Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiography

被引:63
|
作者
Oelerich, M [1 ]
Lentschig, MG [1 ]
Zunker, P [1 ]
Reimer, P [1 ]
Rummeny, EJ [1 ]
Schuierer, G [1 ]
机构
[1] Univ Munster, Inst Clin Radiol, D-48129 Munster, Germany
关键词
intracranial blood vessels; stenosis and occlusion; magnetic resonance angiography;
D O I
10.1007/s002340050645
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We compared the value of 3D time-of-flight (TOF) and phase-contrast (PC) MR angiography (MRA) for detection and grading of intracranial vascular steno-occlusive disease, Unenhanced 3D-TOF MRA and 3D-PC MRA (30-60 cm/s velocity encoding) were performed at the level of the circle of Willis in 18 patients, mean age 56 +/- 10 years. Postprocessed images using a maximum-intensity projection reconstruction with multiple targetted projections were analysed. A total of 126 vessels was assessed by PC MRA and 143 by TOF MRA, with digital subtraction angiography (DSA) in 15 patients and/or transcranial Doppler sonography (TCD) in 18 as a standard. Two blinded readers reviewed the MRA, DSA and TCD examinations retrospectively. On DSA and/or TCD the two observers found 32 and 28 steno-occlusive lesions. 3D-TOF MRA was more sensitive than 3D-PC MRA (87% and 86% vs. 65% and 60%) and had a higher negative predictive value (96% vs. 89%). Correct grading of stenoses was achieved in 78% by 3D-TOF and 65% by 3D-PC MRA.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [41] 3D phase contrast EPI MR angiography of the carotid arteries
    Debatin, J.F., 1600, Lippincott Williams and Wilkins (19):
  • [42] Prospective optical motion correction for 3D time-of-flight angiography
    Kopeinigg, Daniel
    Aksoy, Murat
    Forman, Christoph
    Straka, Matus
    Seaman, Danielle
    Rosenberg, Jarrett
    Fleischmann, Dominik
    Hornegger, Joachim
    Bammer, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (06) : 1623 - 1633
  • [43] COMPARISON OF TIME-OF-FLIGHT AND PHASE-CONTRAST MR NEUROANGIOGRAPHIC TECHNIQUES
    HUSTON, J
    EHMAN, RL
    RADIOGRAPHICS, 1993, 13 (01) : 5 - 19
  • [44] ACUTE SUBARACHNOID HEMORRHAGE - 3D TIME-OF-FLIGHT MR-ANGIOGRAPHY VERSUS INTRAARTERIAL DIGITAL ANGIOGRAPHY
    ANZALONE, N
    TRIULZI, F
    SCOTTI, G
    NEURORADIOLOGY, 1995, 37 (04) : 257 - 261
  • [45] Application of superparamagnetic iron oxide (AMI-227) for 3D phase-contrast MR angiography
    Tanimoto, A
    Yuasa, Y
    Hiramatsu, K
    ACADEMIC RADIOLOGY, 1998, 5 : S113 - S115
  • [46] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [47] Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: A comparison with time-of-flight MR angiography
    Nael, K.
    Villablanca, J. P.
    Saleh, R.
    Pope, W.
    Nael, A.
    Laub, G.
    Finn, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (10) : 2118 - 2121
  • [48] RENAL-ARTERIES - EVALUATION WITH OPTIMIZED 2D AND 3D TIME-OF-FLIGHT MR-ANGIOGRAPHY
    FELLNER, C
    STROTZER, M
    GEISSLER, A
    KOHLER, SM
    KRAMER, BK
    SPIES, V
    HELD, P
    GMEINWIESER, J
    RADIOLOGY, 1995, 196 (03) : 681 - 687
  • [49] Ultrafast time-of-flight 3D LiDAR
    Lum, Daniel J.
    NATURE PHOTONICS, 2020, 14 (01) : 2 - 4
  • [50] Ultrafast time-of-flight 3D LiDAR
    Daniel J. Lum
    Nature Photonics, 2020, 14 : 2 - 4