Echocardiographic and angiographic assessment of paravalvular regurgitation after TAVI: optimizing inter-technique reproducibility

被引:21
|
作者
Abdelghani, Mohammad [1 ]
Tateishi, Hiroki [2 ]
Spitzer, Ernest [3 ]
Tijssen, Jan G. [1 ]
de Winter, Robbert J. [1 ]
Soliman, Osama I. I. [2 ,3 ]
Hahn, Rebecca T. [4 ]
Serruys, Patrick W. [5 ]
机构
[1] Acad Med Ctr, Amsterdam, Netherlands
[2] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[3] Cardialysis Core Labs & Clin Trial Management, Rotterdam, Netherlands
[4] Columbia Univ, Med Ctr, New York Presbyterian Hosp, New York, NY USA
[5] Imperial Coll London, NHLI, Int Ctr Circulatory Hlth, London, England
关键词
Aortic regurgitation; Angiography; Doppler echocardiography; Transcatheter aortic valve implantation; TRANSCATHETER AORTIC-VALVE; NATIVE VALVULAR REGURGITATION; EDWARDS SAPIEN-XT; TRANSTHORACIC ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; MEDTRONIC COREVALVE; MAGNETIC-RESONANCE; IMPLANTATION; REPLACEMENT; SEVERITY;
D O I
10.1093/ehjci/jew083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) is often first diagnosed by angiography and then confirmed and followed-up by transthoracic echocardiography (TTE). Consistency between bothmethods is important for follow-up. We sought to determine inter-technique reproducibility of the assessment of paravalvular AR after TAVI. Methods and results The study included 165 patients treated with a self-expanding bioprosthesis and had angiography and TTE performed at a median interval of 4 days. TTE parameters of AR severity included VARC score (the average AR grade determined by the echocardiographic VARC-II criteria), pressure half time (PHT), regurgitation jet features in long-axis views (LAX score) and colour Doppler (CD) score (= paravalvular AR jet circumferential extent (%) + LAX score). Using receiver-operating characteristics curves, the cut-points that best defined an angiographic. mild AR were identified. On TTE, AR was paravalvular in all cases, multi-jet in 28%, and predominantly (64%) detected in the commissural region between the right and left coronary sinuses. Using VARC-II criteria (combining at least two), TTE agreed with angiographic classification in 53% of cases (k = 0.14). Greater than mild AR could better be defined by one of the following combinations of criteria: (i) LAX score >4.25 and VARC-II score >1.33; (ii) CD score >11.5 and PHT < 400 ms. The combination of the CD score with PHT gave the best sum of sensitivity, specificity, positive, and negative predictive values. Conclusions Agreement between angiography and TTE (using the VARC-II criteria) in the grading of post-TAVI AR is modest, and this might have contributed to the inconsistency of data on the rate and fate of paravalvular AR. Inter-technique reproducibility can be improved using a combination of CD and hemodynamic parameters.
引用
收藏
页码:852 / 860
页数:9
相关论文
共 50 条
  • [31] CARDIAC MRI IN ASSESSMENT OF PARAVALVULAR AORTIC REGURGITATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Aman, Wahaj
    Zhan, Yang
    Shah, Dipan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2996 - 2996
  • [32] The Aortic Valve Calcium Nodule Score (AVCNS) independently predicts paravalvular regurgitation after Transcatheter Aortic Valve Implantation (TAVI)
    Azzalini, L.
    Ghoshhajra, B.
    Elmariah, S.
    Passeri, J. J.
    Inglessis, I.
    Palacios, I.
    Abbara, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 840 - 840
  • [33] Does pre-existing aortic regurgitation protect from death in patients who develop paravalvular leak after TAVI?
