NUMERICAL ANALYSIS OF HEAT TRANSFER IN A FLAT-PLATE SOLAR COLLECTOR WITH NANOFLUIDS

被引:10
|
作者
Yurddas, Ali [1 ]
Cerci, Yunus [2 ]
机构
[1] Celal Bayar Univ, Dept Mech Engn, TR-45140 Muradiye, Manisa, Turkey
[2] Adnan Menderes Univ, Dept Mech Engn, TR-09010 Aytepe, Aydin, Turkey
关键词
flat-plate solar collector; nanofluid; finite volume method; mixed convection; LAMINAR MIXED CONVECTION; TRANSFER ENHANCEMENT; THERMAL-CONDUCTIVITY; NATURAL-CONVECTION; FORCED-CONVECTION; HORIZONTAL TUBE; INCLINED TUBES; FLOW; EFFICIENCY; ENCLOSURE;
D O I
10.1615/HeatTransRes.2016012266
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer aspects of a typical flat-plate solar collector utilizing water-based nanofluids as the working fluid were analyzed numerically. Water-based nanofluids of various compositions containing metallic Al2O3 and Cu nanoparticles with volume fractions ranging from 1% to 5% were examined, and the effects of the nanofluids on the heat transfer were quantified. Relevant parameters such as the heat flux, Reynolds number, and the collector tilt angle were calculated and compared to each other at different boundary conditions. The flat-plate solar collector geometry was simplified, and only a fluid carrying pipe with an absorber surface was chosen as a numerical model with a particular attention to symmetry, instead of taking the entire collector geometry. The numerical model was controlled and confirmed by applying it to similar studies existing in the pertinent literature. All numerical solutions were carried out by using a commercial finite volume soft ware package called ANSYS Fluent. The results show that the nanofluids increase the heat transfer rate ranging from 1% to 8%, when compared to water as a working fluid.
引用
收藏
页码:681 / 714
页数:34
相关论文
共 50 条
  • [41] Experimental and numerical study of the freezing process of flat-plate solar collector
    Zhou, Fan
    Ji, Jie
    Cai, Jingyong
    Yu, Bendong
    APPLIED THERMAL ENGINEERING, 2017, 118 : 773 - 784
  • [42] Flow and heat transfer analysis of TiO2/water nanofluid in a ribbed flat-plate solar collector
    Bazdidi-Tehrani, Farzad
    Khabazipur, Arash
    Vasefi, Seyed Iman
    RENEWABLE ENERGY, 2018, 122 : 406 - 418
  • [43] HEAT REMOVAL FACTOR FOR A FLAT-PLATE SOLAR COLLECTOR WITH A SERPENTINE TUBE
    ABDELKHALIK, SI
    SOLAR ENERGY, 1976, 18 (01) : 59 - 64
  • [44] 2-DIMENSIONAL ANALYSIS OF A FLAT-PLATE SOLAR COLLECTOR
    RAO, PP
    FRANCIS, JE
    LOVE, TJ
    JOURNAL OF ENERGY, 1977, 1 (05): : 324 - 328
  • [45] PERFORMANCE OF AN INVERTED FLAT-PLATE SOLAR COLLECTOR
    TIWARI, GN
    GARG, HP
    HUSAIN, MS
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1984, 8 (03) : 223 - 229
  • [46] A solar still augmented with a flat-plate collector
    Badran, AA
    Al-Hallaq, AA
    Salman, IAE
    Odat, MZ
    DESALINATION, 2005, 172 (03) : 227 - 234
  • [47] TRANSIENT CHARACTERISTICS OF FLAT-PLATE SOLAR COLLECTOR
    SAITO, A
    UTAKA, Y
    TSUCHIO, T
    KATAYAMA, K
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1983, 26 (211): : 79 - 86
  • [48] PERFORMANCE OF TUBELESS FLAT-PLATE SOLAR COLLECTOR
    TAMIMI, A
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1987, 11 (01) : 153 - 155
  • [49] Thermodynamic optimization of solar flat-plate collector
    Saha, SK
    Mahanta, DK
    RENEWABLE ENERGY, 2001, 23 (02) : 181 - 193
  • [50] FLAT-PLATE SOLAR COLLECTOR DESIGN AND SIZING
    HOWELL, JR
    JOURNAL OF ENERGY, 1979, 3 (06): : 379 - 382