Wear resistance of plasma immersion ion implanted Ti6Al4V

被引:77
|
作者
Johns, SM
Bell, T
Samandi, M
Collins, GA
机构
[1] UNIV WOLLONGONG,DEPT MAT ENGN,WOLLONGONG,NSW 2500,AUSTRALIA
[2] AUSTRALIAN NUCL SCI & TECHNOL ORG,SUTHERLAND,NSW 2234,AUSTRALIA
来源
SURFACE & COATINGS TECHNOLOGY | 1996年 / 85卷 / 1-2期
关键词
plasma ion implantation; Ti6Al4V; wear; surface engineering;
D O I
10.1016/0257-8972(96)02884-8
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The plasma immersion ion implantation (PI3 TM) process has been employed in the treatment of the Ti6Al4V alloy in order to improve its notoriously poor tribological properties. In particular, this study was undertaken with a view to its potential application for the surface engineering of orthopaedic implants. PI3 has been developed over recent years at the Australian Nuclear Science and Technology Organisation (ANSTO). The hybrid nature of this technique combines elements of both ion implantation and plasma nitriding, and has been shown to produce components with unique surface properties and optimum performance characteristics. A detailed study of the PI3 process on the Ti6Al4V alloy has been undertaken. Treatment was carried out in a pure nitrogen atmosphere at temperatures of 350, 450 and 550 degrees C. In each case, specimens were treated for 5 h, with a high voltage pulse (typically 40 kV) applied directly to the workpiece. Wear resistance of the treated samples was assessed using a standard CSEM pin-on-disc wear machine, with a single crystal ruby ball as the contact lip. Glancing angle X-ray diffraction (GAXRD) was employed to determine the phases present in the surface modified layer. These findings were then compared to those achieved from parallel work with conventionally ion implanted and low temperature plasma nitrided samples. It was established that a high treatment temperature of 550 degrees C was necessary for substantial improvements in the properties of the Ti6Al4V material. Under these conditions the PI3 technique promoted significant increases in Knoop hardness, and wear resistance an order of magnitude greater than conventional ion implantation. Wear rates were typically reduced by four orders of magnitude compared to those of the untreated Ti6Al4V. This is thought to be associated with the increased mobility of nitrogen in alpha-Ti at these temperatures, producing a deeper, hardened case. The presence of TiN was observed in the microstructure of PI3 Ti6Al4V samples at all temperatures in the range.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 50 条
  • [31] Frictional Wear Resistance and Corrosion Resistance of Ag/Ti-6Al-4V Alloy System Treated by Plasma Immersion Ion Implantation Technique (PIII)
    Liu Hongxi
    Jiang Yehua
    Zhou Rong
    Zhan Zhaolin
    Yang Tianwu
    Tang Baoyin
    RARE METAL MATERIALS AND ENGINEERING, 2009, 38 (12) : 2126 - 2130
  • [32] Influence of annealing on depth distributions and microstructure of ion-implanted Ti6Al4V
    H. Schmidt
    G. Miehe
    A. Schminke
    M. Soltanifarshi
    Metallurgical and Materials Transactions A, 1999, 30 : 2121 - 2127
  • [33] A comparison of the surface characteristics and ion release of Ti6Al4V and heat-treated Ti6Al4V
    Lee, TM
    Chang, E
    Yang, CY
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 50 (04): : 499 - 511
  • [34] Wear and corrosion resistance of Ti6Al4V alloy irradiated by high-intensity pulsed ion beam
    Lei, M. K.
    Dong, Z. H.
    Zhang, Z.
    Hu, Y. F.
    Zhu, X. P.
    SURFACE & COATINGS TECHNOLOGY, 2007, 201 (9-11): : 5613 - 5616
  • [35] Measurement and analysis of tool wear and surface characteristics in micro turning of SLM Ti6Al4V and wrought Ti6Al4V
    Airao, Jay
    Kishore, Hreetabh
    Nirala, Chandrakant K.
    MEASUREMENT, 2023, 206
  • [36] Wear Resistance of Different Bionic Structure Manufactured by Laser Cladding on Ti6Al4V
    Wu, Mengyao
    Zhan, Xiaohong
    Bu, Hengchang
    Liu, Lijun
    Song, Yuanzeng
    Li, Yaping
    METALS AND MATERIALS INTERNATIONAL, 2021, 27 (07) : 2319 - 2327
  • [37] Wear-resistance improvement of Ti6Al4V surface by thermal oxidation treatment
    Yin, Zhen-Xing
    Luo, Bing-Hui
    Zhongnan Gongye Daxue Xuebao/Journal of Central South University of Technology, 2004, 35 (02):
  • [38] Wear Resistance of Different Bionic Structure Manufactured by Laser Cladding on Ti6Al4V
    Mengyao Wu
    Xiaohong Zhan
    Hengchang Bu
    Lijun Liu
    Yuanzeng Song
    Yaping Li
    Metals and Materials International, 2021, 27 : 2319 - 2327
  • [39] Several plasma diffusion processes for improving wear properties of Ti6Al4V alloy
    Yetim, A. F.
    Yildiz, F.
    Vangolu, Y.
    Alsaran, A.
    Celik, A.
    WEAR, 2009, 267 (12) : 2179 - 2185
  • [40] Deformation behavior and wear resistance of hard TiCN and TiCN/Ti coatings on Ti6Al4V alloy
    Sun, Yong
    Lu, Cheng
    Yu, Hailiang
    Tieu, A. Kiet
    Zhu, Qiang
    Zhao, Yue
    Zhu, Hongtao
    Advances in Materials and Processing Technologies XVI, 2014, 939 : 451 - 458