Fundamental frequency switching strategy for grid-connected cascaded H-bridge multilevel inverter to mitigate voltage harmonics at the point of common coupling

被引:10
|
作者
Hajizadeh, Mehdi [1 ]
Fathi, Seyed Hamid [1 ]
机构
[1] Amirkabir Univ Technol, Dept Elect Engn, Power Elect & Drives Res Lab, 424 Hafez Ave, Tehran 15914, Iran
关键词
invertors; distributed power generation; reactive power; genetic algorithms; fundamental frequency switching strategy; grid-connected cascaded H-bridge multilevel inverter; voltage harmonics; point of common coupling; isolated dc sources; distributed generation sources; interface inverter; reactive power exchange; voltage quality; coupling impedance; genetic algorithm optimisation; modified switching method; ELIMINATION; ALGORITHM;
D O I
10.1049/iet-pel.2015.0970
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cascaded H-bridge multilevel inverter with isolated dc sources is a suitable choice as an interface between grid and distributed generation (DG) sources. The main duty of the interface inverter is to adapt voltage of the grid and DG source while active and reactive power exchange is also controlled by it. Conventional fundamental frequency switching methods have been studied so far only for quality improvement of the inverter output voltage. However, for the grid-connected applications, voltage quality at the point of common coupling (PCC) is more important than the inverter output voltage. This study presents a modified harmonic mitigation fundamental frequency switching method for the grid-connected cascaded H-bridge multilevel inverters. The goal is to calculate optimum switching angles of the inverter which satisfy the standard limits for the total harmonic distortion and harmonic contents of the voltage waveform at PCC considering specifications of the grid. This is also to be achieved with minimum required amount of the coupling impedance. Genetic algorithm optimisation program based on the modified switching method is employed for a sample system including a three-phase cascaded H-bridge seven-level inverter connected to a harmonic polluted grid. Computer simulation using Simulink/MATLAB is performed, the results of which confirm effectiveness of the proposed method.
引用
收藏
页码:2387 / 2393
页数:7
相关论文
共 50 条
  • [41] Control and application of grid-connected cascaded h-bridge pv inverters
    Selvaraj J.
    Amir A.
    Amir A.
    Rahim N.A.
    Renewable Energy and Power Quality Journal, 2020, 18 : 30 - 35
  • [42] Control of Grid Connected Cascaded H-Bridge Multilevel Converter During Grid Voltage Unbalance for Photovoltaic Application
    Morya, Ajay Kumar
    Shukla, Anshuman
    Doolla, Suryanarayana
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 7990 - 7995
  • [43] Decoupled Active and Reactive Power Control of Cascaded H-Bridge PV Inverter for Grid-Connected Applications
    Sridhar, V.
    Umashankar, S.
    Sanjeevikumar, P.
    ADVANCES IN SMART GRID AND RENEWABLE ENERGY, 2018, 435 : 315 - 323
  • [44] Performance Evaluation of Cascaded H-bridge Multilevel Grid-Connected Converter with Model Predictive Control Technique
    Hosseinzadeh, Mohammad Ali
    Sarbanzadeh, Maryam
    Salehi, Ali
    Rivera, Marco
    Munoz, Javier
    Wheeler, Patrick
    2019 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2019, : 1806 - 1811
  • [45] Efficiency Improved and Current Balanced Three-Phase Modular Cascaded H-Bridge Multilevel PV Inverter for Grid-Connected Applications
    Xiao, Bailu
    Tolbert, Leon M.
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 4661 - 4669
  • [46] Finite-Control-Set Model Predictive Control for Asymmetrical Cascaded H-Bridge Multilevel Grid-Connected Inverter with Flying Capacitor
    Han, Jingang
    Liu, Liang
    Yao, Gang
    Tang, Tianhao
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 16 (10) : 1328 - 1335
  • [47] Understanding the Staircase Modulation Strategy and Its Application in Both Isolated and Grid-Connected Asymmetric Cascaded H-Bridge Multilevel Inverters
    Curi Busarello, Tiago Davi
    de Sousa Marcondes Reuter, Andre Luiz
    Peres, Adriano
    Simoes, Marcelo Godoy
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (05) : 5371 - 5382
  • [48] Bifurcation Analysis in a Digitally Controlled H-Bridge Grid-Connected Inverter
    Lei, Bo
    Xiao, Guochun
    Wu, Xuanlv
    Kafle, Yuba-Raj
    Zheng, Lifu
    INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 2014, 24 (01):
  • [49] Optimized switching scheme of cascaded H-bridge multilevel inverter using PSO
    Gupta, Vivek Kumar
    Mahanty, R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 64 : 699 - 707
  • [50] Output Voltage Control of Single Phase Reduced Switch Cascaded H-bridge Multilevel Inverter with Constant Switching Frequency Operation
    Chakrabarty, Ramyani
    Adda, Ravindranath
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 4115 - 4120