Controlled Release Dinoprostone Insert and Foley Compared to Foley Alone: A Randomized Pilot Trial

被引:3
|
作者
Edwards, Rodney K. [1 ]
Norris, Michelle L. [1 ]
West, Mitchell D. [2 ]
Zornes, Christina [1 ]
Loeffler, Katherine A. [3 ]
Peck, Jennifer D. [3 ]
机构
[1] Univ Oklahoma, Coll Med, Dept Obstet & Gynecol, Oklahoma City, OK 73190 USA
[2] Louisiana State Univ, Hlth Sci Ctr, Dept Obstet & Gynecol, Shreveport, LA 71105 USA
[3] Univ Oklahoma, Hlth Sci Ctr, Sch Publ Hlth, Oklahoma City, OK USA
关键词
cervical ripening; cumulative incidence function; labor; labor induction; LABOR INDUCTION; VAGINAL MISOPROSTOL; COMPETING RISKS; CATHETER; PREINDUCTION; OXYTOCIN; BULB;
D O I
10.1055/s-0040-1705113
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective The aim of study is to compare, in a pilot study, combined dinoprostone vaginal insert and Foley catheter (DVI+Foley) with Foley alone (Foley) for cervical ripening and labor induction at term. Study Design In this open-label pilot randomized controlled trial, women not in labor, with intact membranes, no prior uterine incision, an unfavorable cervix, gestational age >= 37 weeks, and a live, nonanomalous singleton fetus in cephalic presentation were randomly assigned, stratified by parity, to DVI+Foley or Foley. Oxytocin was used in both groups after cervical ripening. Primary outcome was time to vaginal delivery. Results From April 2017 to January 2018, 100 women were randomized. Median (25-75th percentile) time to vaginal delivery for nulliparous women was 21.2 (16.6-38.0) hours with DVI+Foley ( n =26) compared with 31.3 (23.3-46.9) hours with Foley ( n =24) (Wilcoxon p =0.05). Median time to vaginal delivery for parous women was 17.1 (13.6-21.9) hours with DVI+Foley ( n =25) compared with 14.8 (12.7-19.5) hours with Foley ( n =25) (Wilcoxon p =0.21). Results were also analyzed to consider the competing risk of cesarean using cumulative incidence functions. Conclusion Compared with Foley alone, combined use of the dinoprostone vaginal insert and Foley for cervical ripening may shorten time to vaginal delivery for nulliparous but not parous women.
引用
收藏
页码:E57 / E63
页数:7
相关论文
共 50 条
  • [41] Outpatient Foley Catheter for Induction of Labor in Parous Women: A Randomized Controlled Trial Reply
    Kuper, Spencer G.
    Jauk, Victoria C.
    Edwards, Rodney K.
    Harper, Lorie M.
    OBSTETRICS AND GYNECOLOGY, 2018, 132 (04): : 1063 - 1063
  • [42] Six compared with 12 hours of Foley balloon placement for labor induction in nulliparous women with unripe cervices: a randomized controlled trial
    Appadurai, Umadevi
    Gan, Farah
    Hong, Jesrine
    Hamdan, Mukhri
    Tan, Peng Chiong
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2023, 5 (11)
  • [43] Efficacy of Foley Catheter Bulb with Intracervical Dinoprostone Gel versus Dinoprostone Gel Alone for Cervical Ripening and Induction of Labour: An Observational Study
    Bhowmick, Sohan
    Das, Nilratan
    Das, Tanmoy
    Biswas, Arunava
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (05) : QC1 - QC4
  • [44] A randomized trial that compared intravaginal misoprostol and dinoprostone vaginal insert in pregnancies at high risk of fetal distress
    Rozenberg, P
    Chevret, S
    Sénat, MV
    Bretelle, F
    Bonnat, AP
    Ville, Y
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (01) : 247 - 253
  • [45] Oral and vaginal misoprostol compared with dinoprostone for induction of labor: A randomized controlled trial
    le Roux, PA
    Olarogun, JO
    Penny, J
    Anthony, J
    OBSTETRICS AND GYNECOLOGY, 2002, 99 (02): : 201 - 205
  • [46] RETRACTED: Oral misoprostol alone versus oral misoprostol and Foley's catheter for induction of labor: A randomized controlled trial (Retracted Article)
    Husain, Samia
    Husain, Sonia
    Izhar, Rubina
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2017, 43 (08) : 1270 - 1277
  • [47] Labor induction with prostaglandin E1 misoprostol compared with dinoprostone vaginal insert:: A randomized trial
    Sanchez-Ramos, L
    Peterson, DE
    Delke, I
    Gaudier, FL
    Kaunitz, AM
    OBSTETRICS AND GYNECOLOGY, 1998, 91 (03): : 401 - 405
  • [48] A randomized trial of Foley bulb induction of labor trial in nulliparas (FIAT)
    Connolly, Katherine A.
    Kohari, Katherine S.
    Rekawek, Patricia
    Smilen, Broooke
    Miller, Meredith R.
    Moshier, Erin
    Stone, Joanne L.
    Bianco, Angela T.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (01) : S30 - S31
  • [49] Randomized trial of concurrent oxytocin with a sustained-release dinoprostone vaginal insert for labor induction at term
    Christensen, FC
    Tehranifar, M
    Gonzalez, JL
    Qualls, CR
    Rappaport, VJ
    Rayburn, WF
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2002, 186 (01) : 61 - 65
  • [50] Inpatient versus outpatient transcervical Foley catheter use for cervical ripening: a randomized controlled trial
    Pierce-Williams, Rebecca
    Lesser, Henry
    Cohen, Isabelle
    Bauer, Monica
    Berghella, Vincenzo
    D'Adamo, Chris
    Ehsanipoor, Robert
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2022, 226 (01) : S772 - S773