Quantification of stiffness measurement errors in resonant ultrasound spectroscopy of human cortical bone

被引:17
|
作者
Cai, Xiran [1 ]
Peralta, Laura [1 ]
Gouttenoire, Pierre-Jean [2 ]
Olivier, Cecile [2 ,3 ]
Peyrin, Francoise [2 ,3 ]
Laugier, Pascal [1 ]
Grimal, Quentin [1 ]
机构
[1] Univ Paris 06, Lab Imagerie Biomed, Sorbonne Univ, INSERM,CNRS,UMR S 1146,UMR 7371,UPMC, 15 Rue Ecole Med, F-75006 Paris, France
[2] ESRF, 71 Ave Martyrs, F-38043 Grenoble, France
[3] Univ Claude Bernard Lyon 1, Univ Lyon, INSA Lyon, CNRS,INSERM,CREATIS,UMR 5220,U1206, 7 Ave Jean Capelle, F-69621 Villeurbanne, France
来源
关键词
ELASTIC-MODULI; MECHANICAL-PROPERTIES; COEFFICIENTS; PROPAGATION; CONSTANTS; SYSTEM; SAMPLE;
D O I
10.1121/1.5009453
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Resonant ultrasound spectroscopy (RUS) is the state-of-the-art method used to investigate the elastic properties of anisotropic solids. Recently, RUS was applied to measure human cortical bone, an anisotropic material with low Q-factor (20), which is challenging due to the difficulty in retrieving resonant frequencies. Determining the precision of the estimated stiffness constants is not straightforward because RUS is an indirect method involving minimizing the distance between measured and calculated resonant frequencies using a model. This work was motivated by the need to quantify the errors on stiffness constants due to different error sources in RUS, including uncertainties on the resonant frequencies and specimen dimensions and imperfect rectangular parallelepiped (RP) specimen geometry. The errors were first investigated using Monte Carlo simulations with typical uncertainty values of experimentally measured resonant frequencies and dimensions assuming a perfect RP geometry. Second, the exact specimen geometry of a set of bone specimens were recorded by synchrotron radiation micro-computed tomography. Then, a "virtual" RUS experiment is proposed to quantify the errors induced by imperfect geometry. Results show that for a bone specimen of similar to 1 degrees perpendicularity and parallelism errors, an accuracy of a few percent (<6.2%) for all the stiffness constants and engineering moduli is achievable. (C) 2017 Acoustical Society of America.
引用
收藏
页码:2755 / 2765
页数:11
相关论文
共 50 条
  • [21] Anisotropic elastic properties of human cortical bone tissue inferred from inverse homogenization and resonant ultrasound spectroscopy (vol 11, 100730, 2020)
    Cai, Xiran
    Peralta, Laura
    Brenner, Renald
    Iori, Gianluca
    Cassereau, Didier
    Raum, Kay
    Laugier, Pascal
    Grimal, Quentin
    MATERIALIA, 2021, 15
  • [22] Cortical bone elasticity measured by resonant ultrasound spectroscopy is not altered by defatting and synchrotron X-ray imaging
    Cai, X.
    Peralta, L.
    Giron, A.
    Helfen, L.
    Olivier, C.
    Peyrin, F.
    Laugier, P.
    Grimal, Q.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 72 : 241 - 245
  • [24] INVIVO MEASUREMENT OF THE ULTRASOUND ATTENUATION COEFFICIENT IN CORTICAL BONE
    HYODYNMAA, SJ
    KARELLAS, A
    WHITING, JS
    CRAVEN, JD
    GREENFIELD, MA
    MEDICAL PHYSICS, 1981, 8 (04) : 555 - 555
  • [25] In vivo and in vitro measurement of ultrasound velocity in cortical bone
    Lowet, G
    VanderPerre, G
    BONE RESEARCH IN BIOMECHANICS, 1997, 40 : 201 - 220
  • [26] Assessment of trabecular bone tissue elasticity with resonant ultrasound spectroscopy
    Daoui, H.
    Cai, X.
    Boubenider, F.
    Laugier, P.
    Grimal, Q.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 74 : 106 - 110
  • [27] Resonant ultrasound spectroscopy measurement of the elastic constants of cyclotrimethylene trinitramine
    Schwarz, RB
    Hooks, DE
    Dick, JJ
    Archuleta, JI
    Martinez, AR
    JOURNAL OF APPLIED PHYSICS, 2005, 98 (05)
  • [28] Measurement of Mechanical Properties of Enamel Based on Resonant Ultrasound Spectroscopy
    Niu, Haijun
    Fan, Fan
    Wang, Rui
    Zhang, Qiang
    Ren, Pengling
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 583 - 586
  • [29] THE MEASUREMENT OF ELASTIC CONSTANTS OF QUARTZ CRYSTAL BY RESONANT ULTRASOUND SPECTROSCOPY
    Wang, Zhen
    Wang, Ji
    Xu, Xiang-wu
    Du, Jian-ke
    Ma, Ting-feng
    PROCEEDINGS OF THE 2012 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA12), 2012, : 341 - 344
  • [30] Resonant ultrasound spectroscopy for measurement of mechanical damping: Comparison with broadband viscoelastic spectroscopy
    Lee, T
    Lakes, RS
    Lal, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (07): : 2855 - 2861