A Randomized, Multicenter, Single-Blinded Trial Comparing Paclitaxel-Coated Balloon Angioplasty With Plain Balloon Angioplasty in Drug-Eluting Stent Restenosis The PEPCAD-DES Study

被引:271
|
作者
Rittger, Harald [1 ]
Brachmann, Johannes [2 ]
Sinha, Anil-M. [3 ]
Waliszewski, Matthias [4 ]
Ohlow, Marc [5 ]
Brugger, Andreas [6 ]
Thiele, Holger [7 ]
Birkemeyer, Ralf [8 ]
Kurowski, Volkhard [9 ]
Breithardt, Ole-A. [1 ]
Schmidt, Martin [10 ]
Zimmermann, Stefan [1 ]
Lonke, Sandra [1 ]
von Cranach, Moritz [1 ]
The-Vinh Nguyen [11 ]
Daniel, Werner G. [1 ]
Woehrle, Jochen [11 ]
机构
[1] Univ Klinikum Erlangen, Med Klin 2, D-91054 Erlangen, Germany
[2] Klinikum Coburg, Med Klin 2, Coburg, Germany
[3] Klinikum Hof, Kardiol Klin, Hof, Germany
[4] B Braun Vasc Syst, Melsungen, Germany
[5] Zentralklinikum Bad Berka, Kardiol Klin, Bad Berka, Germany
[6] Klinikum Kulmbach, Kardiol Klin, Kulmbach, Germany
[7] Univ Leipzig, Herzzentrum, Klin Innere Med Kardiol, Leipzig, Germany
[8] Schwarzwald Baar Klinikum Villingen Schwenningen, Villingen Schwenningen, Germany
[9] Univ Klinikum Lubeck, Med Klin 2, Lubeck, Germany
[10] Stadt Klinikum Munchen Bogenhausen, Kardiol Klin, Munich, Germany
[11] Univ Ulm, Dept Internal Med Cardiol 2, Ulm, Germany
关键词
balloon angioplasty; drug-coated balloon; drug-eluting stent; in-stent restenosis; FOLLOW-UP; THROMBOSIS; CATHETER; OUTCOMES;
D O I
10.1016/j.jacc.2012.01.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to define the impact of paclitaxel-coated balloon angioplasty for treatment of drug-eluting stent restenosis compared with uncoated balloon angioplasty alone. Background Drug-coated balloon angioplasty is associated with favorable results for treatment of bare-metal stent restenosis. Methods In this prospective, single-blind, multicenter, randomized trial, the authors randomly assigned 110 patients with drug-eluting stent restenoses located in a native coronary artery to paclitaxel-coated balloon angioplasty or uncoated balloon angioplasty. Dual antiplatelet therapy was prescribed for 6 months. Angiographic follow-up was scheduled at 6 months. The primary endpoint was late lumen loss. The secondary clinical endpoint was a composite of cardiac death, myocardial infarction attributed to the target vessel, or target lesion revascularization. Results There was no difference in patient baseline characteristics or procedural results. Angiographic follow-up rate was 91%. Treatment with paclitaxel-coated balloon was superior to balloon angioplasty alone with a late loss of 0.43 +/- 0.61 mm versus 1.03 +/- 0.77 mm (p < 0.001), respectively. Restenosis rate was significantly reduced from 58.1% to 17.2% (p < 0.001), and the composite clinical endpoint was significantly reduced from 50.0% to 16.7% (p < 0.001), respectively. Conclusions Paclitaxel-coated balloon angioplasty is superior to balloon angioplasty alone for treatment of drug-eluting stent restenosis. (PEPCAD DES-Treatment of DES-In-Stent Restenosis With SeQuent (R) Please Paclitaxel Eluting PTCA Catheter [PEPCAD-DES]; NCT00998439) (J Am Coll Cardiol 2012;59:1377-82) (C) 2012 by the American College of Cardiology Foundation
引用
收藏
页码:1377 / 1382
页数:6
相关论文
共 50 条
  • [21] Quantitative Optical Coherence Tomographic Findings After Paclitaxel-coated Balloon Angioplasty for Drug-eluting Stent Restenosis
    Miura, Katsuya
    Tada, Takeshi
    Shimada, Takenobu
    Ohya, Masanobu
    Amano, Hidewo
    Kubo, Shunsuke
    Hyodo, Yusuke
    Seiji, Habara
    Goto, Tsuyoshi
    Kadota, Kazushige
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (16) : S48 - S48
  • [22] Is Cutting Balloon Angioplasty More Useful Than Plain Balloon Angioplasty for the Treatment of Drug-Eluting Stent Restenosis?
