A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model

被引:50
|
作者
Arnold, W [1 ]
Shikora, SA [1 ]
机构
[1] Tufts Univ, New England Med Ctr, Dept Surg, Ctr Minimally Invas Obes Surg, Boston, MA 02111 USA
关键词
staple line; staple line disruption; bovine pericardial strips; staple line buttressing; Peristrips Dry((R)); burst pressure;
D O I
10.1381/0960892053268309
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The consequences of a staple-line leak or disruption can be devastating particularly in the bariatric surgery population. This study was designed to assess if gastrointestinal staple-lines buttressed with bovine pericardium could tolerate greater intraluminal pressures compared with non-reinforced staple-lines. Methods: A laparoscopic linear cutting staple device was used to create divided staple-lines across the small intestine in a porcine model and the stomach in a rabbit model. 21 staple-lines were created with buttressing strips of bovine pericardium, and another 21 staple-lines were created without any reinforcement. All staple-lines were subjected to a constant rate increase in intraluminal pressure via intraluminal infusion of a dye solution. At the first sign of seam leak or failure, the burst pressure was recorded. Results: In 19 of the 21 studies, the staple-lines buttressed with bovine pericardium sustained higher mean burst pressures than the conventional non-buttressed staple-lines. For the porcine intestinal segments, the mean intraluminal pressure at failure was 125 +/- 24 mmHg for buttressed staple-lines versus 58.4 +/- 28mm Hg for conventional staple lines (P <0.0001). For rabbit stomach segments, the mean intraluminal pressure at failure was also significantly higher for the buttressed segments (115 +/- 24 vs 75.6 +/- 23, P <0.0137). Most buttressed segments failed away from the staple-line, while the non-buttressed segments failed at the staple-line. Conclusions: Gastrointestinal staple-lines buttressed with bovine pericardium are able to maintain seam integrity at significantly higher intraluminal pressures when compared to non-buttressed GI staple-lines in animal models.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 12 条
  • [11] Comparison between pressure-recording analytical method (PRAM) and femoral arterial thermodilution method (FATD) cardiac output monitoring in an infant animal model of cardiac arrest
    Urbano J.
    López J.
    González R.
    Fernández S.N.
    Solana M.J.
    Toledo B.
    Carrillo Á.
    López-Herce J.
    Intensive Care Medicine Experimental, 4 (1)
  • [12] Biomechanical comparison between cortical screw-rod construct versus pedicle screw-rod construct in transforaminal lumbar interbody fusion: A porcine animal study model
    Wei, Chris Chan Yin
    Haw, Sem Sei
    Bashir, Elrofai Suliman
    Beng, Saw Lim
    Shanmugam, Rukmanikanthan
    Keong, Kwan Mun
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01):