Heating Characteristics of the Contact Wire for Circuit Breaker in Poor Contact

被引:0
|
作者
Lee, D. D. [1 ]
Lim, K. B. [2 ]
Kim, T. W. [3 ]
机构
[1] Hanbat Natl Univ, Dept Elect Engn, Daejeon 34158, South Korea
[2] Daejeon Inst Sci & Technol, Dept Fire & Safety Management, Daejeon 35408, South Korea
[3] Korea Elect Safety Corp, Elect Safety Res Inst, Jeollabuk Do 55365, South Korea
关键词
Electric Fire; Heating Characteristics; Poor Contact; Series Arc;
D O I
10.1166/asl.2017.8637
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electrical fire occurs due to various causes such as short circuit, overcurrent, poor contact, and tacking. In addition, when a fire from poor contact progresses, the coating of wire is damaged inducing secondary short circuit or ground, which could lead to complex electrical accidents. Therefore, in this study, to investigate the overload mechanism of an electrical fire due to the poor contact of the screw-type connector of a circuit breaker, the temperature characteristics, surface, and composition of the poor contact wire of the circuit breaker were analyzed depending on series arc, and the possibility as a method for electrical fire prevention was examined.
引用
收藏
页码:1491 / 1495
页数:5
相关论文
共 50 条
  • [21] Monitoring of HV Generator Circuit Breaker Contact Ablation Based on Acoustic Emission
    Ukil, Abhisek
    Zlatanski, Martin
    Hochlehnert, Moritz
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (10) : 2683 - 2693
  • [22] A System for Dynamic Contact Resistance with Arduino Platform on MV and HV Circuit Breaker
    de Souza, Ronimack Trajano
    de Arauejo, Jalberth Fernandes
    da Costa, Edson Guedes
    de Macedo, Euler C. T.
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 369 - 373
  • [23] Development of Contact Material Solutions for Low-Voltage Circuit Breaker Applications
    Muetzel, Timo
    Braumann, Peter
    Niederreuther, Ralf
    PROCEEDINGS OF THE FIFTY-SIXTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2010, : 142 - 147
  • [24] Influence of Eddy Current Effect on the Circuit Breaker Contact Mechanism Heat Loss
    Wang, Dayang
    Yao, Fang
    Li, Zhigang
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 943 - +
  • [25] Research on dynamic ablative behavior of contact during breaking of DC circuit breaker
    Guo, Ze
    Ma, Chuanjun
    Guo, Zixu
    Liu, Hang
    Chen, Xiangji
    AIP ADVANCES, 2025, 15 (02)
  • [26] A Test System for Moving Contact Motion Parameter of Circuit Breaker Based on PXI
    Ma, Li-Qiang
    Cao, Jing
    Zheng, Hui-Quan
    Wang, Tian-Zheng
    He, Meng-Yuan
    INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION (ICCA 2016), 2016, : 285 - 288
  • [27] Novel Hybrid Circuit Breaker Topology Using a Twin Contact Mechanical Switch
    Banihashemi, Farzad
    Beheshtaein, Siavash
    Cuzner, Robert
    2021 9TH INTERNATIONAL CONFERENCE ON SMART GRID, ICSMARTGRID, 2021, : 132 - 136
  • [28] Contact burn due to a heated-wire breathing circuit
    Lee, Wonjin
    Cho, Kwang Rae
    Lee, Jeong Han
    JOURNAL OF ANESTHESIA, 2014, 28 (05) : 802 - 802
  • [29] Theoretical Analysis and Calculation of Arc Contact Erosion of High Voltage Circuit Breaker
    Chen, Gong
    Cheng, Zhuang
    Duan, Tao
    Zeng, Weiwen
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 189 - 193
  • [30] The Design of the Vacuum Circuit Breaker Contact Quality Detection System Based on FPGA
    Yang, Shouliang
    Bao, Songjian
    Zeng, Linggang
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY III, PTS 1-3, 2013, 401 : 1514 - 1518