    Park, Seung-Jung
    Oh, Il-Young
    Shin, Dong-Ho
    Park, Kyung-Woo
    Lee, Hae-Young
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Kim, Hyo-Soo
    CIRCULATION, 2009, 120 (18) : S914 - S915
  • [23] Early and late restenosis after excimer laser coronary angioplasty and paclitaxel-coated balloon combination therapy for drug-eluting stent restenosis
    Higaki, T.
    Nishioka, K.
    Suruga, K.
    Takemoto, H.
    Nakano, T.
    Hashimoto, Y.
    Tomomori, S.
    Oi, K.
    Dai, K.
    Kawase, T.
    Nakama, Y.
    Suenari, K.
    Otsuka, M.
    Masaoka, Y.
    Shiode, N.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1645 - 1645
  • [24] Impact of Stent Size on the Cause of Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis: Optical Coherence Tomography Study.
    Miura, Katsuya
    Tada, Takeshi
    Murai, Ryosuke
    Ohya, Masanobu
    Shimada, Takenobu
    Amano, Hidewo
    Kubo, Shunsuke
    Otsuru, Suguru
    Seiji, Habara
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Kadota, Kazushige
    CIRCULATION, 2018, 138
  • [25] Neoatherosclerosis After Paclitaxel-Coated Balloon Angioplasty for In-Stent Restenosis
    Alfonso, Fernando
    Jimenez-Quevedo, Pilar
    Gonzalo, Nieves
    Medina, Miguel
    Banuelos, Camino
    CIRCULATION, 2014, 129 (08) : 923 - 925
  • [26] EFFECTIVENESS OF PACLITAXEL-COATED BALLOON ANGIOPLASTY FOR DRUG-ELUTING STENT RESTENOSIS IN THE LEFT MAIN CORONARY ARTERY 1301-009
    Takamatsu, Makoto
    Sano, Arata
    Osakada, Kohei
    Hata, Reo
    Kuwayama, Akimune
    Murai, Ryosuke
    Miura, Katsuya
    Ohya, Masanobu
    Shimada, Takenobu
    Amano, Hidewo
    Kubo, Shunsuke
    Ozaki, Masatomo
    Yoshino, Mituru
    Miyake, Koshi
    Kawase, Yuichi
    Ohashi, Noriyuki
    Tasaka, Hiroshi
    Habara, Seiji
    Tanaka, Hiroyuki
    Maruo, Takeshi
    Fuku, Yasushi
    Katoh, Harumi
    Goto, Tsuyoshi
    Kadota, Kazushige
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1366 - 1366
  • [27] Long-term Outcomes of Repeated Paclitaxel-coated Balloon Angioplasty for Recurrent Restenosis Lesions after Paclitaxel-coated Balloon Angioplasty for In-stent Restenosis
    Iwasaki, Keiichiro
    Kadota, Kazushige
    Kuwayama, Akimune
    Miura, Katsuya
    Ohya, Masanobu
    Shimada, Takenobu
    Kubo, Shunsuke
    Hyodo, Yusuke
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B159 - B160
  • [28] A multicenter randomized comparison of paclitaxel-coated balloon with plain balloon angioplasty in patients with small vessel disease
    Atsushi Funatsu
    Shigeru Nakamura
    Naoto Inoue
    Shinsuke Nanto
    Masato Nakamura
    Masashi Iwabuchi
    Kenji Ando
    Ryuta Asano
    Seiji Habara
    Shigeru Saito
    Ken kozuma
    Kazuaki Mitsudo
    Clinical Research in Cardiology, 2017, 106 : 824 - 832
  • [29] Is Cutting Balloon Angioplasty more useful than Plain Balloon Angioplasty for the Treatment of Drug-Eluting Stent Restenosis versus Bare Metal Stent Restenosis?
    Park, Seung-Jung
    Oh, Il-Young
    Shin, Dong-Ho
    Park, Kyung-Woo
    Lee, Hae-Young
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Kim, Hyo-Soo
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 193D - 194D
  • [30] A multicenter randomized comparison of paclitaxel-coated balloon with plain balloon angioplasty in patients with small vessel disease
    Funatsu, Atsushi
    Nakamura, Shigeru
    Inoue, Naoto
    Nanto, Shinsuke
    Nakamura, Masato
    Iwabuchi, Masashi
    Ando, Kenji
    Asano, Ryuta
    Habara, Seiji
    Saito, Shigeru
    Kozuma, Ken
    Mitsudo, Kazuaki
    CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (10) : 824 - 832