ]
Hino, S. [2 ]
Tanimoto, S. [2 ]
Tanabe, M. [2 ]
Habara, H. [2 ]
Homma, H. [1 ]
Norimatsu, T. [1 ]
Jitsuno, T. [1 ]
Cai, H. [1 ]
Zhou, W. [2 ]
Johzaki, T. [1 ]
Sunahara, A. [3 ]
Nagatomo, H. [1 ]
Nishimura, H. [1 ]
Tanaka, K. A. [1 ,2 ]
Mima, K. [1 ]
Azechi, H. [1 ]
机构
[1] Osaka Univ, Inst Laser Engn, 2-6 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Engn, Suita, Osaka 5650871, Japan
[3] Inst Laser Technol, Suita, Osaka 5650871, Japan
关键词
D O I
10.1088/1742-6596/244/4/042012
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
We have conducted preliminary experiments to prove the vacuum-shielding effect using an Al-Cu double-foil (both Al and Cu foils are 1 mm x 1 mm x 10 mu mt) target with a vacuum-gap. Particle-in-cell simulation results have shown that the double-cone confines the electrons for hundreds of femtoseconds by the sheath electric field inside the vacuum-gap [ T. Nakamura, et al., Phys. Plasmas 14, 103105 (2007)]. Cu-K alpha intensity decreased with the vacuum-gap, i.e., the number of fast electrons that reached the Cu foil decreased with the gap. In the stack measurement, the number of electrons detected in the target surface direction increased with the gap. These results indicate that when the double-cone target is used, fast electrons created by an ignition laser can be reflected from the vacuum-gap, move along the cone surface, and be transferred towards the cone tip.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Characterizing off-target corticospinal responses to double-cone transcranial magnetic stimulation
    Proessl, F.
    Canino, M. C.
    Beckner, M. E.
    Sinnott, A. M.
    Eagle, S. R.
    LaGoy, A. D.
    Conkright, W. R.
    Sterczala, A. J.
    Connaboy, C.
    Ferrarelli, F.
    Germain, A.
    Nindl, B. C.
    Flanagan, S. D.
    EXPERIMENTAL BRAIN RESEARCH, 2021, 239 (04) : 1099 - 1110
  • [2] Characterizing off-target corticospinal responses to double-cone transcranial magnetic stimulation
    F. Proessl
    M. C. Canino
    M. E. Beckner
    A. M. Sinnott
    S. R. Eagle
    A. D. LaGoy
    W. R. Conkright
    A. J. Sterczala
    C. Connaboy
    F. Ferrarelli
    A. Germain
    B. C. Nindl
    S. D. Flanagan
    Experimental Brain Research, 2021, 239 : 1099 - 1110
  • [3] The impact of target parameters on the collision process and hot-spot performance in the double-cone ignition scheme
    Fang, K.
    Gu, H. C.
    Zhang, Y. H.
    Dong, Y. F.
    Zhang, C. L.
    Dai, Y.
    Zhao, X.
    Zhang, Z.
    Yuan, X. H.
    Li, Y. T.
    Zhang, J.
    PHYSICS OF PLASMAS, 2025, 32 (03)
  • [4] DOUBLE-CONE MIXERS IN POLAND
    BARANSKI, R
    BACKER UND KONDITOR, 1978, 32 (03): : 83 - 85
  • [5] The Ostwald colour double-cone
    Meissner, O
    ZEITSCHRIFT FUR PHYSIK, 1924, 21 : 68 - 72
  • [6] REINFORCEMENT OF SUBGRADE DOUBLE-CONE PILES
    Degtyar, A. A.
    Burgonutdinov, A. M.
    RUSSIAN JOURNAL OF BUILDING CONSTRUCTION AND ARCHITECTURE, 2021, (02): : 62 - 73
  • [7] Enhanced mixing in double-cone blenders
    Brone, D
    Muzzio, FJ
    POWDER TECHNOLOGY, 2000, 110 (03) : 179 - 189
  • [8] Quantitative assessment of double-cone seal leakage in canned reactor coolant pump based on double-cone ring stress
    Wang, Hanbo
    Wang, Xiufeng
    Chen, Zhi
    Zhao, Xuecen
    Wang, Haiyang
    MEASUREMENT, 2025, 240
  • [9] STUDIES ON SOLIDS MIXING IN A DOUBLE-CONE BLENDER
    SETHURAMAN, KJ
    DAVIES, GS
    POWDER TECHNOLOGY, 1972, 5 (02) : 115 - +
  • [10] Entanglement entropy via double-cone regularization
    Kawamoto, Taishi
    Suzuki, Yu-ki
    PHYSICAL REVIEW D, 2024, 110 (04)