Feasibility of Implementing Stereotactic Body Radiation Therapy Using a Non-Commercial Volumetric Modulated Arc Therapy Treatment Planning System for Early Stage Lung Cancer

被引:0
|
作者
Song, Yulin [1 ]
Mueller, Boris [1 ]
Obcemea, Ceferino [1 ]
Mychalczak, Borys [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
lung cancer; VMAT; VMAT-SBRT; IMRT-SBRT; RapidArc; SBRT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nearly 25% of patients diagnosed with early-stage non-small cell lung carcinomas (NSCLC) are medically inoperable. For these patients, the radial stereotactic body radiation therapy (SBRT), planned and delivered with intensity modulated radiation therapy (IMRT) techniques, offers the only curative option. However, IMRT-SBRT has three significant deficiencies: an elevated beam-on time (MU); a reduced MU-to-cGy coefficient; and a prolonged delivery time. To address these issues, we have developed our in-house version of volumetric modulated arc therapy (VMAT). In this preliminary study, we compared VMAT-SBRT with IMRT-SBRT in terms of optimization, dosimetry, and delivery. Our goal was to investigate the feasibility of replacing the exiting IMRT-SBRT with VMAT-SBRT as a safe and viable alternative radiation modality for early-stage NSCLC.
引用
收藏
页码:409 / 412
页数:4
相关论文
共 50 条
  • [31] Minimizing dose variation from the interplay effect in stereotactic radiation therapy using volumetric modulated arc therapy for lung cancer
    Kubo, Kazuki
    Monzen, Hajime
    Tamura, Mikoto
    Hirata, Makoto
    Ishii, Kentaro
    Okada, Wataru
    Nakahara, Ryuta
    Kishimoto, Shun
    Kawamorita, Ryu
    Nishimura, Yasumasa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 121 - 127
  • [32] Stereotactic body radiation therapy planning with duodenal sparing using Volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis
    Kumar, Rachit
    Wild, Aaron T.
    Ziegler, Mark A.
    Hooker, Ted K.
    Dah, Samson D.
    Tran, Phuoc T.
    Kang, Jun
    Smith, Koren
    Zeng, Jing
    Pawlik, Timothy M.
    Tryggestad, Erik
    Ford, Eric
    Herman, Joseph M.
    MEDICAL DOSIMETRY, 2013, 38 (03) : 243 - 250
  • [33] Feasibility of MR-only radiation planning for hypofractionated stereotactic radiotherapy of schwannomas using non-coplanar volumetric modulated arc therapy
    Ilamurugu, Arivarasan
    Chandrasekaran, Anu Radha
    Ayyalusamy, Anantharaman
    Shanmugam, Subramanian
    Velayudham, Ramasubramanian
    KattaCharu, Gautham Reddy
    Satpathy, Shyama Prasanna
    RADIOLOGIA MEDICA, 2019, 124 (05): : 400 - 407
  • [34] Feasibility of MR-only radiation planning for hypofractionated stereotactic radiotherapy of schwannomas using non-coplanar volumetric modulated arc therapy
    Arivarasan Ilamurugu
    Anu Radha Chandrasekaran
    Anantharaman Ayyalusamy
    Subramanian Shanmugam
    Ramasubramanian Velayudham
    Gautham Reddy KattaCharu
    Shyama Prasanna Satpathy
    La radiologia medica, 2019, 124 : 400 - 407
  • [35] Treatment Planning and Delivery Evaluation of Volumetric Modulated Arc Therapy for Stereotactic Body Radiotherapy of Spinal Tumours: Impact of Arc Discretization in Planning System
    Marchand, E. L.
    Sahgal, A.
    Zhang, T. J.
    Millar, B. A.
    Sharpe, M.
    Moseley, D.
    Letourneau, D.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2012, 11 (06) : 599 - 606
  • [36] Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients
    Wang, Po-Ming
    Hsu, Wei-Chung
    Chung, Na-Na
    Chang, Feng-Ling
    Jang, Chin-Jyh
    Fogliata, Antonella
    Scorsetti, Marta
    Cozzi, Luca
    RADIATION ONCOLOGY, 2014, 9
  • [37] Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients
    Po-Ming Wang
    Wei-Chung Hsu
    Na-Na Chung
    Feng-Ling Chang
    Chin-Jyh Jang
    Antonella Fogliata
    Marta Scorsetti
    Luca Cozzi
    Radiation Oncology, 9
  • [38] A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer
    Dickey, Mike
    Roa, Wilson
    Drodge, Suzanne
    Ghosh, Sunita
    Murray, Brad
    Scrimger, Rufus
    Gabos, Zsolt
    MEDICAL DOSIMETRY, 2015, 40 (04) : 347 - 351
  • [39] Feasibility Study of Stereotactic Liver Radiation Therapy Using Multiple Divided Partial Arcs in Volumetric Modulated Arc Therapy
    Lin, Y.
    Ozawa, S.
    Tsegmed, U.
    Nakashima, T.
    Shintaro, T.
    Ochi, Y.
    Kawahara, D.
    Kimura, T.
    Nagata, Y.
    MEDICAL PHYSICS, 2014, 41 (06) : 265 - 265
  • [40] A hybrid planning strategy for stereotactic body radiation therapy of early stage non-small-cell lung cancer
    Liu, Han
    Sintay, Benjamin
    Pearman, Keith
    Shang, Qingyang
    Hayes, Lane
    Maurer, Jacqueline
    Vanderstraeten, Caroline
    Wiant, David
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 117 - 123