Macular hole surgery with air tamponade

被引:0
|
作者
Gesser, C. [1 ]
Eckert, T. [1 ]
Eckardt, U. [1 ]
Porkert, U. [1 ]
Eckardt, C. [1 ]
机构
[1] Stadt Kliniken Frankfurt Hochst, Augenklin, D-65929 Frankfurt, Germany
来源
OPHTHALMOLOGE | 2010年 / 107卷 / 11期
关键词
Macular hole; Air tamponade; Prone positioning; Bridge formation; Optical coherence tomography (OCT); FACE; DURATION; OUTCOMES; GAS;
D O I
10.1007/s00347-010-2171-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We used a specially designed optical coherence tomography (OCT) device to investigate the dynamics of early macular hole closure after vitrectomy with air tamponade and to determine the closure rate and the briefest possible prone positioning. A total of 112 patients with macular holes were examined using a modified spectral-domain OCT on days 1, 2 and 3 after vitrectomy with air tamponade. As soon as closure was complete (group one) or partial (hole closed at inner retinal layers but outer retinal layers still detached from pigment epithelial layer, group two), prone positioning was ended. If neither partial nor complete closure was observed by the third day, renewed vitrectomy was performed on postoperative days 4-8. Macular hole closure was achieved in 88 of the 112 eyes (79%). In 35 of the 88 eyes partial closure was noted on the first postoperative day. In 20 of the 24 eyes requiring renewed surgery the hole was finally closed. After a median follow-up of 144 days the macular hole was completely closed in all layers in 108 patients (96%). Mean visual acuity at final follow-up was 0.37 logMAR in group one, 0.29 logMAR in group two and 0.51 logMAR in patients whose holes closed after renewed surgery. Once closed, none of the macular holes reopened. The 79% initial closure rate in the present study is about 10% lower than that reported in other studies employing long-acting gas tamponades. However, renewed surgery with air tamponade achieved a closure rate of 96%. Early partial closure is sufficient for subsequent complete closure, requires no further tamponade or prolonged prone positioning, and has no negative effect on the functional results. Short-term prone positioning is sufficient for most patients.
引用
收藏
页码:1043 / +
页数:7
相关论文
共 50 条
  • [21] Macular hole surgery with air tamponade and optical coherence tomography-based duration of face-down positioning
    Eckardt, Claus
    Eckert, Tillmann
    Eckardt, Ute
    Porkert, Ute
    Gesser, Caroline
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (08): : 1087 - 1096
  • [22] The gas conundrum; which tamponade after surgery for full thickness macular hole?
    Cherubini, Sandro Di Simplicio
    Alexander, Philip
    Newsom, Richard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [23] The Gas Conundrum; Which Tamponade after Surgery for Full Thickness Macular Hole?
    Di Simplicio, Sandro
    Newsom, Richard
    Philip, Alexander
    OPHTHALMOLOGICA, 2016, 236 : 58 - 59
  • [24] Silicone oil vs. gas tamponade in macular hole surgery.
    Pham, CB
    Capone, A
    Siegner, SW
    Sternberg, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S690 - S690
  • [25] Outcomes of Light Silicone Oil Tamponade for Failed Idiopathic Macular Hole Surgery
    Nowroozzadeh, M. Hossein
    Ashraf, Hossein
    Zadmehr, Mehdi
    Farvardin, Mohsen
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (02) : 130 - 137
  • [26] Vitrectomy with sulfur hexafluoride versus air tamponade for idiopathic macular hole: a retrospective study
    Yuou Yao
    Huichao Yan
    Jinfeng Qu
    Chongya Dong
    Jianhong Liang
    Hong Yin
    Chi Ren
    Enzhong Jin
    Mingwei Zhao
    BMC Ophthalmology, 23
  • [27] Vitrectomy with sulfur hexafluoride versus air tamponade for idiopathic macular hole: a retrospective study
    Yao, Yuou
    Yan, Huichao
    Qu, Jinfeng
    Dong, Chongya
    Liang, Jianhong
    Yin, Hong
    Ren, Chi
    Jin, Enzhong
    Zhao, Mingwei
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [28] Macular hole surgey with silicone oil tamponade
    Akduman, L
    Oz, O
    Mehr, DS
    Feman, SS
    Olk, RJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U588 - U588
  • [29] Outcome of 2 cc pure sulfur hexafluoride gas tamponade for macular hole surgery
    Naresh B. Kannan
    Olukorede O. Adenuga
    Karthik Kumar
    Kim Ramasamy
    BMC Ophthalmology, 16
  • [30] Outcome of 2 cc pure sulfur hexafluoride gas tamponade for macular hole surgery
    Kannan, Naresh B.
    Adenuga, Olukorede O.
    Kumar, Karthik
    Ramasamy, Kim
    BMC OPHTHALMOLOGY, 2016, 16