Evaluation of intracranial artery stenosis using time-of-flight magnetic resonance angiography: new wine in an old bottle

被引:5
|
作者
Shao, Sai [1 ]
Sun, Qinjian [2 ]
机构
[1] Shandong First Med Univ, Shandong Prov Hosp, Dept Radiol, 324 Jingwu Weiqi Rd, Jinan 250021, Shandong, Peoples R China
[2] Shandong First Med Univ, Shandong Prov Hosp, Dept Neurol, 324 Jingwu Weiqi Rd, Jinan 250021, Shandong, Peoples R China
关键词
Intracranial Arteriosclerosis; Magnetic Resonance Angiography; Diagnosis; ATHEROSCLEROSIS; STROKE;
D O I
10.1007/s00330-021-08521-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Key Points TOF MRA is very important in the evaluation of cerebrovascular stenosis, and a novel evaluation system can further enhance its strengths. This evaluation system is more accurate based on the fact that cerebral vascular stenosis alters hemodynamics and leads to different imaging presentations.
引用
收藏
页码:3670 / 3671
页数:2
相关论文
共 50 条
  • [31] Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils
    Westerlaan, HE
    van der Vliet, AM
    Hew, JM
    Meiners, LC
    Metzemaekers, JDM
    Mooij, JJA
    Oudkerk, M
    NEURORADIOLOGY, 2005, 47 (08) : 622 - 629
  • [32] Spiral time-of-flight magnetic resonance angiography for intracranial vascular imaging: performance compared to conventional Cartesian angiogram
    Xu, Lina
    Wu, Jian
    Kang, Taishan
    Lin, Liangjie
    Lv, Shaomao
    Lin, Jianzhong
    Feng, Zhipeng
    Cai, Congbo
    Chen, Zhong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (05) : 3417 - 3431
  • [33] Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils
    H. E. Westerlaan
    A. M. van der Vliet
    J. M. Hew
    L. C. Meiners
    J. D. M. Metzemaekers
    J. J. A. Mooij
    M. Oudkerk
    Neuroradiology, 2005, 47 : 622 - 629
  • [34] Time-of-flight MR angiography of carotid artery stenosis: Does a flow void represent severe stenosis?
    Nederkoorn, PJ
    van der Graaf, Y
    Eikelboom, BC
    van der Lugt, A
    Bartels, LW
    Mali, WPTM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (10) : 1779 - 1784
  • [35] Flow voids in time-of-flight MR angiography of carotid artery stenosis? It depends on the TE!
    Lev, MH
    Romero, JM
    Gonzalez, RG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (10) : 2120 - 2120
  • [36] 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY USING SPIN SATURATION
    DUMOULIN, CL
    CLINE, HE
    SOUZA, SP
    WAGLE, WA
    WALKER, MF
    MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) : 35 - 46
  • [37] Compressed sensing time-of-flight magnetic resonance angiography with high spatial resolution for evaluating intracranial aneurysms: comparison with digital subtraction angiography
    Kim, Donghyun
    Heo, Young Jin
    Jeong, Hae Woong
    Baek, Jin Wook
    Shin, Gi Won
    Jin, Sung-Chul
    Baek, Hye Jin
    Ryu, Kyeong Hwa
    Kim, Kang Soo
    Kim, InSeong
    NEURORADIOLOGY JOURNAL, 2021, 34 (03): : 213 - 221
  • [38] Three-Dimensional Time-of-Flight Magnetic Resonance Angiography of Intracranial Vessels in a Canine Model of Ischemic Stroke with Permanent Occlusion of the Middle Cerebral Artery
    Kang, Byeong-Teck
    Jang, Dong-Pyo
    Gu, Su-Hyun
    Kim, Young-Bo
    Lim, Chae-Young
    Lee, Jong-Hwan
    Woo, Eung-Je
    Cho, Zang-Hee
    Park, Hee-Myung
    COMPARATIVE MEDICINE, 2009, 59 (01) : 72 - 77
  • [39] Highly accelerated time-of-flight magnetic resonance angiography using spiral imaging improves conspicuity of intracranial arterial branches while reducing scan time
    Tobias Greve
    Nico Sollmann
    Andreas Hock
    Silke Hey
    Velmurugan Gnanaprakasam
    Marco Nijenhuis
    Claus Zimmer
    Jan S. Kirschke
    European Radiology, 2020, 30 : 855 - 865
  • [40] Highly accelerated time-of-flight magnetic resonance angiography using spiral imaging improves conspicuity of intracranial arterial branches while reducing scan time
    Greve, Tobias
    Sollmann, Nico
    Hock, Andreas
    Hey, Silke
    Gnanaprakasam, Velmurugan
    Nijenhuis, Marco
    Zimmer, Claus
    Kirschke, Jan S.
    EUROPEAN RADIOLOGY, 2020, 30 (02) : 855 - 865