Design and Performance of the GEMROC ASIC for 2-D Readout of Gas Electron Multiplier Detectors

被引:0
|
作者
Fiutowski, Tomasz [1 ]
Dabrowski, Wladyslaw [1 ]
Mindur, Bartosz [1 ]
Wiacek, Piotr [1 ]
Zielinska, Alicja [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, PL-30059 Krakow, Poland
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we report on the development of an Application Specific Integrated Circuit (ASIC) being a key component for two-dimensional readout of Gas Electron Multiplier (GEM) detectors in the Proton Range Radiography (PRR) system. The GEMROC ASIC consists of 32 independent channels, allowing for simultaneous recording of the amplitudes and time of incoming signals. Thanks to the implemented token-based read out of derandomizing buffers, the ASIC also provides data sparsification and full zero suppression. Reconstruction of the hit positions is performed in an external FPGA based data acquisition system by matching the time stamps of signals recorded in X- and Y-strips. The amplitude information is used for finding centers of gravity for clusters of signals on neighboring strips belonging to the same detection events. Such a readout architecture provides capability of working with high count rates up to 10(6)/s. The circuit has been designed in 0.35 mu m CMOS process. The basic functionality and parameters have been evaluated using the testability functions implemented in the ASIC design. A fully equipped GEM detector module has been built and tested with X-rays and electrons from radioactive sources.
引用
收藏
页码:1540 / 1544
页数:5
相关论文
共 50 条
  • [21] Study of the two dimensional imaging performance for the gas electron multiplier using the resistive anode readout method
    Ju Xu-Dong
    Dong Ming-Yi
    Zhou Chuan-Xing
    Dong Jing
    Zhao Yu-Bin
    Zhang Hong-Yu
    Qi Hui-Rong
    Qun, Ouyang
    ACTA PHYSICA SINICA, 2017, 66 (07)
  • [22] Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and Their Performance
    Gola, Mohit
    XXII DAE HIGH ENERGY PHYSICS SYMPOSIUM, 2018, 203 : 591 - 594
  • [23] First performance evaluation of MexSiC - a readout ASIC for analog SiPM based Cherenkov detectors
    Rosales-Nunez, Sergio A.
    Bautista-Castillo, Alejandro
    Durini, Daniel
    Gonzalez-Diaz, Victor R.
    Diaz-Sanchez, Alejandro
    Rocha-Perez, Jose M.
    Rangel-Magdaleno, Jose de J.
    Alfaro, Ruben
    Iriarte, Arturo
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [24] An aging study of a gas electron multiplier with micro-strip gas chamber readout
    Miyamoto, J
    Shipsey, IPI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 312 - 316
  • [25] Aging study of a gas electron multiplier with micro-strip gas chamber readout
    Purdue Univ, W. Lafayette, United States
    IEEE Trans Nucl Sci, 3 I (312-316):
  • [26] A Simulator for Ballistic Nanostructures in a 2-D Electron Gas
    Huo, Dennis
    Yu, Qiaoyan
    Wolpert, David
    Ampadu, Paul
    ACM JOURNAL ON EMERGING TECHNOLOGIES IN COMPUTING SYSTEMS, 2009, 5 (01)
  • [27] Design and performances of a low-noise and radiation-hardened readout ASIC for CdZnTe detectors
    甘波
    魏廷存
    高武
    胡永才
    Journal of Semiconductors, 2016, (06) : 181 - 187
  • [28] Track resolution measurements for a time projection chamber with gas electron multiplier readout
    Karlen, D
    Poffenberger, P
    Rosenbaum, G
    Carnegie, R
    Dixit, M
    Mes, H
    Sachs, K
    Martin, JP
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 535 - 539
  • [29] Design and performances of a low-noise and radiation-hardened readout ASIC for CdZnTe detectors
    甘波
    魏廷存
    高武
    胡永才
    Journal of Semiconductors, 2016, 37 (06) : 181 - 187
  • [30] Design and performances of a low-noise and radiation-hardened readout ASIC for CdZnTe detectors
    Gan Bo
    Wei Tingcun
    Gao Wu
    Hu Yongcai
    JOURNAL OF SEMICONDUCTORS, 2016, 37 (06)