Variable selection for quantitative determination of glucose concentration with near-infrared spectroscopy

被引:4
|
作者
McShane, MJ
Cote, GL
Spiegelman, C
机构
关键词
near-infrared spectroscopy; glucose; multivariate calibration; variable selection;
D O I
10.1117/12.273614
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near-infrared spectroscopy has been used in combination with multivariate calibration techniques such as partial-least squares regression (PLSR) to quantify glucose concentration in various media. However, for reasonable prediction capability in measuring glucose many calibration samples are needed. In addition, spectroscopic data often contain over 1000 data points, presenting a very large data matrix for calibration. It is desirable to reduce the available data to contain only the information necessary for accurate prediction of chemical concentration before PLSR is applied. This will eliminate noisy variables and consequently the data can be processed more quickly and efficiently. A variable selection method that reduces prediction bias in single factor partial least squares regression models was developed and applied to near-infrared absorbance spectra of glucose in two different media: pH buffer and cell culture medium. Comparisons between calibration and prediction capability for full spectra and reduced sets were completed, resulting in statistically equivalent mean squared errors. The number of response variables needed to fit the calibration data and accurately predict concentrations from new spectra was reduced in each case. The algorithm correctly chose the glucose peak areas as the informative variables and computation time was decreased by an order of magnitude.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [21] Effect of variable selection and rapid determination of total tea polyphenols contents in Fuzhuan tea by near-infrared spectroscopy
    Liu, Jing-Xue
    Xin, Jia-Ying
    Gao, Ting-Ting
    Li, Feng-Lin
    Tian, Xie
    CYTA-JOURNAL OF FOOD, 2022, 20 (01) : 236 - 243
  • [22] Photoacoustic determination of glucose concentration in whole blood by a near-infrared laser diode
    Zhao, ZM
    Myllylä, R
    BIOMEDICAL OPTOACOUSTICS II, 2001, 4256 : 77 - 83
  • [23] Quantitative near-infrared spectroscopy of Of and WNL stars
    Bohannan, B
    Crowther, PA
    ASTROPHYSICAL JOURNAL, 1999, 511 (01): : 374 - 388
  • [24] Quantitative determination of oxides in cement raw meal based on near-infrared spectroscopy and hybrid feature selection strategy
    Ma, Xiaoyu
    Wang, Xiaohong
    Huang, Bing
    Cai, Yongqi
    Zhang, Rongfeng
    INFRARED PHYSICS & TECHNOLOGY, 2024, 141
  • [25] Variables selection methods in near-infrared spectroscopy
    Zou Xiaobo
    Zhao Jiewen
    Povey, Malcolm J. W.
    Holmes, Mel
    Mao Hanpin
    ANALYTICA CHIMICA ACTA, 2010, 667 (1-2) : 14 - 32
  • [26] Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy
    Amerov, AK
    Chen, J
    Small, GW
    Arnold, MA
    ANALYTICAL CHEMISTRY, 2005, 77 (14) : 4587 - 4594
  • [27] Near-infrared spectroscopy for determination of glucose lactate, and ammonia in cell culture media
    McShane, MJ
    Cote, GL
    APPLIED SPECTROSCOPY, 1998, 52 (08) : 1073 - 1078
  • [28] Comparison of several variable selection methods for quantitative analysis and monitoring of the Yangxinshi tablet process using near-infrared spectroscopy
    Chen, Yong
    Ma, Hui
    Zhang, Qing
    Zhang, Siyu
    Chen, Ming
    Wu, Yongjiang
    INFRARED PHYSICS & TECHNOLOGY, 2020, 105 (105)
  • [29] Rapid determination of hyaluronic acid concentration in fermentation broth with near-infrared spectroscopy
    Dong, Qin
    Zang, Hengchang
    Zang, Lixuan
    Liu, Aihua
    Shi, Yanli
    Zhang, Hui
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2014, 7 (06)
  • [30] Quantitative determination of the human breast milk macronutrients by near-infrared Raman spectroscopy
    Motta, Edlene do Carmo M.
    Zangaro, Renato A.
    Silveira, Landulfo, Jr.
    OPTICAL DIAGNOSTICS AND SENSING XII: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE IV, 2012, 8229