Quantum noise suppression in X-ray images using fuzzy 2-D Wiener filter

被引:6
|
作者
Toprak, Abdullah [1 ]
机构
[1] Dicle Univ, Meslek Yuksek Okulu, Elekt Bolumu, Diyarbakir, Turkey
关键词
fuzzy Wiener filter; quantum noise; noise suppression; X-ray image;
D O I
10.1007/s10916-007-9076-x
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The noisy images are caused by decreasing quantity of the produced X-ray due to the deformation of the X-ray tube's anode. While obtaining the image from low quantity X-ray, shot noise or quantum noise occurs, and this decreases the quality of the image. The aim of this study is to define the novel method called as Fuzzy 2-D Weiner filter (FWF-2D), which suppresses the shot noise from noisy image by avoiding any harm to the image details. With this filtering technique, it is possible to preserve the sharp-edge and the details of the image without any damage during suppressing the noise from images. FWF-2D is one of the best techniques to suppress the corrupted quantum noises due to damaged X-ray tube. The fuzzy rules used in this filter are aimed to distinguish noise pixels from image ones, and the Wiener Filter is working to remove noise pixels distinguished by these fuzzy rules. It is then possible to obtain clean images from damaged X-ray tubes by using FWF-2D technique.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 50 条
  • [1] Quantum Noise Suppression in X-ray Images using Fuzzy 2-D Wiener Filter
    Abdullah Toprak
    Journal of Medical Systems, 2007, 31 : 351 - 355
  • [2] A novel method based on Wiener filter for denoising Poisson noise from medical X-Ray images
    Goreke, Volkan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [3] Fuzzy genetic-based noise removal filter for digital panoramic X-ray images
    Rafati, Mehravar
    Farnia, Fateme
    Taghvaei, Mahdi Erfanian
    Nickfarjam, Ali Mohammad
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2018, 38 (04) : 941 - 965
  • [4] Coronary Arteries Motion Modeling on 2-D X-ray Images
    Gao, Yang
    Sundar, Hari
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [5] Finding Magnetopause Standoff Distance Using a Soft X-ray Imager: 2. Methods to Analyze 2-D X-ray Images
    Samsonov, Andrey
    Sembay, Steven
    Read, Andrew
    Carter, Jennifer Alyson
    Branduardi-Raymont, Graziella
    Sibeck, David
    Escoubet, Philippe
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2022, 127 (12)
  • [6] 3-D/2-D registration of CT and MR to X-ray images
    Tomazevic, D
    Likar, B
    Slivnik, T
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1407 - 1416
  • [7] Quantizing calcification in the lumbar aorta on 2-D lateral X-ray images
    Conrad-Hansen, LA
    de Bruijne, M
    Lauze, F
    Tanko, LB
    Nielsen, M
    COMPUTER VISION FOR BIOMEDICAL IMAGE APPLICATIONS, PROCEEDINGS, 2005, 3765 : 409 - 418
  • [8] Quantizing calcification in the lumbar aorta on 2-D lateral X-ray images
    Conrad-Hansen, LA
    Lauze, F
    Tanko, LB
    Nielsen, M
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 1341 - 1347
  • [9] From stereoscopic X-ray images to 2 1/2-D volume visualisation
    Godber, SX
    Evans, JPO
    Robinson, M
    Murray, N
    Mason, P
    Lacey, D
    VISUAL DATA EXPLORATION AND ANALYSIS III, 1996, 2656 : 2 - 11
  • [10] 3D reconstruction of archaeological artefacts from 2-D X-ray images
    Angheluta, L. M.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2018, 12 (11-12): : 705 - 712