A New Ultrasonic Flowmeter with Low Power Consumption for Small Pipeline Applications

被引:0
|
作者
Zhao, Weiguo [1 ]
Jiang, Yanfu [1 ]
Huang, Chaochuan [2 ]
机构
[1] China Jiliang Univ, Zhejiang Prov Key Lab Flow Measurement Technol, Hangzhou 310018, Peoples R China
[2] Zhejiang Cangnan Instrument Grp, Cangnan 325800, Peoples R China
关键词
water flowmeter; small pipeline; time difference measurement; invariable delay time threshold filter; low power consumption; FLOW METER; PROFILE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to solve the problem of flow measurement in small pipelines, a new ultrasonic flowmeter has been designed in this paper. The pipe model with built-in reflector and variable diameter is put forward with the purpose of increasing the ultrasonic transmitting path. The low voltage driving circuit is used so as to reduce power consumption. The filter method with temperature compensation is proposed to process the echo signal. The flow measurement error due to acoustic speed is also corrected. The new ultrasonic flowmeter is designed with timing chips TDC-GP22 and the microprocessor MSP430F437, which also reduces power consumption. The experimental results show that the accuracy of the ultrasonic flowmeter is better than 1% and the total power and is lower than 0.21mW.
引用
收藏
页码:1105 / 1110
页数:6
相关论文
共 50 条
  • [21] A miniaturized transit-time ultrasonic flowmeter based on ScAlN piezoelectric micromachined ultrasonic transducers for small-diameter applications
    Yunfei Gao
    Minkan Chen
    Zhipeng Wu
    Lei Yao
    Zhihao Tong
    Songsong Zhang
    Yuandong Alex Gu
    Liang Lou
    Microsystems & Nanoengineering, 9
  • [22] LOW-POWER INTEGRATED-CIRCUITS FOR AN IMPLANTABLE PULSED DOPPLER ULTRASONIC BLOOD FLOWMETER
    GILL, RW
    MEINDL, JD
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1975, 10 (06) : 464 - 471
  • [23] An efficient asynchronous pipeline FIFO for low-power applications
    Gholipour, M
    Afzali-Kusha, A
    Nourani, M
    Khademzadeh, A
    2002 45TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, CONFERENCE PROCEEDINGS, 2002, : 481 - 484
  • [24] Snake: An asynchronous pipeline for ultra-low-power applications
    Zhu, Zhi-jiu
    Xu, Yi
    Bai, Xu
    Qiao, Shu-shan
    Hei, Yong
    IEICE ELECTRONICS EXPRESS, 2019, 16 (12):
  • [25] A New Modulation Scheme for Low Power Consumption and Small Size Passive RFID Tags
    Abdo, Ibrahim
    Odeh, Mutasem
    Shahroury, Fadi R.
    2013 IEEE CONFERENCE ON WIRELESS SENSOR (ICWISE), 2013, : 68 - 72
  • [26] Theoretical and experimental evaluation of small flow rate ultrasonic flowmeter
    Seyed Hossein Roshanaei
    Reza Askari Moghadam
    Bahram Tarvirdizadeh
    Negar Riahi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2022, 44
  • [27] Ultrasonic Transducer Positioning System for Clamp-on Flowmeter Applications
    Bailleu, Anett
    2016 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2016) PROCEEDINGS, 2016, : 122 - 127
  • [28] Theoretical and experimental evaluation of small flow rate ultrasonic flowmeter
    Roshanaei, Seyed Hossein
    Moghadam, Reza Askari
    Tarvirdizadeh, Bahram
    Riahi, Negar
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2022, 44 (08)
  • [29] An ultrasonic transit-time gas flowmeter for automotive applications
    Kupnik, M
    Schröder, A
    O'Leary, P
    Benes, E
    Gröschl, M
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 451 - 454
  • [30] Jumo The new Ultrasonic Flowmeter Series JUMO flowTRANS
    不详
    WASSERWIRTSCHAFT, 2022, 112 (05) : 66 - 66