Electron-beam extraction system for the Frankfurt 14 GHz electron cyclotron resonance ion source

被引:4
|
作者
Runkel, S [1 ]
Hohn, O
Schmidt, L
Stiebing, KE
Schmidt-Bocking, H
Schempp, A
Becker, R
机构
[1] Univ Frankfurt, Inst Kernphys, D-60054 Frankfurt, Germany
[2] Univ Frankfurt, Inst Angew Phys, D-60054 Frankfurt, Germany
[3] Univ Frankfurt, Inst Kernphys, D-60486 Frankfurt, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1998年 / 69卷 / 02期
关键词
D O I
10.1063/1.1148561
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new concept to assist in the extraction of ion beams from an electron cyclotron resonance ion source (ECRIS) by the injection of an electron beam from the extraction side into the ion-source plasma is proposed. In this article, the construction of a test setup is described and first results of experiments with this setup at the 14 GHz ECRIS of the Frankfurt ECRIS-(ve)RFQ facility are reported. (C) 1998 American Institute of Physics.
引用
收藏
页码:721 / 723
页数:3
相关论文
共 50 条
  • [21] Experimental study of ion extraction from a 2.45 GHz electron cyclotron resonance multicharged ion source
    Kato, Y
    Sugiyama, S
    Ishii, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 601 - 603
  • [22] Upgrade of the extraction system of permanent magnet electron cyclotron resonance ion source
    Zhang, M.
    Peng, S. X.
    Ren, H. T.
    Song, Z. Z.
    Yuan, Z. X.
    Zhou, Q. F.
    Lu, P. N.
    Xu, R.
    Zhao, J.
    Yu, J. X.
    Chen, J. E.
    Guo, Z. Y.
    Lu, Y. R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [23] Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source
    Tarvainen, O.
    Kalvas, T.
    Koivisto, H.
    Komppula, J.
    Kronholm, R.
    Laulainen, J.
    Izotov, I.
    Mansfeld, D.
    Skalyga, V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [24] Production of U beam from RIKEN 18 GHz electron cyclotron resonance ion source
    Higurashi, Y.
    Nakagawa, T.
    Kidera, M.
    Haba, H.
    Aihara, T.
    Kase, M.
    Goto, A.
    Yano, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [25] 28 GHz 10 kW gyrotron system for electron cyclotron resonance ion source
    Bykov, Y
    Denisov, G
    Eremeev, A
    Gorbatushkov, V
    Kurkin, V
    Kalynova, G
    Kholoptsev, V
    Luchinin, A
    Plotnikov, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1437 - 1439
  • [26] Study of the Characteristics of a 2.45 GHz Electron Cyclotron Resonance Ion Source
    K. Berestov
    S. Bogomolov
    K. Kuzmenkov
    Physics of Particles and Nuclei Letters, 2023, 20 : 1246 - 1249
  • [27] SEISM: A 60 GHz cusp electron cyclotron resonance ion source
    Latrasse, L.
    Marie-Jeanne, M.
    Lamy, T.
    Thuillier, T.
    Giraud, J.
    Fourel, C.
    Trophime, C.
    Debray, F.
    Sala, P.
    Dumas, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [28] Development of a 14.5 GHz Electron Cyclotron Resonance Ion Source at KAERI
    Oh, Byung-Hoon
    In, Sang-Ryul
    Lee, Kwang-Won
    Seo, Chang Seog
    Jin, Jeong-Tae
    Chang, Dae-Sik
    Jeong, Seung-Ho
    Hwang, Churl-Kew
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (04) : 771 - 775
  • [29] Waveguide Development for a 2.46 GHz Electron Cyclotron Resonance Ion Source
    M. S. Dmitriev
    M. V. D’yakonov
    S. A. Tumanov
    Physics of Atomic Nuclei, 2022, 85 : 1899 - 1901
  • [30] Influence of the secondary electrons emitted by a cylindrical metal-dielectric structure on the Frankfurt 14 GHz electron cyclotron resonance ion source performances
    Schächter, L
    Stiebing, KE
    Dobrescu, S
    Badescu-Singureanu, AI
    Runkel, S
    Hohn, O
    Schmidt, L
    Schempp, A
    Schmidt-Böcking, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 918 - 920