Accuracy Evaluation of Carotid-Femoral Pulse Wave Velocity Estimated by Smart Terminal Watch

被引:1
|
作者
Sun, Ningling [1 ]
Wang, Luyan [1 ]
Xi, Yang [1 ]
Wang, Hongyi [1 ]
Yang, Fan [1 ]
Chen, Yuanyuan [1 ]
Liu, Jing [1 ]
Cui, Yuxian [1 ]
Zeng, Zhechun [2 ]
机构
[1] Peking Univ, Dept Hypertens, Peoples Hosp, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Anzhen Hosp, Beijing Inst Heart Lung & Blood Vessel Dis, Beijing, Peoples R China
来源
关键词
cervical-femoral pulse wave velocity; arterial stiffness; smartwatch; accuracy; Complior arteriosclerosis analyzer; ARTERIAL STIFFNESS; PREDICTION;
D O I
10.3389/fcvm.2022.893557
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the accuracy of the smartwatch in estimating carotid-femoral pulse wave velocity (cfPWV). A cohort of gender-matched volunteers aged 18-80 years were recruited. At the sitting and supine positions, cfPWV was measured alternately by smartwatch and CompliorAnalyse, for each participant, and nine sets of data were collected from each participant with a 60 s interval between measurements. The accuracy of cfPWV measurement for smartwatches was assessed using mean error (ME) and mean absolute error (MAE), while the consistency of the two methods was assessed using the Bland-Altman analysis and concordance class correlation. A total of 347 participants were enrolled. The mean cfPWV was 9.01 +/- 2.29 m/s measured by CompliorAnalyse and 9.06 +/- 1.94 m/s by smartwatch. The consistency correlation coefficient (CCC) was 0.9045 (95% CI 0.8853-0.9206), the ME was 0.046 +/- 0.92, and the MAE was 0.66 (95% CI 0.59-0.73). Bland-Altman analysis showed that the error of 95% samples was in the range between -1.77 m/s and 1.86 m/s. The Kappa value of cfPWV greater than 10 m/s was 0.79, the area under the ROC curve was 0.97 (P < 0.001), sensitivity was 0.90, specificity was 0.93, positive predictive value was 0.83 and negative predictive value was 0.96. Smartwatch can accurately estimate cfPWV to evaluate arterial stiffness. This method is simple and feasible and is suitable for people to actively and early monitor vascular elasticity.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Artificial Intelligence Estimation of Carotid-Femoral Pulse Wave Velocity using Carotid Waveform
    Peyman Tavallali
    Marianne Razavi
    Niema M. Pahlevan
    Scientific Reports, 8
  • [32] Estimation of carotid-femoral pulse wave velocity from finger photoplethysmography signal
    Gentilin, Alessandro
    Tarperi, Cantor
    Cevese, Antonio
    Mattioli, Anna Vittoria
    Schena, Federico
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [33] Carotid-femoral pulse wave velocity is a marker of severity in septic shock patients
    Laviolle, B.
    Uhel, F.
    Seguin, P.
    Bellissant, E.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2014, 28 : 33 - 33
  • [34] The Carotid-Femoral (Aortic) Pulse Wave Velocity and Paraoxonase 1 Activity: Review
    Yildiz, Mustafa
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2012, 32 (02): : 494 - 498
  • [35] Association of homocysteine with carotid-femoral pulse wave velocity in a southern Chinese population
    Wang, Tingjun
    Xu, Guoyan
    Cai, Xiaoqi
    Gong, Jin
    Xie, Qunfang
    Xie, Liangdi
    AGING-US, 2019, 11 (21): : 9709 - 9718
  • [36] Hyperleptinemia is an Independent Predictor for Carotid-Femoral Pulse Wave Velocity in Elderly People
    Yeh, Ying-Ting
    Li, Pei-Chen
    Wang, Ji-Hung
    Lee, Chung-Jen
    Wang, Chih-Hsien
    Hsu, Bang-Gee
    INTERNATIONAL JOURNAL OF GERONTOLOGY, 2020, 14 (01) : 6 - 10
  • [37] Carotid-Femoral Pulse Wave Velocity Is Associated With Nighttime Ambulatory Blood Pressure
    Carlini, Nicholas A.
    Stump, Olivia E.
    Lumadue, Elizabeth J.
    Harber, Matthew P.
    Fleenor, Bradley S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 80 - 80
  • [38] CAROTID-FEMORAL PULSE WAVE VELOCITY VARIABILITY: BEAT-TO-BEAT ASSESSMENT
    Obeid, Hasan
    Tairi, Amira
    Fortier, Catherine
    Giudici, Alessandro
    Spronck, Bart
    Agharazii, Mohsen
    JOURNAL OF HYPERTENSION, 2023, 41 : E268 - E268
  • [39] CAROTID-FEMORAL PULSE WAVE VELOCITY IS THE BEST BIOMECHANICAL MARKER FOR RISK PREDICTION
    Mitchell, Gary F.
    JOURNAL OF HYPERTENSION, 2016, 34 : E32 - E32
  • [40] CAROTID-FEMORAL PULSE WAVE VELOCITY ASSESSED BY ULTRASOUND: A STUDY WITH ECHOTRACKING TECHNOLOGY
    Collette, Mathieu
    Palombo, Carlo
    Morizzo, Carmela
    Sbragi, Sara
    Kozakova, Michaela
    Leftheriotis, Georges
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (06): : 1187 - 1194