Fast spin-echo triple-echo Dixon (fTED) technique for efficient T2-weighted water and fat imaging

被引:41
|
作者
Ma, Jinafei
Son, Jong Bum
Zhou, Yuxiang
Le-Petross, Huong
Choi, Haesun
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[2] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
关键词
dixon imaging; fast spin echo; water and fat; fast triple-echo Dixon; parallel imaging;
D O I
10.1002/mrm.21268
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Previously published fast spin-echo (FSE) implementations of a Dixon method for water and fat separation all require multiple scans and thus a relatively long scan time. Further, the minimum echo spacing (esp), a time critical for FSE image quality and scan efficiency, often needs to be increased in order to bring about the required phase shift between the water and fat signals. This work proposes and implements a novel FSE triple-echo Dixon (fTED) technique that can address these limitations. In the new technique, three raw images are acquired in a single FSE scan by replacing each frequency-encoding gradient in a conventional FSE with three consecutive gradients of alternating polarity. The timing of the three gradients is adjusted by selecting an appropriate receiver bandwidth (RBW) so that the water and fat signals for the three corresponding echoes have a relative phase shift of -180 degrees, 0 degrees, and 180 degrees, respectively. A fully automated postprocessing algorithm is then used to generate separate water-only and fat-only images for each slice. The technique was implemented with and without parallel imaging. We demonstrate that the new fTED technique enables both uniform water/fat separation and fast scanning with uncompromised scan parameters, including applications such as T-2-weighted separate water and fat imaging of the abdomen during breath-holding. Magn Reson Med 58:103-109, 2007. (c) 2007 Wiley-Liss, Inc.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 50 条
  • [31] PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN
    SCHWARTZ, LH
    SELTZER, SE
    TEMPANY, CMC
    SILVERMAN, SG
    PIWNICAWORMS, DR
    ADAMS, DF
    HERMAN, L
    HERMAN, LT
    HOOSHMAND, R
    RADIOLOGY, 1993, 189 (02) : 411 - 416
  • [32] SEPARATION OF FAT AND WATER IN FAST SPIN-ECHO MR-IMAGING WITH THE 3-POINT DIXON TECHNIQUE
    HARDY, PA
    HINKS, RS
    TKACH, JA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 181 - 185
  • [33] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [34] Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver
    Altbach, MI
    Outwater, EK
    Trouard, TP
    Krupinski, EA
    Theilmann, RJ
    Stopeck, AT
    Kono, M
    Gmitro, AF
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) : 179 - 189
  • [35] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [36] CONTRAST ON T2-WEIGHTED IMAGES OF THE LUMBAR SPINE USING FAST SPIN-ECHO AND GATED CONVENTIONAL SPIN-ECHO SEQUENCES
    CHAPPELL, PM
    GLOVER, GH
    ENZMANN, DR
    NEURORADIOLOGY, 1995, 37 (03) : 183 - 186
  • [37] T2-weighted MRI for the assessment of joint effusion: Comparative study of conventional spin-echo and fast spin-echo sequences
    Mori, S
    Kaneda, T
    Lee, K
    Kato, M
    Motohashi, J
    Ogura, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (06): : 768 - 774
  • [38] MR evaluation of rotator cuff pathology using T2-weighted fast spin-echo technique with and without fat suppression
    Singson, RD
    Hoang, T
    Dan, S
    Friedman, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1061 - 1065
  • [39] T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation
    Reeder, Scott B.
    Yu, Huanzhou
    Johnson, Jane W.
    Shimakawa, Ann
    Brittain, Jean H.
    Pelc, Norbert J.
    Beaulieu, Christopher F.
    Gold, Garry E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 825 - 832
  • [40] MRI of acute cerebral infarction: A comparison of FLAIR and T2-weighted fast spin-echo imaging
    Noguchi, K
    Ogawa, T
    Inugami, A
    Fujita, H
    Hatazawa, J
    Shimosegawa, E
    Okudera, T
    Uemura, K
    Seto, H
    NEURORADIOLOGY, 1997, 39 (06) : 406 - 410