Quantum noise suppression in X-ray images using fuzzy 2-D Wiener filter

被引:6
|
作者
Toprak, Abdullah [1 ]
机构
[1] Dicle Univ, Meslek Yuksek Okulu, Elekt Bolumu, Diyarbakir, Turkey
关键词
fuzzy Wiener filter; quantum noise; noise suppression; X-ray image;
D O I
10.1007/s10916-007-9076-x
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The noisy images are caused by decreasing quantity of the produced X-ray due to the deformation of the X-ray tube's anode. While obtaining the image from low quantity X-ray, shot noise or quantum noise occurs, and this decreases the quality of the image. The aim of this study is to define the novel method called as Fuzzy 2-D Weiner filter (FWF-2D), which suppresses the shot noise from noisy image by avoiding any harm to the image details. With this filtering technique, it is possible to preserve the sharp-edge and the details of the image without any damage during suppressing the noise from images. FWF-2D is one of the best techniques to suppress the corrupted quantum noises due to damaged X-ray tube. The fuzzy rules used in this filter are aimed to distinguish noise pixels from image ones, and the Wiener Filter is working to remove noise pixels distinguished by these fuzzy rules. It is then possible to obtain clean images from damaged X-ray tubes by using FWF-2D technique.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 50 条
  • [21] Quantum Noise Removal in X-Ray Images with Adaptive Total Variation Regularization
    Prasath, V. B. Surya
    INFORMATICA, 2017, 28 (03) : 505 - 515
  • [22] IMAGE STATISTICS AND QUANTUM NOISE IN X-RAY COMPUTED-TOMOGRAPHY IMAGES
    DUERINCKX, AJ
    MACOVSKI, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 773 - 773
  • [23] Java']Java based functional link multilayer perceptron adaptive filter for Poisson noise suppression from X-ray images
    Kumar, M.
    Mishra, S. K.
    MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (18) : 24405 - 24425
  • [24] Ribs Suppression in Chest X-Ray Images by Using ICA Method
    Hieu Xuan Nguyen
    Tin Thanh Dang
    5TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING IN VIETNAM, 2015, 46 : 194 - 197
  • [25] Noise reduction for low-dose X-ray computed tomography with fuzzy filter
    Gui, Zhi-guo
    Liu, Yi
    OPTIK, 2012, 123 (13): : 1207 - 1211
  • [26] Noise regeneration in compressed x-ray images
    Breeuwer, M
    vanOtterloo, PJ
    IMAGE DISPLAY: MEDICAL IMAGING 1996, 1996, 2707 : 261 - 272
  • [27] Fuzzy segmentation of X-ray fluoroscopy images
    Russakoff, DB
    Rohlfing, T
    Maurer, CR
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 146 - 154
  • [28] X-RAY OPTICS BY THE USE OF 2-D BENT CRYSTALS
    FORSTER, E
    USCHMANN, I
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 495 - 498
  • [29] When 2-D X-ray isn't enough
    Moller-Gunderson, David
    SMT Surface Mount Technology Magazine, 2007, 21 (08):
  • [30] Crack detection in X-ray images using fuzzy index measure
    Linda, C. Harriet
    Jiji, G. Wiselin
    APPLIED SOFT COMPUTING, 2011, 11 (04) : 3571 - 3579