High-resolution room-temperature sample scanning superconducting quantum interference device microscope configurable for geological and biomagnetic applications

被引:56
|
作者
Fong, LE
Holzer, JR
McBride, KK
Lima, EA
Baudenbacher, F
Radparvar, M
机构
[1] Vanderbilt Univ, Nashville, TN 37235 USA
[2] Hypres Inc, Elmsford, NY 10523 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2005年 / 76卷 / 05期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
D O I
10.1063/1.1884025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with submillimeter resolution. The low-critical-temperature (T-c(c)) niobium-based monolithic SQUID sensors are mounted on the tip of a sapphire and thermally anchored to the helium reservoir. A 25 mm sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows us to adjust the sample-to-sensor spacing from the top of the Dewar. We achieved a sensor-to-sample spacing of 100 mm, which could be maintained for periods of up to four weeks. Different SQUID sensor designs are necessary to achieve the best combination of spatial resolution and field sensitivity for a given source configuration. For imaging thin sections of geological samples, we used a custom-designed monolithic low-T (niobium bare SQUID sensor, with an effective diameter of 80 mm, and achieved a field sensitivity of 1.5 pT/Hz1/2 and a magnetic moment sensitivity of 5.4x10-18 A m2/Hz1/2 at a sensor-to-sample spacing of 100 mm in the white noise region for frequencies above 100 Hz. Imaging action currents in cardiac tissue requires a higher field sensitivity, which can only be achieved by compromising spatial resolution. We developed a monolithic low-T)(c) niobium multiloop SQUID sensor, with sensor sizes ranging from 250 mm to 1 mm, and achieved sensitivities of 480-180 fT/Hz1/2 in the white noise region for frequencies above 100 Hz, respectively. For all sensor configurations, the spatial resolution was comparable to the effective diameter and limited by the sensor-to-sample spacing. Spatial registration allowed us to compare high-resolution images of magnetic fields associated with action currents and optical recordings of transmembrane potentials to study the bidomain nature of cardiac tissue or to match petrography to magnetic field maps in thin sections of geological samples. 2005 American Institute of Physics.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] High-resolution imaging using a high-Tc superconducting quantum interference device (SQUID) magnetometer
    Egli, R
    Heller, F
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2000, 105 (B11) : 25709 - 25727
  • [22] Disposable sample holder for high temperature measurements in MPMS superconducting quantum interference device magnetometers
    Sese, J.
    Bartolome, J.
    Rillo, C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (04):
  • [23] High-resolution scanning magnetometry based on a superconducting quantum interferometer
    Gudoshnikov, SA
    Matveets, LV
    Migulin, VV
    Snigirev, OV
    Tishin, AM
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2001, 46 (07) : 729 - 740
  • [24] High-resolution scanning magnetometry based on a superconducting quantum interferometer
    Gudoshnikov, S.A.
    Matveets, L.V.
    Migulin, V.V.
    Snigirev, O.V.
    Tishin, A.M.
    2001, Nauka Moscow (46):
  • [25] Properties of high Tc superconducting quantum interference device microscope with high μ-metal needle
    Tanaka, S
    Matsuda, K
    Yamazaki, O
    Natsume, M
    Ota, H
    Mizoguchi, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2001, 40 (5A): : L431 - L433
  • [26] Flux trapping in a superconducting thin film as revealed by simulations and scanning superconducting quantum interference device microscope observations
    Tanaka, K
    Morooka, T
    Odawara, A
    Chinone, K
    Mawatari, Y
    Koyanagi, M
    APPLIED PHYSICS LETTERS, 2000, 77 (11) : 1677 - 1679
  • [27] Investigation of a magnetic flux-guide for a HTS scanning superconducting quantum interference device microscope
    Baek, B
    Moon, SH
    Lee, SY
    Lee, SM
    Kye, JI
    Lee, HJ
    Khim, ZG
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2004, 17 (08): : 1022 - 1025
  • [28] Relationship between spatial resolution and noise in scanning superconducting quantum interference device microscopy
    Chatraphorn, S
    Fleet, EF
    Wellstood, FC
    JOURNAL OF APPLIED PHYSICS, 2002, 92 (08) : 4731 - 4740
  • [29] Advancement in scanning magnetic microscopy utilizing high-sensitivity room-temperature TMR sensors for geological applications
    Oda, Hirokuni
    Kumagai, Seiji
    Fujiwara, Kosuke
    Matsuzaki, Hitoshi
    Wagatsuma, Hiroshi
    Oogane, Mikihiko
    Kubota, Hitoshi
    Fukuyo, Naoto
    Tanimoto, Akihiro
    EARTH PLANETS AND SPACE, 2024, 76 (01):
  • [30] HTS scanning SQUID microscope with high spatial resolution for room temperature samples
    Gudoshnikov, SA
    Liubimov, BY
    Deryuzhkina, YV
    Matveets, LV
    Snigirev, OV
    Kalabukhov, AS
    Ranchinski, ML
    Schmidl, F
    Seidel, P
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 372 : 166 - 169