Atmospheric Pressure Drift Tube Ion Mobility-Orbitrap Mass Spectrometry: Initial Performance Characterization

被引:34
|
作者
Keelor, Joel D. [1 ]
Zambrzycki, Stephen [1 ]
Li, Anyin [1 ]
Clowers, Brian H. [2 ]
Fernandez, Facundo M. [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
[2] Washington State Univ, Dept Chem, Pullman, WA 99164 USA
基金
美国国家科学基金会;
关键词
RESOLVING POWER; SEPARATION; PEPTIDE; MIXTURES; PROTEIN;
D O I
10.1021/acs.analchem.7b01866
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atmospheric pressure drift tube ion mobility spectrometry (AP-DTIMS) was coupled with Fourier transform Orbitrap mass spectrometry. The performance capabilities of this versatile new arrangement were demonstrated for different DTIMS ion gating operation modes and Orbitrap mass spectrometer parameters with regard to sensitivity and resolving power. Showcasing the optimized AP-DTIMS-Orbitrap MS system, isobaric peptide and sugar isomers were successfully resolved and the identities of separated species validated by high-energy collision dissociation experiments.
引用
收藏
页码:11301 / 11309
页数:9
相关论文
共 50 条
  • [1] Fourier transform ion mobility-orbitrap for native mass spectrometry
    McCabe, Jacob
    Poltash, Michael
    Shirzadeh, Mehdi
    Russell, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [2] Fourier transform ion mobility-Orbitrap spectrometer for native mass spectrometry
    McCabe, Jacob
    Shirzadeh, Mehdi
    Russell, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [3] Atmospheric Pressure Drift Tube Ion Mobility Spectrometry Coupled with Two-Dimensional Tandem Mass Spectrometry
    Schrader, Robert L.
    Marsh, Brett M.
    Cooks, R. Graham
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (08) : 2105 - 2109
  • [4] An economical setup for atmospheric pressure chemical ionization drift tube ion-mobility mass spectrometry
    Raju, Chamarthi Maheswar
    Buchowiecki, Krzysztof
    Urban, Pawel L.
    ANALYTICA CHIMICA ACTA, 2023, 1268
  • [5] Flowing atmospheric-pressure afterglow drift tube ion mobility spectrometry
    Latif, Mohsen
    Zhang, Dong
    Gamez, Gerardo
    ANALYTICA CHIMICA ACTA, 2021, 1163
  • [6] Separations of Carbohydrates with Noncovalent Shift Reagents by Frequency-Modulated Ion Mobility-Orbitrap Mass Spectrometry
    McKenna, Kristin R.
    Clowers, Brian H.
    Krishnamurthy, Ramanarayanan
    Liotta, Charles L.
    Fernandez, Facundo M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (09) : 2472 - 2480
  • [7] Digitally-Multiplexed Nanoelectrospray Ionization Atmospheric Pressure Drift Tube Ion Mobility Spectrometry
    Kwasnik, Mark
    Caramore, Joe
    Fernandez, Facundo M.
    ANALYTICAL CHEMISTRY, 2009, 81 (04) : 1587 - 1594
  • [8] Fourier Transform-Ion Mobility-Orbitrap Mass Spectrometer: A Next-Generation Instrument for Native Mass Spectrometry
    Poltash, Michael L.
    McCabe, Jacob W.
    Shirzadeh, Mehdi
    Laganowsky, Arthur
    Clowers, Brian H.
    Russell, David H.
    ANALYTICAL CHEMISTRY, 2018, 90 (17) : 10472 - 10478
  • [9] Comparison of CCS Values Determined by Traveling Wave Ion Mobility Mass Spectrometry and Drift Tube Ion Mobility Mass Spectrometry
    Hinnenkamp, Vanessa
    Klein, Julia
    Meckelmann, Sven W.
    Balsaa, Peter
    Schmidt, Torsten C.
    Schmitz, Oliver J.
    ANALYTICAL CHEMISTRY, 2018, 90 (20) : 12042 - 12050
  • [10] A gated atmospheric pressure drift tube ion mobility spectrometer-time-of-flight mass spectrometer
    Heptner, Andre
    Reinecke, Tobias
    Langejuergen, Jens
    Zimmermann, Stefan
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1356 : 241 - 248