Highly accelerated EPI with wave encoding and multi-shot simultaneous multislice imaging

被引:4
|
作者
Cho, Jaejin [1 ,2 ]
Liao, Congyu [3 ,4 ]
Tian, Qiyuan [1 ,2 ]
Zhang, Zijing [5 ]
Xu, Jinmin [5 ]
Lo, Wei-Ching [6 ]
Poser, Benedikt A. [7 ]
Stenger, V. Andrew [8 ]
Stockmann, Jason [1 ,2 ,9 ]
Setsompop, Kawin [3 ,4 ]
Bilgic, Berkin [1 ,2 ,9 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Stanford Univ, Radiol Sci Lab, Dept Radiol, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[5] Zhejiang Univ, State Key Lab Modern Opt Instrumentat, Coll Opt Sci & Engn, Hangzhou, Peoples R China
[6] Siemens Med Solut, Boston, MA USA
[7] Maastricht Univ, Fac Psychol & Neurosci, Maastricht Brain Imaging Ctr, Maastricht, Netherlands
[8] Univ Hawaii, John A Burns Sch Med, Dept Med, MR Res Program, Honolulu, HI 96822 USA
[9] MIT, Harvard MIT Hlth Sci & Technol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
基金
美国国家卫生研究院;
关键词
diffusion imaging; functional imaging; g-Slider; low-rank reconstruction; multi-shot EPI; parallel imaging; SMS imaging; wave-CAIPI; wave-EPI; K-SPACE NEIGHBORHOODS; GHOST CORRECTION; PARALLEL; RECONSTRUCTION; SENSE; CAIPI; MRI; LORAKS; IMAGES;
D O I
10.1002/mrm.29291
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To introduce wave-encoded acquisition and reconstruction techniques for highly accelerated EPI with reduced g-factor penalty and image artifacts. Theory and Methods Wave-EPI involves application of sinusoidal gradients during the EPI readout, which spreads the aliasing in all spatial directions, thereby taking better advantage of 3D coil sensitivity profiles. The amount of voxel spreading that can be achieved by the wave gradients during the short EPI readout period is constrained by the slew rate of the gradient coils and peripheral nerve stimulation monitor. We propose to use a "half-cycle" sinusoidal gradient to increase the amount of voxel spreading that can be achieved while respecting the slew and stimulation constraints. Extending wave-EPI to multi-shot acquisition minimizes geometric distortion and voxel blurring at high in-plane resolutions, while structured low-rank regularization mitigates shot-to-shot phase variations. To address gradient imperfections, we propose to use different point spread functions for the k-space lines with positive and negative polarities, which are calibrated with a FLEET-based reference scan. Results Wave-EPI enabled whole-brain single-shot gradient-echo (GE) and multi-shot spin-echo (SE) EPI acquisitions at high acceleration factors at 3T and was combined with g-Slider encoding to boost the SNR level in 1 mm isotropic diffusion imaging. Relative to blipped-CAIPI, wave-EPI reduced average and maximum g-factors by up to 1.21- and 1.37-fold at R-in x R-sms = 3 x 3, respectively. Conclusion Wave-EPI allows highly accelerated single- and multi-shot EPI with reduced g-factor and artifacts and may facilitate clinical and neuroscientific applications of EPI by improving the spatial and temporal resolution in functional and diffusion imaging.
引用
收藏
页码:1180 / 1197
页数:18
相关论文
共 50 条
  • [41] Comparison of simultaneous multi-slice readout-segmented EPI and conventional single-shot EPI for diffusion tensor imaging of the ulnar nerve
    Ho, Michael
    Becker, Anton
    Ulbrich, Erika
    Manoliu, Andrei
    Kuhn, Felix P.
    Eberhard, Matthias
    Filli, Lukas
    HELIYON, 2018, 4 (10):
  • [42] Spatiotemporal blue noise coded aperture design for multi-shot compressive spectral imaging
    Correa, Claudia V.
    Arguello, Henry
    Arce, Gonzalo R.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2016, 33 (12) : 2312 - 2322
  • [43] An artificial intelligence-accelerated 2-minute multi-shot echo planar imaging protocol for comprehensive high-quality clinical brain imaging
    Clifford, Bryan
    Conklin, John
    Huang, Susie Y.
    Feiweier, Thorsten
    Hosseini, Zahra
    Goncalves Filho, Augusto Lio M.
    Tabari, Azadeh
    Demir, Serdest
    Lo, Wei-Ching
    Longo, Maria Gabriela Figueiro
    Lev, Michael
    Schaefer, Pam
    Rapalino, Otto
    Setsompop, Kawin
    Bilgic, Berkin
    Cauley, Stephen
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2453 - 2463
  • [44] BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI
    Bhavsar, Saurabh
    Zvyagintsev, Mikhail
    Mathiak, Klaus
    NEUROIMAGE, 2014, 84 : 65 - 75
  • [45] Non-contrast renal MRA using multi-shot gradient echo EPI at 3-T MRI
    Morita, Kosuke
    Nakaura, Takeshi
    Yoneyama, Masami
    Nagayama, Yasunori
    Kidoh, Masafumi
    Uetani, Hiroyuki
    Ikeda, Osamu
    Yamashita, Yasuyuki
    Hirai, Toshinori
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 5959 - 5966
  • [46] Improved MUSSELS reconstruction for high-resolution multi-shot diffusion weighted imaging
    Mani, Merry
    Aggarwal, Hemant Kumar
    Magnotta, Vincent
    Jacob, Mathews
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 2253 - 2263
  • [47] Non-contrast renal MRA using multi-shot gradient echo EPI at 3-T MRI
    Kosuke Morita
    Takeshi Nakaura
    Masami Yoneyama
    Yasunori Nagayama
    Masafumi Kidoh
    Hiroyuki Uetani
    Osamu Ikeda
    Yasuyuki Yamashita
    Toshinori Hirai
    European Radiology, 2021, 31 : 5959 - 5966
  • [48] Joint Multi-Shot Multi-Channel Image Reconstruction in Compressive Diffusion Weighted MR Imaging
    Zhang, Hao
    Chen, Yunmei
    Pasiliao, Eduardo, Jr.
    Huang, Feng
    MEDICAL IMAGING 2015: IMAGE PROCESSING, 2015, 9413
  • [49] Model-based reconstruction for simultaneous multislice and parallel imaging accelerated multishot diffusion tensor imaging
    Dong, Zijing
    Dai, Erpeng
    Wang, Fuyixue
    Zhang, Zhe
    Ma, Xiaodong
    Yuan, Chun
    Guo, Hua
    MEDICAL PHYSICS, 2018, 45 (07) : 3196 - 3204
  • [50] MR imaging of the liver using an ultrafast 3D multi-shot EPI sequence - Comparison with four other T1-weighted sequences
    Papanikolaou, N