Harmonization of Quantitative Parenchymal Enhancement in T1-Weighted Breast MRI

被引:5
|
作者
van Der Velden, Bas H. M. [1 ]
van Rijssel, Michael J. [1 ]
Lena, Beatrice [1 ]
Philippens, Marielle E. P. [2 ]
Loo, Claudette E. [3 ]
Ragusi, Max A. A. [1 ]
Elias, Sjoerd G. [4 ]
Sutton, Elizabeth J. [5 ]
Morris, Elizabeth A. [5 ]
Bartels, Lambertus W. [1 ]
Gilhuijs, Kenneth G. A. [1 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Image Sci Inst, Utrecht, Netherlands
[2] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[3] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiol, Amsterdam, Netherlands
[4] Univ Utrecht, Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[5] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10021 USA
关键词
CARCINOMA IN-SITU; INTEROBSERVER VARIABILITY; NEOADJUVANT CHEMOTHERAPY; CONTRAST-MEDIA; ASSOCIATION; RECURRENCE; PREDICTS; IMAGES; RISK;
D O I
10.1002/jmri.27244
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Differences in imaging parameters influence computer-extracted parenchymal enhancement measures from breast MRI. Purpose To investigate the effect of differences in dynamic contrast-enhanced MRI acquisition parameter settings on quantitative parenchymal enhancement of the breast, and to evaluate harmonization of contrast-enhancement values with respect to flip angle and repetition time. Study Type Retrospective. Phantom/Populations We modeled parenchymal enhancement using simulations, a phantom, and two cohorts (N = 398 and N = 302) from independent cancer centers. Sequence Field/Strength 1.5T dynamic contrast-enhanced T-1-weighted spoiled gradient echo MRI. Vendors: Philips, Siemens, General Electric Medical Systems. Assessment We assessed harmonization of parenchymal enhancement in simulations and phantom by varying the MR parameters that influence the amount of T-1-weighting: flip angle (8 degrees-25 degrees) and repetition time (4-12 msec). We calculated the median and interquartile range (IQR) of the enhancement values before and after harmonization. In vivo, we assessed overlap of quantitative parenchymal enhancement in the cohorts before and after harmonization using kernel density estimations. Cohort 1 was scanned with flip angle 20 degrees and repetition time 8 msec; cohort 2 with flip angle 10 degrees and repetition time 6 msec. Statistical Tests Paired Wilcoxon signed-rank-test of bootstrapped kernel density estimations. Results Before harmonization, simulated enhancement values had a median (IQR) of 0.46 (0.34-0.49). After harmonization, the IQR was reduced: median (IQR): 0.44 (0.44-0.45). In the phantom, the IQR also decreased, median (IQR): 0.96 (0.59-1.22) before harmonization, 0.96 (0.91-1.02) after harmonization. Harmonization yielded significantly (P < 0.001) better overlap in parenchymal enhancement between the cohorts: median (IQR) was 0.46 (0.37-0.58) for cohort 1 vs. 0.37 (0.30-0.44) for cohort 2 before harmonization (57% overlap); and 0.35 (0.28-0.43) vs. .0.37 (0.30-0.44) after harmonization (85% overlap). Data Conclusion The proposed practical harmonization method enables an accurate comparison between patients scanned with differences in imaging parameters. Level of Evidence 3 Technical Efficacy Stage 4
引用
收藏
页码:1374 / 1382
页数:9
相关论文
共 50 条
  • [31] T1-weighted and T2-weighted MRI image synthesis with convolutional generative adversarial networks
    Kawahara, Daisuke
    Nagata, Yasushi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (01) : 35 - 42
  • [32] Anatomically-Guided Segmentation of Cerebral Microbleeds in T1-Weighted and T2*-Weighted MRI
    Kwon, Junmo
    Seo, Sang Won
    Park, Hyunjin
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT II, 2024, 15002 : 24 - 33
  • [33] Parenchymal enhancement on breast MRI may be a marker for cancer risk: correlation of parenchymal enhancement with breast density.
    Arkani, S.
    Newstead, G.
    Chen, V
    Cranford, C.
    Karczmar, G.
    BREAST CANCER RESEARCH AND TREATMENT, 2006, 100 : S126 - S126
  • [34] Tractography with T1-weighted MRI and associated anatomical constraints on clinical quality diffusion MRI
    Yu, Tian
    Li, Yunhe
    Kim, Michael E.
    Gao, Chenyu
    Yang, Qi
    Cai, Leon Y.
    Resnick, Susane M.
    Beason-Held, Lori L.
    Moyer, Daniel C.
    Schilling, Kurt G.
    Landman, Bennett A.
    MEDICAL IMAGING 2024: IMAGE PROCESSING, 2024, 12926
  • [35] Reply to Letter to the Editor: "Augmented T1-weighted steady state MRI "
    Ye, Yongquan
    Lyu, Jingyuan
    Hu, Yichen
    Zhang, Zhongqi
    Xu, Jian
    Zhang, Weiguo
    Yuan, Jianmin
    Zhou, Chao
    Fan, Wei
    Zhang, Xu
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [36] Liver, meconium, haemorrhage: the value of T1-weighted images in fetal MRI
    Jan Zizka
    Pavel Elias
    Karel Hodik
    Jaroslav Tintera
    Vera Juttnerova
    Zdenek Belobradek
    Ludovit Klzo
    Pediatric Radiology, 2006, 36 : 792 - 801
  • [37] High signal intensities on T1-weighted MRI as a biomarker of exposure to manganese
    Kim, YH
    INDUSTRIAL HEALTH, 2004, 42 (02) : 111 - 115
  • [38] Diagnostic Utility of T1-Weighted MRI Characteristics in Evaluation of Osteomyelitis of the Foot
    Johnson, Paul W.
    Collins, Mark S.
    Wenger, Doris E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (01) : 96 - 100
  • [39] Segmental hyperintensity on T1-weighted MRI of the liver: Indication of segmental cholestasis
    Gabata, T
    Matsui, O
    Kadoya, M
    Yoshikawa, J
    Ueda, K
    Kawamori, Y
    Takashima, T
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05): : 855 - 857
  • [40] Fast, automatic segmentation of the brain in T1-weighted volume MRI data
    Lemieux, L
    Hagemann, G
    Krakow, K
    Woermann, FG
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 152 - 160