Energy performance assessment of double-skin facade with thermal mass

被引:81
|
作者
Fallahi, Ali [1 ]
Haghighat, Fariborz [1 ]
Elsadi, Hafia [1 ]
机构
[1] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Energy; Building; Double-skin facade; Thermal mass; Thermal storage; Airflow; Natural ventilation; MEDITERRANEAN CLIMATES; NUMERICAL-ANALYSIS; FREE CONVECTION; VALIDATION; BEHAVIOR; LAMINAR;
D O I
10.1016/j.enbuild.2010.03.020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To mitigate the overheating problem in the warmer seasons, and thereby improve thermal performance and energy efficiency of the double-skin facade (DSF) system, this study introduced an innovative design approach involving the integration of passive thermal mass technique with the air channel of the conventional DSF. To assess the contribution of this integration to energy efficiency of the system, a numerical model was developed, capable of determining the thermal performance of the conventional DSF. The numerical model is composed of airflow and thermal models. This paper briefly describes the development of the models as well as the models' verifications. Models were then used to carry out a series of parametric studies to investigate the effect of thermal mass on the energy performance of the integrated system. The simulation results revealed that mechanically ventilated DSF can save energy based on configuration from 21% to 26% in summer and from 41% to 59% in winter as compared to conventional DSFs without thermal mass. The results also showed the total saving for a naturally ventilated DSF is negligible year-round. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1499 / 1509
页数:11
相关论文
共 50 条
  • [31] Optimal operation of a south double-skin facade
    Gratia, E
    De Herde, A
    ENERGY AND BUILDINGS, 2004, 36 (01) : 41 - 60
  • [32] A qualitative investigation on double-skin facade fires
    Chow, C. L.
    1ST INTERNATIONAL SEMINAR FOR FIRE SAFETY OF FACADES, 2013, 9
  • [33] Structural Performance of Double-Skin Facade Systems Subjected to Blast Pressures
    Tuan Ngo
    Ding, Chao
    Lumantarna, Raymond
    Ghazlan, Abdallah
    Zobec, Marc
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (12)
  • [34] FUNCTIONAL AERODYNAMICS AND ITS INFLUENCE ON THE ENERGY AND THERMAL MODE OF A NATURALLY VENTILATED DOUBLE-SKIN TRANSPARENT FACADE
    Franek, Michal
    Bielek, Boris
    Macak, Marek
    Klem, Josip
    ACTA POLYTECHNICA, 2022, 62 (04) : 459 - 472
  • [35] Thermal Performance of Double Skin Facade Windows
    He, Guoqing
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1964 - 1969
  • [36] Thermal behaviour and efficiency of ventilated double-skin facade in Polish climatic conditions
    Heim, D.
    Janicki, M.
    RESEARCH ON BUILDING PHYSICS, 2010, : 257 - 263
  • [37] Characteristics of NCR building's double-skin facade system and evaluation of its thermal performance by measurements
    Kawashima N.
    Hayasaka S.
    Tsurumi R.
    Asawa T.
    Yasuda K.
    AIJ Journal of Technology and Design, 2019, 25 (60) : 771 - 776
  • [38] Summer performance of a naturally ventilated double-skin facade with adjustable glazed louvers for building energy retrofitting
    Lin, Zhenghao
    Song, Yehao
    Chu, Yingnan
    ENERGY AND BUILDINGS, 2022, 267
  • [39] Photovoltaic double-skin facade: A combination of active and passive utilizations of solar energy
    Xu, Chunwen
    Ma, Xiao
    Yu, Chuck Wah Francis
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (08) : 1013 - 1017
  • [40] Performance evaluation of photovoltaic double-skin facade with forced ventilation in the composite climate
    Preet, Sajan
    Sharma, Manoj Kumar
    Mathur, Jyotirmay
    Chowdhury, Amartya
    Mathur, Sanjay
    JOURNAL OF BUILDING ENGINEERING, 2020, 32