The operating line for activated sludge

被引:2
|
作者
Brown, DE [1 ]
机构
[1] Cranfield Univ, Cranfield Biotechnol Ctr, Cranfield MK43 0AL, Beds, England
关键词
activated sludge; chemical oxygen demand; mass balance; oxygen;
D O I
10.1023/A:1008917320704
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The mass balance for O-2 on an activated sludge process has been re-arranged to identify the O-2 limited boundary for any given treatment installation and for any combination of feed flow rate and input bCOD. The boundary is described graphically as the operating line.
引用
收藏
页码:185 / 186
页数:2
相关论文
共 50 条
  • [21] On-line optical monitoring of activated sludge floc morphology
    Koivuranta, E.
    Stoor, T.
    Hattuniemi, J.
    Niinimaki, J.
    JOURNAL OF WATER PROCESS ENGINEERING, 2015, 5 : 28 - 34
  • [22] PHENOLIC WASTES TREATMENT BY ACTIVATED SLUDGE PROCESS - OPERATING CONDITION AND ACTUAL OPERATION
    NAKASHIO, M
    JOURNAL OF FERMENTATION TECHNOLOGY, 1969, 47 (06): : 389 - &
  • [23] Dynamical modelling of an activated sludge system of a petrochemical plant operating at high temperatures
    Maqueda, M. A. M.
    Martinez D, Sergio A.
    Narvaez, D.
    Rodriguez R, Miriam G.
    Aguilar L, Ricardo
    Herrero V, Victor M.
    WATER SCIENCE AND TECHNOLOGY, 2006, 53 (11) : 135 - 142
  • [24] Effect of operating conditions on the behavior of activated sludge in phenolic waste water treatment
    Hirata, Akira
    Kiuchi, Kazutoshi
    Chatani, Masaaki
    Suda, Hideki
    1600, Society of Chemical Engineers, Japan (05):
  • [25] Optimization of operating conditions in the biological enzymes for efficient waste activated sludge dewatering
    Kang, Xu
    Li, Chaolin
    Ding, Wanqing
    Ma, Yuhao
    Gao, Shuhong
    Zhou, Xu
    Chen, Yidi
    Liu, Wenzong
    Jiang, Guangming
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 170 : 545 - 552
  • [27] Operating costs related to instability in a pulp and paper activated sludge treatment system
    Brault, Jean-Martin
    Leroux, Roger
    Stuart, Paul
    TAPPI JOURNAL, 2009, 8 (10): : 27 - 32
  • [28] Operating and maintenance costs of wastewater treatment plant by anaerobic reactor and activated sludge
    Souza, Bruno de Medeiros
    Calazans Duarte, Marco Antonio
    Tinoco, Juliana Delgado
    ENGENHARIA SANITARIA E AMBIENTAL, 2021, 26 (03) : 505 - 515
  • [29] STUDY ON EXPERIMENTAL ACTIVATED-SLUDGE SYSTEM OPERATING UNDER TROPICAL CONDITIONS
    HERMOSO, M
    HERRERA, J
    LOPEZ, E
    RODRIGUEZ, F
    TUGUES, L
    ACTA CIENTIFICA VENEZOLANA, 1977, 28 : 111 - 111
  • [30] Copper(II) ion toxicity in activated sludge processes as function of operating parameters
    Pamukoglu, M. Yunus
    Kargi, Fikret
    ENZYME AND MICROBIAL TECHNOLOGY, 2007, 40 (05) : 1228 - 1233