Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131CS source model CS-1

被引:0
|
作者
Yazdani, M. [1 ]
Mowlavi, A. A. [1 ]
机构
[1] Tarbiat Moallem Univ Sabzevar, Dept Phys, Sabzevar, Iran
来源
关键词
(131)CS source; dose distribution; isodose curves; MCNP code;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background. Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for (131)CS source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the (131)CS Model CS-1 located in the center of 30 cm x30 cm x30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage depth dose (PDD) variation along the different axis, parallel and perpendicular, the source was calculated. Then, the isodose curves for 100%, 75%, 50% and 25% PDD were constructed. Finally, F(r,theta) and g(r) dosimetry parameters of TG-43 protocol have been determined. Results: Results obtained show that the Monte Carlo method could only calculate dose deposition in high gradient region, near the. source, accurately. The energy cut off was found to be 1 eV and the error in the calculations was less than 2%. Conclusion: The isodose curves of the CS-1 (131)CS source were constructed from dose calculation by MCNP code. The calculated dosimetry parameters for the source were in agreement with previously published results.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [1] Brachytherapy dosimetry parameters calculated for a 131Cs source
    Rivard, Mark J.
    MEDICAL PHYSICS, 2007, 34 (02) : 754 - 762
  • [2] AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source
    Zhang, PP
    Beddar, AS
    Sibata, CH
    MEDICAL PHYSICS, 2004, 31 (04) : 755 - 759
  • [3] Brachytherapy dosimetry parameters calculated for a 131Cs source (vol 34, pg 754, 2007)
    Rivard, Mark J.
    MEDICAL PHYSICS, 2009, 36 (01) : 279 - 279
  • [4] Dosimetric characterization of a 131Cs brachytherapy source by thermoluminescence dosimetry in liquid water
    Tailor, Ramesh
    Ibbott, Geoffrey
    Lampe, Stephanie
    Warren, Whitney Bivens
    Tolani, Naresh
    MEDICAL PHYSICS, 2008, 35 (12) : 5861 - 5868
  • [5] Brachytherapy TG-43 dosimetry characterization of the INTRABEAM source
    Alvarez, D. S. Ayala
    Watson, P. G. F.
    Popovic, M.
    Heng, V. J.
    Evans, M. D. C.
    Seuntjens, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S97 - S99
  • [6] Potential impact of prostate edema on the dosimetry of permanent seed implants using the new 131Cs (model CS-1) seeds
    Chen, Z
    Deng, J
    Roberts, K
    Nath, R
    MEDICAL PHYSICS, 2006, 33 (04) : 968 - 975
  • [7] Determination of 137Cs dosimetry parameters according to the AAPM TG-43 formalism
    Liu, LZ
    Prasad, SC
    Bassano, DA
    MEDICAL PHYSICS, 2004, 31 (03) : 477 - 483
  • [8] Investigation of Pagat Gel Dosimeter Application in Lowe Dose Rate Brachytherapy by Detemination of TG-43 Parameters of Selectron Cs-137 Source
    Zehtabian, M.
    Faghihi, R.
    Meigooni, A.
    Mosleh-Shirazi, M.
    Zahmatkesh, M.
    Mehdizadeh, S.
    Sina, S.
    Nili, M.
    Mansouri, K.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source
    Simiele, S.
    Palmer, B.
    DeWerd, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3625 - 3625
  • [10] Monte Carlo calculation of the relative TG-43 dosimetry parameters for the INTRABEAM electronic brachytherapy source
    Alvarez, David Santiago Ayala
    Watson, Peter G. F.
    Popovic, Marija
    Heng, Veng Jean
    Evans, Michael D. C.
    Seuntjens, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):