Graphene oxide coated long period grating based fibre optic humidity sensor

被引:2
|
作者
Dissanayake, Kasun P. W. [1 ]
Wu, Weiping [1 ]
Nguyen, Hien [1 ]
Sun, Tong [1 ]
Grattan, Kenneth T. V. [1 ,2 ]
机构
[1] City Univ London, Sch Math Comp Sci & Engn, Northampton Sq, London EC1V 0HB, England
[2] City Univ London, City Grad Sch, Northampton Sq, London EC1V 0HB, England
关键词
humidity sensor; long period grating; graphene oxide; optical fibre;
D O I
10.1117/12.2265465
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the response of a graphene oxide (GO) coated long period grating (LPG) to the change in temperature and in humidity is reported. To create the probe, an improved Hummer's method was used to synthesis the GO solution used as its basis, allowing coating of functionalized LPG by using a multi-layer dip coating technique. A consistent and stable response of the resonance peak intensity of the GO coated LPG was observed to the change in humidity, achieving a sensitivity of 0.15 dB / % RH with a linear correlation coefficient of 0.9804 over the relative humidity range from 60% RH to 95% RH at room temperature (25 degrees C). A blue shift of the resonance peak wavelength was recorded when the proposed sensor was exposed to varying temperature conditions from 25 degrees C to 70 degrees C and the response was found to be linear with a correlation coefficient of 0.9973. The GO coated LPG humidity sensor probe performed with a good stability and repeatability over a number of test cycles in this initial performance evaluation.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Long period grating-based humidity sensor for potential structural health monitoring
    Venugopalan, T.
    Sun, T.
    Grattan, K. T. V.
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 148 (01) : 57 - 62
  • [42] Parametric study of a polymer-coated fibre-optic humidity sensor
    David, Nigel A.
    Wild, Peter M.
    Djilali, Ned
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (03)
  • [43] Bovine Serum Albumin Detection by Graphene Oxide Coated Long-Period Fiber Grating
    Ruiduo Wang
    Hao Wu
    Mei Qi
    Jing Han
    Zhaoyu Ren
    Photonic Sensors, 2022, 12
  • [44] Bovine Serum Albumin Detection by Graphene Oxide Coated Long-Period Fiber Grating
    Wang, Ruiduo
    Wu, Hao
    Qi, Mei
    Han, Jing
    Ren, Zhaoyu
    PHOTONIC SENSORS, 2022, 12 (03)
  • [45] High-performance fibre-optic humidity sensor based on a side-polished fibre wavelength selectively coupled with graphene oxide film
    Huang, Yaoming
    Zhu, Wenguo
    Li, Zhibin
    Chen, Guanglei
    Chen, Liheng
    Zhou, Junjie
    Lin, Hai
    Guan, Junwen
    Fang, Wenxiao
    Liu, Xin
    Dong, Huazhuo
    Tang, Jieyuan
    Guan, Heyuan
    Lu, Huihui
    Xiao, Yi
    Zhang, Jun
    Wang, Hongcheng
    Chen, Zhe
    Yu, Jianhui
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 57 - 69
  • [46] Simultaneous measurement of humidity and temperature based on a partially coated optical fiber long period grating
    Urrutia, Aitor
    Goicoechea, Javier
    Ricchiuti, Amelia L.
    Barrera, David
    Sales, Salvador
    Arregui, Francisco J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 227 : 135 - 141
  • [47] Reduced Graphene Oxide-Based Interferometric Fiber-Optic Humidity Sensor
    Ke Weiming
    Li Zhenhua
    Zhou Zhixiang
    Lin Yanmei
    Xiao Yi
    ACTA OPTICA SINICA, 2019, 39 (12)
  • [48] Characterisation of a polymer-coated fibre Bragg grating sensor for relative humidity sensing
    Yeo, TL
    Sun, T
    Grattan, KTV
    Parry, D
    Lade, R
    Powell, BD
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (01) : 148 - 155
  • [49] An Immunosensor Based on the Graphene-Oxide-Encapsulated Au-Nanoshell-Coated Long-Period Fiber Grating
    Shi Shenghui
    Wu Decao
    Wang Xin
    Nie Qinglin
    Liu Zhijiang
    Luo Binbin
    Liu Enhua
    Liu Peng
    Zhao Mingfu
    ACTA OPTICA SINICA, 2020, 40 (18)
  • [50] Long-period grating relative humidity sensor with hydrogel coating
    Liu, Yang
    Wang, Liwei
    Zhang, Min
    Tu, Dongsheng
    Mao, Xianhui
    Liao, Yanbiao
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2007, 19 (9-12) : 880 - 882