    Colli, Andrea
    Besola, Laura
    Salizzoni, Stefano
    Gregori, Dario
    Tarantini, Giuseppe
    Agrifoglio, Marco
    Chieffo, Alaide
    Regesta, Tommaso
    Gabbieri, Davide
    Saia, Francesco
    Tamburino, Corrado
    Ribichini, Flavio
    Valsecchi, Orazio
    Loi, Bruno
    Iadanza, Alessandro
    Stolcova, Miroslava
    Minati, Alessandro
    Martinelli, Gianluca
    Bedogni, Francesco
    Petronio, Anna
    Dallago, Michele
    Cappai, Antioco
    D'Onofrio, Augusto
    Gerosa, Gino
    Rinaldi, Mauro
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 233 : 52 - 60
  • [34] Echocardiographic Evaluation of Paravalvular Regurgitation After Transarterial Valve Implantation Based on the Academic Valve Research Consortium 2 Recommendations
    Alexandru, Dragos
    Pollack, Simcha
    Petillo, Florentina
    Mihalatos, Dennis
    Barasch, Eddy
    CIRCULATION, 2016, 134
  • [35] Anatomical predictors of paravalvular aortic regurgitation (AoI) after transcatheter aortic valve implantation (TAVI) detected by multidetetctor computed tomography (MDCT)
    Pontone, G.
    Andreini, D.
    Bartorelli, A. L.
    Annoni, A.
    Mushtaq, S.
    Bertella, E.
    Fusari, M.
    Ballerini, G.
    Fiorentini, C.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1010 - 1010
  • [36] Hemodynamic assessment of residual paravalvular aortic regurgitation after TAVI: impact of pressure difference (Diastolic Aortic Pressure-LVEDP) and myocardial supply-demand ratio on survival
    Patsalis, P. C.
    Konorza, T. F. M.
    Al-Rashid, F.
    Plicht, B.
    Wendt, D.
    Thielmann, M.
    Jakob, H.
    Heusch, G.
    Erbel, R.
    Kahlert, P. H.
    EUROPEAN HEART JOURNAL, 2012, 33 : 194 - 194
  • [37] Assessment of the Severity of Paravalvular Regurgitation and its Role on Survival After Transcatheter Aortic Valve Replacement
    Sannino, Anna
    Stoler, Robert C.
    Vallabhan, Ravi
    Potluri, Srinivasa
    Pollock, Benjamin
    Filardo, Giovanni
    Mack, Michael J.
    Grayburn, Paul A.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (01): : 24 - 30
  • [38] INVASIVE AND NON-INVASIVE ASSESSMENT OF PULMONIC REGURGITATION - CLINICAL, ANGIOGRAPHIC, PHONOCARDIOGRAPHIC, ECHOCARDIOGRAPHIC, AND DOPPLER ULTRASOUND CORRELATIONS
    CHANDRARATNA, PAN
    WILSON, D
    IMAIZUMI, T
    RITTER, WS
    ARONOW, WS
    CLINICAL CARDIOLOGY, 1982, 5 (06) : 360 - 365
  • [39] Quantitative angiographic assessment of aortic regurgitation post 11 different types of TAVI devices a multicentre pooled analysis of 2665 valves
    Abdelshafy, M.
    Soliman, O.
    Kim, W.
    Ruck, A.
    Elkoumy, A.
    Elzomor, H.
    Wang, R.
    Tao, L.
    Garg, S.
    Mylotte, D.
    Onuma, Y.
    Serruys, P.
    EUROPEAN HEART JOURNAL, 2022, 43 : 2078 - 2078
  • [40] Echocardiographic assessment of tricuspid regurgitation and pericardial effusion after cardiac device implantation
    Wiechecka, Katarzyna
    Wiechecki, Bartosz
    Kaplon-Cieslicka, Agnieszka
    Tyminska, Agata
    Budnik, Monika
    Holowaty, Dominika
    Jakubowski, Krzysztof
    Michalak, Marcin
    Swieton, Elzbieta
    Stolarz, Przemyslaw
    Steckiewicz, Roman
    Grabowski, Marcin
    Scislo, Piotr
    Kochanowski, Janusz
    Filipiak, Krzysztof J.
    Opolski, Grzegorz
    CARDIOLOGY JOURNAL, 2020, 27 (06) : 797 - 806