A computerized Langmuir probe system

被引:12
|
作者
Pilling, LS [1 ]
Bydder, EL [1 ]
Carnegie, DA [1 ]
机构
[1] Univ Waikato, Dept Phys & Elect Engn, Hamilton 2001, New Zealand
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2003年 / 74卷 / 07期
关键词
D O I
10.1063/1.1581362
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For low pressure plasmas it is important to record entire single or double Langmuir probe characteristics accurately. For plasmas with a depleted high energy tail, the accuracy of the recorded ion current plays a critical role in determining the electron temperature. Even for high density Maxwellian distributions, it is necessary to accurately model the ion current to obtain the correct electron density. Since the electron and ion current saturation values are, at best, orders of magnitude apart, a single current sensing resistor cannot provide the required resolution to accurately record these values. We present an automated, personal computer based data acquisition system for the determination of fundamental plasma properties in low pressure plasmas. The system is designed for single and double Langmuir probes, whose characteristics can be recorded over a bias voltage range of +/-70 V with 12 bit resolution. The current flowing through the probes can be recorded within the range of 5 nA-100 mA. The use of a transimpedance amplifier for current sensing eliminates the requirement for traditional current sensing resistors and hence the need to correct the raw data. The large current recording range is realized through the use of a real time gain switching system in the negative feedback loop of the transimpedance amplifier. (C) 2003 American Institute of Physics.
引用
收藏
页码:3341 / 3346
页数:6
相关论文
共 50 条
  • [21] CONTROL-SYSTEM FOR MAINTAINING A LANGMUIR PROBE AT PLASMA POTENTIAL
    MICHAU, JL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (09): : 1174 - 1178
  • [22] Optimization of Langmuir Probe System Parameters in a Stationary Laboratory Plasma
    朱颖
    曹金祥
    牛田野
    王亮
    王艳
    王舸
    Plasma Science and Technology, 2006, (06) : 639 - 643
  • [23] MICROCOMPUTER-BASED DATA-ACQUISITION SYSTEM FOR THE LANGMUIR PROBE
    WONG, CS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (04): : 632 - 632
  • [24] The Langmuir probe system in the Wendelstein 7-X test divertor
    Rudischhauser, L.
    Endler, M.
    Hoefel, U.
    Hammond, K. C.
    Kallmeyer, J. P.
    Blackwell, B. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (06):
  • [25] Fast scanning Langmuir probe system for ASDEX-Upgrade divertor
    Tsois, N.
    Dorn, C.
    Kyriakakis, G.
    Markoulaki, M.
    Pflug, M.
    Schramm, G.
    Theodoropoulos, P.
    Xantopoulos, P.
    Weinlich, M.
    Journal of Nuclear Materials, 1999, 266 : 1230 - 1233
  • [26] Spatial survey of a magnetron plasma sputtering system using a Langmuir probe
    Field, DJ
    Dew, SK
    Burrell, RE
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2002, 20 (06): : 2032 - 2041
  • [27] Langmuir Probe Measurements in a Grid-Assisted Magnetron Sputtering System
    Sagas, Julio Cesar
    Pessoa, Rodrigo Savio
    Maciel, Homero Santiago
    BRAZILIAN JOURNAL OF PHYSICS, 2018, 48 (01) : 61 - 66
  • [28] Langmuir Probe Measurements in a Grid-Assisted Magnetron Sputtering System
    Julio César Sagás
    Rodrigo Sávio Pessoa
    Homero Santiago Maciel
    Brazilian Journal of Physics, 2018, 48 : 61 - 66
  • [29] MULTIPLE SWEEP, FLOATING LANGMUIR PROBE SYSTEM FOR PULSED DISCHARGE DIAGNOSTICS
    LACOSTE, J
    DIMOFF, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (09): : 1278 - 1281
  • [30] A fast scanning Langmuir probe system for ASDEX-Upgrade divertor
    Tsois, N
    Dorn, C
    Kyriakakis, G
    Markoulaki, M
    Pflug, M
    Schramm, G
    Theodoropoulos, P
    Xantopoulos, P
    Weinlich, M
    JOURNAL OF NUCLEAR MATERIALS, 1999, 266 : 1230 - 1233