High-Throughput Liquid-Liquid Extractions with Nanoliter Volumes

被引:23
|
作者
Wells, Shane S. [1 ]
Kennedy, Robert T. [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
WATER PARTITION-COEFFICIENTS; CHROMATOGRAPHY-MASS SPECTROMETRY; SOLID-PHASE EXTRACTION; RAPID-DETERMINATION; METAL-IONS; N-OCTANOL; MICROEXTRACTION; FLOW; SOLVENT; CAPILLARY;
D O I
10.1021/acs.analchem.9b04915
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Current methods for liquid-liquid extractions generally require microliter to milliliter volumes of solvents and sample, long equilibration times, and manual procedures. Extraction methods for samples in microfluidic systems have been limited as this tool is difficult to implement on the nanoliter or smaller scale. We have developed slug-flow nanoextraction (SFNE), a method based on droplet microfluidics that allows multiple liquid-liquid extractions to be performed simultaneously in a capillary tube, using only 5 nL of sample and extraction solvent per extraction. Each two-phase slug is segmented from the others by immiscible carrier fluid. We found rapid extractions (<5 s), partition coefficients matching those achieved at larger scale extractions, and potential to preconcentrate samples through volume manipulation. This method was used to accurately and rapidly determine octanol-water partition coefficients (K-ow), determining identical K-ow as the shake-flask method for acetaminophen, K-ow = 2.48 +/- 0.02. The measurement, along with calibration and 12 replicates, was complete within 5 min, consuming under 150 nL of solvent and sample. The method was also applied to extract analytes from complex biological samples prior to electrospray ionization-tandem mass spectrometry (ESI-MS/MS) at a rate of 6 s per sample, allowing for simultaneous determination of five different drugs spiked into human plasma, synthetic urine (SU), and artificial cerebral spinal fluid (aCSF) using ethyl acetate as the extraction phase. The signal-to-noise (S/N) for analytes improved up to 19-fold compared to direct ESI-MS of single-phase droplets (aqueous plugs segmented by carrier fluid), with limits of detection down to 7 nM (35 amol).
引用
收藏
页码:3189 / 3197
页数:9
相关论文
共 50 条
  • [1] Nanoliter Scale Parallel Liquid-Liquid Extraction for High-Throughput Purification on a Droplet Microarray
    Wiedmann, Janne J.
    Demirdoegen, Yelda N.
    Schmidt, Stefan
    Kuzina, Mariia A.
    Wu, Yanchen
    Wang, Fei
    Nestler, Britta
    Hopf, Carsten
    Levkin, Pavel A.
    SMALL, 2023, 19 (09)
  • [2] Intensification of liquid-liquid mass transfer by oscillation in a high-throughput microextractor
    Xie, Tingliang
    Liu, Xuegang
    Xu, Cong
    Chen, Jing
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2017, 120 : 9 - 19
  • [3] HYDRODYNAMICS OF LIQUID-LIQUID EXTRACTIONS
    BAUMAN, E
    OLUJIC, Z
    SINKOVIC, L
    CHEMISCHE TECHNIK, 1978, 30 (10): : 523 - 523
  • [4] Automated high-throughput liquid-liquid extraction for initial purification of combinatorial libraries
    Peng, SX
    Henson, C
    Strojnowski, MJ
    Golebiowski, A
    Klopfenstein, SR
    ANALYTICAL CHEMISTRY, 2000, 72 (02) : 261 - 266
  • [5] From eyes to cameras: Computer vision for high-throughput liquid-liquid separation
    El-khawaldeh, Rama
    Mandal, Abhijoy
    Yoshikawa, Naruki
    Zhang, Wenyu
    Corkery, Ryan
    Prieto, Paloma
    Aspuru-Guzik, Alan
    Darvish, Kourosh
    Hein, Jason E.
    DEVICE, 2024, 2 (07):
  • [6] A high-throughput method for exploring the parameter space of protein liquid-liquid phase separation
    Li, Yichen
    Gu, Jinge
    Liu, Cong
    Li, Dan
    CELL REPORTS PHYSICAL SCIENCE, 2022, 3 (03):
  • [7] Openly Accessible Microfluidic Liquid Handlers for Automated High-Throughput Nanoliter Cell Culture
    Zhou, Ying
    Pang, Yuhong
    Huang, Yanyi
    ANALYTICAL CHEMISTRY, 2012, 84 (05) : 2576 - 2584
  • [8] High-Throughput Liquid-Liquid Fractionation of Multiple Protein Post-Translational Modifications
    DeFord, James H.
    Nuss, Jonathan E.
    Amaning, James
    English, Robert D.
    Tjernlund, Don
    Papaconstantinou, John
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (02) : 907 - 916
  • [9] Tips for Troubleshooting Liquid-Liquid Extractions
    不详
    LC GC NORTH AMERICA, 2017, 35 (12) : 886 - 886
  • [10] High-Throughput Liquid-Liquid Extraction in 96-Well Format: Parallel Artificial Liquid Membrane Extraction
    Gjelstad, Astrid
    Andresen, Alf Terje
    Dahlgren, Anders
    Gundersen, Thomas E.
    Pedersen-Bjergaard, Stig
    LC GC NORTH AMERICA, 2017, 35 (03) : 192 - 196