Study of the Rogowski coil response in a plasma focus device

被引:5
|
作者
Perusquia, S. [1 ]
Castillo, F. [2 ]
Reyes, P. G. [1 ]
Martinez, H. [2 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Ciencias, Lab Fis Avanzada, Toluca 50000, Estado De Mexic, Mexico
[2] Univ Nacl Autonoma Mexico, Inst Ciencias Fis, Lab Espect, Cuernavaca 62251, Morelos, Mexico
关键词
D O I
10.1088/1742-6596/591/1/012028
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In plasma physics is very important understand the behaviour and amplitude of high intensity currents. The high intensity current pulses are measured by resistive and inductive sensors. Coil configurations are employed in the same form as inductive sensors. Rogowski coil is a representative example; that coil consists of a toroidal-shaped winding. In this work we built a Rogowski coil. The coil operation was realized in a plasma focus device. The results show a good performance. We also used the coil to measure the current and voltage changes with respect to time, during the normal operation of the plasma focus device. The maximum value of the current (348kA) was obtained. As a complementary work, we analysed the results by changing the central electrode of the device (needle electrode, gap electrode and plane electrode). It founds that the pinch time is independent of the configuration of the central electrode.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A Calibrating Device for Rogowski Coil Development
    吕亮
    李军浩
    黄建军
    汲胜昌
    李彦明
    Plasma Science and Technology, 2007, (04) : 488 - 491
  • [2] A calibrating device for rogowski coil development
    Lv, Liang
    Li, Junhao
    Huang, Jianjun
    Ji, Shengchang
    Li, Yanming
    PLASMA SCIENCE & TECHNOLOGY, 2007, 9 (04) : 488 - 491
  • [3] A Calibrating Device for Rogowski Coil Development
    吕亮
    李军浩
    黄建军
    汲胜昌
    李彦明
    Plasma Science and Technology, 2007, 9 (04) : 488 - 491
  • [4] Fast response Rogowski coil with magnetic core
    Zhang Y.
    Liu J.
    Bai G.
    Liang B.
    Feng J.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (08): : 1954 - 1958
  • [5] Study on the reliability of PCB Rogowski coil
    College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    Gaoya Dianqi, 2006, 6 (421-423+427):
  • [6] Study of Measuring Error of Rogowski Coil
    Lu, S. M.
    Song, W. W.
    Huang, C.
    2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2019, : 1436 - 1442
  • [7] Ion beam measurement using Rogowski coils in a hundred of joules dense plasma focus device
    Jain, J.
    Moreno, J.
    Pavez, C.
    Bora, B.
    Inestrosa-Izurieta, M. J.
    Avaria, G.
    Soto, L.
    XIX CHILEAN PHYSICS SYMPOSIUM 2014, 2016, 720
  • [8] HIGH-FREQUENCY ROGOWSKI COIL RESPONSE CHARACTERISTICS
    STYGAR, W
    GERDIN, G
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1982, 10 (01) : 40 - 44
  • [9] Method for calibrating a Rogowski coil of fast time response
    Liu, Rui
    Wang, Xinxin
    Zou, Xiaobing
    Yuan, Jianqiang
    Zou, Naigong
    He, Luya
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (08):
  • [10] PHOTOGRAPHIC STUDY OF A PLASMA FOCUS DEVICE
    PATTERSO.EL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (11): : 1463 - &