Study on water level control system of natural circulation steam generator

被引:10
|
作者
Qiu, Leilei [1 ]
Sun, Aodi [1 ]
Wang, Haomin [1 ]
Zhang, Ru [1 ]
Jiang, Guanfu [1 ]
Sun, Peiwei [1 ]
Wei, Xinyu [1 ]
机构
[1] Xi An Jiao Tong Univ, Shaanxi Engn Res Ctr Adv Nucl Energy, Key Lab Adv Nucl Energy & Technol, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Dynamic characteristics; Nonlinear model; UTSG; Water level control system;
D O I
10.1016/j.pnucene.2022.104436
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The natural circulation U-tube steam generator (UTSG) plays an important role in the operation and safety of pressurized water reactor (PWR) nuclear power plants (NPPs). It is very difficult to control the water level of UTSG during the operation of PWR. Therefore, it is necessary to study its dynamic characteristics. Based on the mass, energy and momentum conservation equations, the nonlinear model (NM) and transfer function model (TM) of UTSG are obtained through mechanism derivation. By introducing typical disturbance into the TM, the changing trend of transient response conforms to the physical law, and the dynamic characteristics are obtained based on the transient results. Based on time domain and frequency domain analysis, the water level control system (WLCS) of UTSG is designed, including the control scheme and controller parameters. The simulation results show that the performance of the WLCS is better than the traditional one. The WLCS not only solves the problem of poor linearity of the feedwater regulating valve (FRV), but also solves the problem of controller redesigning after the FRV replacing. The control system can be switched automatically at 15% power level.
引用
收藏
页数:28
相关论文
共 50 条
  • [11] Performance Assessment for the Water Level Control System in Steam Generator of the Nuclear Power Plant
    Zhang Zhi
    Hu Lisheng
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 5842 - 5847
  • [12] Performance assessment for the water level control system in steam generator of the nuclear power plant
    Zhang, Zhi
    Hu, Li-Sheng
    ANNALS OF NUCLEAR ENERGY, 2012, 45 : 94 - 105
  • [13] Water level control study of steam generator in nuclear power station based on LMIs
    Zhou, Dao-Xi
    Wu, Jie
    Ma, Xiao-Qian
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (11): : 2038 - 2044
  • [14] Design of robust level control system of nuclear steam generator
    Lee, Y. J.
    Na, M. G.
    ICMIT 2007: MECHATRONICS, MEMS, AND SMART MATERIALS, PTS 1 AND 2, 2008, 6794
  • [15] Optimal design of vertical natural circulation steam generator
    Liu, Chengyang
    Yan, Changqi
    Wang, Jianjun
    NUCLEAR ENGINEERING AND DESIGN, 2012, 252 : 167 - 178
  • [16] HIGHLY CHARGED STEAM-GENERATOR WITH NATURAL CIRCULATION
    KRAUS, W
    BRENNSTOFF-WARME-KRAFT, 1972, 24 (12): : 439 - 445
  • [17] Parameter Optimization of Steam Generator Water Level Control System Based on Piecewise ARX Modeling
    Liu, Fang
    Jiang, Yongqiang
    Li, Yuwei
    Peng, Hui
    Wang, Ji
    Peng, Tianbo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (02) : 135 - 153
  • [18] Novel computerized water level control system of PWR steam generator of nuclear power plant
    Khaleeq, M. Tahir
    Lang, Wenpen
    He, Guosen
    Journal of Shanghai University, 1998, 2 (03): : 226 - 236
  • [19] Research on Steam Generator Water Level Control System Based on Nuclear Power Plant Simulator
    Guo, Jianghua
    LIFE SYSTEM MODELING AND INTELLIGENT COMPUTING, PT I, 2010, 97 : 1 - 7
  • [20] Steam generator water level control based on active disturbances rejection control
    Chen, Hong
    Zeng, Jian
    Wang, Guangjun
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (32): : 103 - 107