Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131CS source model CS-1

被引:0
|
作者
Yazdani, M. [1 ]
Mowlavi, A. A. [1 ]
机构
[1] Tarbiat Moallem Univ Sabzevar, Dept Phys, Sabzevar, Iran
来源
关键词
(131)CS source; dose distribution; isodose curves; MCNP code;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background. Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for (131)CS source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the (131)CS Model CS-1 located in the center of 30 cm x30 cm x30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage depth dose (PDD) variation along the different axis, parallel and perpendicular, the source was calculated. Then, the isodose curves for 100%, 75%, 50% and 25% PDD were constructed. Finally, F(r,theta) and g(r) dosimetry parameters of TG-43 protocol have been determined. Results: Results obtained show that the Monte Carlo method could only calculate dose deposition in high gradient region, near the. source, accurately. The energy cut off was found to be 1 eV and the error in the calculations was less than 2%. Conclusion: The isodose curves of the CS-1 (131)CS source were constructed from dose calculation by MCNP code. The calculated dosimetry parameters for the source were in agreement with previously published results.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [31] Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources
    Melhus, Christopher S.
    Rivard, Mark J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1729 - 1737
  • [32] DOSE DISTRIBUTION AROUND A CS-137 SOURCE FOR INTRACAVITARY BRACHYTHERAPY
    URIE, MM
    ANDERSON, LL
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 562 - 563
  • [33] Design of a web page with dosimetric TG-43 parameters for all different models of Cs-137 and Ir-192 sources used in brachytherapy
    Ballester, F
    Perez-Calatayud, J
    Lis, M
    Casal, E
    Granero, D
    Cases, R
    Venselaar, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1877 - 1878
  • [34] TG-43U1 BASED DOSIMETRIC CHARACTERIZATION OF MODEL 67-6520 CS-137 BRACHYTHERAPY SOURCE
    Ballester, F.
    Meigooni, A.
    Wright, C.
    Koona, R. A.
    Awan, S. B.
    Granero, D.
    Perez-Calatayud, J.
    Otal-Palacin, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S222 - S222
  • [35] TG-43U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source
    Wright, C
    Duncan, R
    Rachabatthula, V
    Koona, R
    Meigooni, A
    Baker, C
    MEDICAL PHYSICS, 2005, 32 (06) : 2099 - 2099
  • [36] Carotid dosimetry after re-irradiation with 131Cs permanent implant brachytherapy in recurrent, resected head and neck cancer
    Walsh, Amanda
    Hubley, Emily
    Doyle, Laura
    Cognetti, David
    Curry, Joseph
    Bar-Ad, Voichita
    Luginbuhl, Adam
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (03) : 221 - 226
  • [37] Comparison of dosimetric and biologic effective dose parameters for prostate and urethra using 131CS and 125I for prostate permanent implant brachytherapy
    Sahgal, Arjun
    Jabbari, Siavash
    Chen, Josephine
    Pickett, Barbie
    Roach, Mack, III
    Weinberg, Vivian
    Hsu, I-Chow
    Pouliot, Jean
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : 247 - 254
  • [38] Technical Note: Monte Carlo calculations of the AAPM TG-43 brachytherapy dosimetry parameters for a new titanium-encapsulated Yb-169 source
    Reynoso, Francisco J.
    Munro, John J., III
    Cho, Sang Hyun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 193 - 199
  • [39] The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator
    Simiele, S.
    Micka, J.
    Culberson, W.
    DeWerd, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 111 - +
  • [40] Study for the radial dose function of 131Cs, 125I and 103Pd brachytherapy seeds sources
    Wang, Jian-Hua
    Qiu, Xiao-Ping
    Liu, Wei
    Xu, Xun-Jiang
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (06): : 1223 - 1226