PURPOSE: To report an unusual complication of accommodative intraocular lens (IOL) implantation after clear lens extraction for hyperopia correction. DESIGN: Observational case report. METHOD: A 48-year,old woman underwent clear lens exchange for the correction of moderate hyperopia. A Crystalens Model AT,45 Accommodating Posterior Chamber IOL (AT-45 IOL) was implanted to allow optimal distance and near vision. At the 3,week follow,up appointment, she complained of monocular diplopia. Ocular examination showed an increased astigmatism, causing decreased visual acuity. Scheimpflug Pentacam Image and Wave Front Analysis supported the diagnosis of IOL tilting. RESULTS: IOL repositioning was unsuccessful because of fibrosis of the haptics. It was necessary to replace AT 45 IOL with a monofocal acrylic sulcus,fixated IOL. CONCLUSION: Control of capsular fibrosis should be a major concern, especially in this type of IOL. Accommodating IOL exchange appears to be a safe alternative to manage this complication.
引用
收藏
页码:341 / 344
页数:4
相关论文
共 50 条
  • [21] Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens
    Schneider, H
    Stachs, O
    Göbel, K
    Guthoff, R
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (03) : 322 - 329
  • [22] Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens
    Hanka Schneider
    Oliver Stachs
    Katja Göbel
    Rudolf Guthoff
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 322 - 329
  • [23] An accommodative intraocular lens study and experiment, based on compliant mechanisms
    Qiuyue Du
    Yuan Li
    Bin Tian
    Microsystem Technologies, 2019, 25 : 4219 - 4225
  • [25] An accommodative intraocular lens study and experiment, based on compliant mechanisms
    Du, Qiuyue
    Li, Yuan
    Tian, Bin
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2019, 25 (11): : 4219 - 4225
  • [26] Functional assessment of two different accommodative Intraocular lenses compared with a monofocal intraocular lens
    Marchini, Giorgio
    Mora, Paolo
    Pedrotti, Emilio
    Manzotti, Francesca
    Aldigeri, Raffaella
    Gandolfi, Stefano A.
    OPHTHALMOLOGY, 2007, 114 (11) : 2038 - 2043
  • [27] Fellow eye comparison between the ICU accommodative intraocular lens and the Acrysof MA30 monofocal intraocular lens
    Heatley, CJ
    Spalton, DJ
    Hancox, J
    Kumar, A
    Marshall, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 207 - 213
  • [28] Test of an accommodative intraocular lens in an ex vivo simulated accommodation model
    Shen, J
    O'Day, DM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U706 - U707
  • [29] Two years experience with the new accommodative 1 CU intraocular lens
    Küchle, M
    Nguyen, NX
    Langenbucher, A
    Gusek-Schneider, GC
    Seitz, B
    OPHTHALMOLOGE, 2002, 99 (11): : 820 - 824
  • [30] A Case of Acute Angle Closure Caused by Dislocation of Accommodative Intraocular Lens
    Hwang, Hyun Ji
    Hwang, Young Hoon
    Lee, Jung Jin
    Kim, Byoung Yeop
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (09): : 1493 - 1497