Relationships between myocardial perfusion abnormalities and poststress left ventricular functional impairment on cadmium-zinc-telluride imaging

被引:17
|
作者
Gimelli, Alessia [1 ]
Liga, Riccardo [2 ]
Giorgetti, Assuero [1 ]
Kusch, Annette [1 ]
Pasanisi, Emilio Maria [1 ]
Marzullo, Paolo [1 ,3 ]
机构
[1] Fdn Toscana Gabriele Monasterio, I-56124 Pisa, Italy
[2] Univ Hosp Pisa, Cardio Thorac & Vasc Dept, Pisa, Italy
[3] CNR, Inst Clin Physiol, I-56100 Pisa, Italy
关键词
Myocardial perfusion imaging; Systolic dysfunction; Diastolic dysfunction; Ischaemic cascade; Cadmium-zinc-telluride; CORONARY-ARTERY-DISEASE; DIASTOLIC DYSFUNCTION; CONSCIOUS DOGS; ISCHEMIA; FLOW; ECHOCARDIOGRAPHY; ANGIOPLASTY; CAMERA; SPECT;
D O I
10.1007/s00259-015-3008-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the interplay between myocardial ischaemic burden and poststress left ventricular (LV) systolic and diastolic abnormalities in patients with suspected or known coronary artery disease (CAD). Methods A total of 471 patients underwent myocardial perfusion imaging by cadmium-zinc-telluride scintigraphy and coronary angiography. A fast imaging protocol was used with stress imaging performed 10 - 15 min after tracer injection. The summed difference score (SDS) and the percent stress-to-rest ratios for LV ejection fraction and peak filling rate (PFR), measures of stress-induced systolic and diastolic impairment, were computed from scintigraphic images. A SDS of > 3 was considered abnormal and > 7 a marker of moderate-to-severe ischaemia. Results Of the 471 patients, 321 (68 %) showed significant CAD in one (27 %), two (23 %) or three (18 %) vessels. The extent of CAD associated with gradual alterations in SDS (P < 0.001). Interestingly, while impairment in the percent stress-to-rest PFR ratio paralleled the increase in the extent of CAD (P < 0.001 for trend), the occurrence of significant stress-induced systolic dysfunction was limited to patients with multivessel disease (P < 0.001 vs. patients without CAD, and P = 0.002 vs. patients with single-vessel disease). Similarly, while a strict correlation between percent stress-to-rest PFR ratio and myocardial ischaemic burden was evident (P < 0.001), significant stress-induced LV systolic impairment was limited to patients with moderate-to-severe ischaemia (P < 0.001 vs. patients with no or mild ischaemia). Conclusion Stress-induced LV diastolic impairment is associated with a less extensive ischaemic burden and CAD extent than poststress systolic dysfunction, which is limited to patients with multivessel CAD.
引用
收藏
页码:994 / 1003
页数:10
相关论文
共 50 条
  • [41] Cadmium-Zinc-Telluride SPECT in Very Morbidly Obese Patients Routinely Provides High-Diagnostic-Quality Myocardial Perfusion Imaging REPLY
    Kaufmann, Philipp
    Gaemperli, Oliver
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (04) : 661 - 662
  • [42] Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography
    Michael Fiechter
    Jelena R. Ghadri
    Silke M. Kuest
    Aju P. Pazhenkottil
    Mathias Wolfrum
    Rene N. Nkoulou
    Robert Goetti
    Oliver Gaemperli
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 2025 - 2030
  • [43] REDUCING STUDY TIME FOR REST/STRESS 99MTC-TETROFOSMIN MYOCARDIAL PERFUSION IMAGING WITH MYOCARDIAL BLOOD FLOW MEASUREMENT USING CADMIUM-ZINC-TELLURIDE CAMERA IMAGING
    Kadoya, Yoshito
    Naji, Khalid
    Chow, Benjamin J. W.
    Small, Gary R.
    Wells, R. Glenn
    Ruddy, Terrence D.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 1448 - 1448
  • [44] Myocardial perfusion imaging with cadmium–zinc–telluride cameras: Harry Potter and the Radiation Hallows?
    Francesco Nudi
    Alessandro Nudi
    Giuseppe Biondi-Zoccai
    Orazio Schillaci
    Journal of Nuclear Cardiology, 2021, 28 : 1000 - 1004
  • [45] Myocardial Perfusion SPECT Imaging of Obese Patients on Cadmium Zinc Telluride (CZT) Camera
    Mallak, Nadine
    Menda, Yusuf
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [46] Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography
    Fiechter, Michael
    Ghadri, Jelena R.
    Kuest, Silke M.
    Pazhenkottil, Aju P.
    Wolfrum, Mathias
    Nkoulou, Rene N.
    Goetti, Robert
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (11) : 2025 - 2030
  • [47] Comparison of prone myocardial perfusion SPECT imaging for attenuation correction between cadmium-zinc-telluride and conventional Anger cameras utilizing a stress-only protocol.
    Panagiotou, Demetrios
    Kinkhabwala, Mona
    Weinberg, Richard
    Morgenstern, Rachelle
    Jin, Zhezhen
    DeLuca, Albert
    Bokhari, Sabahat
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [48] Changes in left ventricle myocardial volume during stress test using cadmium-zinc-telluride cardiac imaging: Implications in coronary artery disease
    Alessia Gimelli
    Nicola Riccardo Pugliese
    Ronny R. Buechel
    Michelangelo Bertasi
    Michele Coceani
    Paolo Marzullo
    Journal of Nuclear Cardiology, 2021, 28 : 1623 - 1633
  • [49] Changes in left ventricle myocardial volume during stress test using cadmium-zinc-telluride cardiac imaging: Implications in coronary artery disease
    Gimelli, Alessia
    Pugliese, Nicola Riccardo
    Buechel, Ronny R.
    Bertasi, Michelangelo
    Coceani, Michele
    Marzullo, Paolo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (04) : 1623 - 1633
  • [50] Influence of proton-pump inhibitors on stomach wall uptake of 99mTc-tetrofosmin in cadmium-zinc-telluride SPECT myocardial perfusion imaging
    Mouden, Mohamed
    Rijkee, Karlijn S.
    Schreuder, Nanno
    Timmer, Jorik R.
    Jager, Pieter L.
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (02) : 143 - 147