Characterization of the bone-metal implant interface by Digital Volume Correlation of in-situ loading using neutron tomography

被引:36
|
作者
Le Cann, Sophie [1 ]
Tudisco, Erika [2 ]
Perdikouri, Christina [1 ]
Belfrage, Ola [3 ]
Kaestner, Anders [4 ]
Hall, Stephen [5 ]
Tagil, Magnus [3 ]
Isaksson, Hanna [1 ,3 ]
机构
[1] Lund Univ, Dept Biomed Engn, S-22100 Lund, Sweden
[2] Lund Univ, Div Geotech Engn, Lund, Sweden
[3] Lund Univ, Dept Orthopaed, Lund, Sweden
[4] Paul Sheerer Inst, Swiss Spallat Source, Villigen, Switzerland
[5] Lund Univ, Div Solid Mech, Lund, Sweden
关键词
Neutron tomography; Bone; Metallic screw; Digital Volume Correlation; COMPUTED-TOMOGRAPHY; IMAGE CORRELATION; DENTAL IMPLANTS; TRABECULAR BONE; POROUS-MEDIA; MU-CT; COMBINATION; ZOLEDRONATE; BEAMLINE; MODEL;
D O I
10.1016/j.jmbbm.2017.07.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Metallic implants are commonly used as surgical treatments for many orthopedic conditions. The long-term stability of implants relies on an adequate integration with the surrounding bone. Unsuccessful integration could lead to implant loosening. By combining mechanical loading with high-resolution 3D imaging methods, followed by image analysis such as Digital Volume Correlation (DVC), we aim at evaluating ex vivo the mechanical resistance of newly formed bone at the interface. X-rays tomography is commonly used to image bone but induces artefacts close to metallic components. Utilizing a different interaction with matter, neutron tomography is a promising alternative but has not yet been used in studies of bone mechanics. This work demonstrates that neutron tomography during in situ loading is a feasible tool to characterize the mechanical response of bone implant interfaces, especially when combined with DVC. Experiments were performed where metal screws were implanted in rat tibiae during 4 weeks. The screws were pulled-out while the samples were sequentially imaged in situ with neutron tomography. The images were analyzed to quantify bone ingrowth around the implants. DVC was used to track the internal displacements and calculate the strain fields in the bone during loading. The neutron images were free of metal-related artefacts, which enabled accurate quantification of bone ingrowth on the screw (ranging from 60% to 71%). DVC allowed successful identification of the deformation and cracks that occurred during mechanical loading and led to final failure of the bone-implant interface.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 45 条
  • [21] Characterizing damage evolution in fiber reinforced composites using in-situ X-ray computed tomography, deep machine learning and digital volume correlation (DVC)
    Wang, Yuansong
    Chen, Qingling
    Luo, Quantian
    Li, Qing
    Sun, Guangyong
    COMPOSITES SCIENCE AND TECHNOLOGY, 2024, 254
  • [22] In situ tensile damage characterization of C/C composites through X-ray computed tomography and digital volume correlation
    Li, Wudi
    Jian, Yingjie
    Zhou, Xingui
    Wang, Honglei
    CERAMICS INTERNATIONAL, 2023, 49 (07) : 10471 - 10480
  • [23] Internal damage evolution investigation of C/SiC composites using in-situ tensile X-ray computed tomography testing and digital volume correlation at 1000?C
    Niu, Guohao
    Zhu, Rongqi
    Lei, Hongshuai
    Zhang, Rubing
    Wang, Panding
    Qu, Zhaoliang
    Fang, Daining
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2022, 163
  • [24] Internal damage evolution investigation of C/SiC composites using in-situ tensile X-ray computed tomography testing and digital volume correlation at 1000 °C
    Niu, Guohao
    Zhu, Rongqi
    Lei, Hongshuai
    Zhang, Rubing
    Wang, Panding
    Qu, Zhaoliang
    Fang, Daining
    Composites Part A: Applied Science and Manufacturing, 2022, 163
  • [25] In vivo characterization of the deformation of the human optic nerve head using optical coherence tomography and digital volume correlation
    Midgett, Dan E.
    Quigley, Harry A.
    Nguyen, Thao D.
    ACTA BIOMATERIALIA, 2019, 96 : 385 - 399
  • [26] Measurement of multi-scale deformation of polycarbonate using X-ray scattering with in-situ loading and digital image correlation
    Engqvist, Jonas
    Wallin, Mathias
    Hall, Stephen A.
    Ristinmaa, Matti
    Plivelic, Tomas S.
    POLYMER, 2016, 82 : 190 - 197
  • [27] Fibre-direction strain measurement in a composite ply under quasi-static tensile loading using Digital Volume Correlation and in situ Synchrotron Radiation Computed Tomography
    Schoberl, E.
    Breite, C.
    Melnikov, A.
    Swolfs, Y.
    Mavrogordato, M. N.
    Sinclair, I
    Spearing, S. M.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2020, 137
  • [28] Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation
    Fernandez, Marta Pena
    Kao, Alexander P.
    Bonithon, Roxane
    Howells, David
    Bodey, Andrew J.
    Wanelik, Kazimir
    Witte, Frank
    Johnston, Richard
    Arora, Hari
    Tozzi, Gianluca
    ACTA BIOMATERIALIA, 2021, 131 : 424 - 439
  • [29] Influence of the Casting Process in High Temperature Fatigue of A319 Aluminium Alloy Investigated By In-Situ X-Ray Tomography and Digital Volume Correlation
    Dahdah, Nora
    Limodin, Nathalie
    El Bartali, Ahmed
    Witz, Jean-Francois
    Seghir, Rian
    Charkaluk, Eric
    Buffiere, Jean-Yves
    21ST EUROPEAN CONFERENCE ON FRACTURE, (ECF21), 2016, 2 : 3057 - 3064
  • [30] Mechanical response and strain localization in coal under uniaxial loading, using digital volume correlation on X-ray tomography images
    Vishal, Vikram
    Chandra, Debanjan
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2022, 154