Timing optimization for 3D silicon sensors

被引:0
|
作者
Loi, Angelo [1 ,2 ]
Contu, Andrea [1 ]
Mendicino, Roberto [3 ,4 ]
Forcolin, Giulio Tiziano [3 ,4 ]
Lai, Adriano [5 ]
Dalla Betta, Gian Franco [3 ,4 ]
Boscardin, Maurizio [4 ,5 ]
Vecchi, Stefania [6 ]
机构
[1] INFN, Sez Cagliari, Str Prov Sestu,Km 0-7, I-09042 Monserrato, CA, Italy
[2] Univ Cagliari, Dipartimento Fis, Str Prov Sestu,Km 0-7, I-09042 Monserrato, CA, Italy
[3] Univ Trento, Dipartimento Ingn Ind, Via Sommar 9, I-38123 Trento, Italy
[4] INFN, TIFPA, Via Sommar 14, I-38123 Trento, Italy
[5] FBK, Via Sommar 18, I-38123 Trento, Italy
[6] INFN, Sez Ferrara, Via Saragat 1, I-44122 Ferrara, Italy
关键词
3D silicon sensors; 4D tracking detectors; Timing optimization; Ramo map;
D O I
10.1016/j.nima.2019.162491
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Looking forward to future High Luminosity LHC experiments, efforts to develop new tracking detectors are increasing. A common approach to improve track reconstruction efficiency in high pile-up conditions is to add time measurement per pixel with resolution smaller than 50 ps. Different sensor technologies are under development in order to achieve those performances, like low gain avalanche diodes and 3D sensors. 3D sensors are characterized by very fast charge collection times, but present some critical issues in timing due to their electrode configurations. The presence of zero electric field volumes inside the electrodes themselves and low electric field regions between same sign electrodes causes that the 3D sensor technology presents potentially a large time walk contribution which negatively affects time resolution. In order to reduce this error drastically, a detailed study based mostly on simulation has been done with main focus on the exploration for a timing optimized 3D sensor electrode configuration. To have a more detailed view of the timing performances, sensor operation was also simulated, using TCAD and other simulation tools developed specific for this application, and the results analysed. In this presentation a detailed overview of the modelling and simulation activity as well as their results, including also future steps will be presented. The output of this studies defines the optimal sensor layout for timing applications.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Increased Speed: 3D Silicon Sensors; Fast Current Amplifiers
    Parker, Sherwood
    Kok, Angela
    Kenney, Christopher
    Jarron, Pierre
    Hasi, Jasmine
    Despeisse, Matthieu
    Da Via, Cinzia
    Anelli, Giovanni
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (02) : 404 - 417
  • [22] Recent developments and future perspectives in 3D silicon radiation sensors
    Dalla Betta, G. -F.
    Da Via, C.
    Povoli, M.
    Parker, S.
    Boscardin, M.
    Darbo, G.
    Grinstein, S.
    Grenier, P.
    Hasi, J.
    Kenney, C.
    Kok, A.
    Lai, C. -H.
    Pellegrini, G.
    Watts, S.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [23] TCAD simulation of 3D silicon sensors for thermal neutron imaging
    Ye, Jixing
    Polo, Matteo
    Mendicino, Roberto
    Quaranta, Alberto
    Dalla Betta, Gian-Franco
    JOURNAL OF INSTRUMENTATION, 2025, 20 (02):
  • [24] Ultra-thin 3D silicon sensors for neutron detection
    Guardiola, C.
    Fleta, C.
    Pellegrini, G.
    Garcia, F.
    Quirion, D.
    Rodriguez, J.
    Lozano, M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [25] Timing-Optimised 3D Silicon Sensor with Columnar Electrode Geometry
    Loi, Angelo
    Lai, Adriano
    Ye, Jixing
    Dalla Betta, Gian-Franco
    SENSORS, 2025, 25 (03)
  • [26] Development of 3D trenched-electrode pixel sensors with improved timing performance
    Forcolin, G. T.
    Mendicino, R.
    Boscardin, M.
    Lai, A.
    Loi, A.
    Ronchin, S.
    Vecchi, S.
    Dalla Betta, G-F
    JOURNAL OF INSTRUMENTATION, 2019, 14 (07):
  • [27] Beam test results of 3D silicon pixel sensors for future upgrades
    Nellist, C.
    Gligorova, A.
    Huse, T.
    Pacifico, N.
    Sandaker, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 141 - 145
  • [28] Hybrid Detectors of Neutrons Based on 3D Silicon Sensors with Polysiloxane Converter
    Dalla Betta, Gian-Franco
    Boscardin, Maurizio
    Carturan, Sara
    Cinausero, Marco
    Collazuol, Gianmaria
    Dalla Palma, Matteo
    Giacomini, Gabriele
    Gramegna, Fabiana
    Granja, Carlos
    Marchi, Tommaso
    Mendicino, Roberto
    Perillo, Ennio
    Povoli, Marco
    Quaranta, Alberto
    Ronchin, Sabina
    Slavicek, Tomas
    Stefanik, Milan
    Vacik, Jiri
    Zorzi, Nicola
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [29] Test beam results of 3D silicon pixel sensors for the ATLAS upgrade
    Grenier, P.
    Alimonti, G.
    Barbero, M.
    Bates, R.
    Bolle, E.
    Borri, M.
    Boscardin, M.
    Buttar, C.
    Capua, M.
    Cavalli-Sforza, M.
    Cobal, M.
    Cristofoli, A.
    G.-F. Dalla Betta
    Darbo, G.
    Da Via, C.
    Devetak, E.
    DeWilde, B.
    Di Girolamo, B.
    Dobos, D.
    Einsweiler, K.
    Esseni, D.
    Fazio, S.
    Fleta, C.
    Freestone, J.
    Gallrapp, C.
    Garcia-Sciveres, M.
    Gariano, G.
    Gemme, C.
    Giordani, M. -P.
    Gjersdal, H.
    Grinstein, S.
    Hansen, T.
    Hansen, T. -E.
    Hansson, P.
    Hasi, J.
    Helle, K.
    Hoeferkamp, M.
    Huegging, F.
    Jackson, P.
    Jakobs, K.
    Kalliopuska, J.
    Karagounis, M.
    Kenney, C.
    Koehler, M.
    Kocian, M.
    Kok, A.
    Kolya, S.
    Korokolov, I.
    Kostyukhin, V.
    Krueger, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 638 (01): : 33 - 40
  • [30] Optimization of contrast timing for breath-hold 3D MR angiography
    Hany, TF
    McKinnon, GC
    Leung, DA
    Goehde, SC
    Debatin, JF
    RADIOLOGY, 1997, 205 : 671 - 671