Non-Invasive Estimation of Intracranial Pressure by Diffuse Optics: A Proof-of-Concept Study

被引:25
|
作者
Fischer, Jonas B. [1 ,2 ]
Ghouse, Ameer [1 ]
Tagliabue, Susanna [1 ]
Maruccia, Federica [1 ,3 ]
Rey-Perez, Anna [4 ]
Baguena, Marcelino [4 ]
Cano, Paola [5 ]
Zucca, Riccardo [6 ]
Weigel, Udo M. [2 ]
Sahuquillo, Juan [3 ,5 ]
Poca, Maria A. [3 ,5 ]
Durduran, Turgut [1 ,7 ]
机构
[1] Barcelona Inst Sci & Technol, ICFO Inst Ciencies Foton, Barcelona, Spain
[2] HemoPhoton SL, Barcelona, Spain
[3] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, Neurotraumatol & Neurosurg Res Unit UNINN, Barcelona, Spain
[4] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, Neurotrauma Intens Care Unit, Barcelona, Spain
[5] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, Dept Neurosurg, Barcelona, Spain
[6] Barcelona Inst Sci & Technol, Inst Bioengn Catalonia IBEC, Synthet Percept Emot & Cognit Syst SPECS, Barcelona, Spain
[7] Inst Catalana Recerca & Estudis Avancats ICREA, Barcelona, Spain
基金
欧盟地平线“2020”;
关键词
diffuse optics; intracranial pressure; near-infrared spectroscopy; neural networks; non-invasive; BLOOD-FLOW; TRANSCRANIAL DOPPLER; CORRELATION SPECTROSCOPY; EPIDURAL SPACE; BRAIN;
D O I
10.1089/neu.2019.6965
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Intracranial pressure (ICP) is an important parameter to monitor in several neuropathologies. However, because current clinically accepted methods are invasive, its monitoring is limited to patients in critical conditions. On the other hand, there are other less critical conditions for which ICP monitoring could still be useful; therefore, there is a need to develop non-invasive methods. We propose a new method to estimate ICP based on the analysis of the non-invasive measurement of pulsatile, microvascular cerebral blood flow with diffuse correlation spectroscopy. This is achieved by training a recurrent neural network using only the cerebral blood flow as the input. The method is validated using a 50% split sample method using the data from a proof-of-concept study. The study involved a population of infants (n = 6) with external hydrocephalus (initially diagnosed as benign enlargement of subarachnoid spaces) as well as a population of adults (n = 6) with traumatic brain injury. The algorithm was applied to each cohort individually to obtain a model and an ICP estimate. In both diverse cohorts, the non-invasive estimation of ICP was achieved with an accuracy of <4 mm Hg and a negligible small bias. Further, we have achieved a good correlation (Pearson's correlation coefficient >0.9) and good concordance (Lin's concordance correlation coefficient >0.9) in comparison with standard clinical, invasive ICP monitoring. This preliminary work paves the way for further investigations of this tool for the non-invasive, bedside assessment of ICP.
引用
收藏
页码:2569 / 2579
页数:11
相关论文
共 50 条
  • [41] Non-invasive indirect monitoring of intra-abdominal pressure using microwave reflectometry: system design and proof-of-concept clinical trial
    Marcelo David
    Aviad Raviv
    Ariel Guttel
    Valentina García Reyes
    Franco Simini
    Francisco Pracca
    Journal of Clinical Monitoring and Computing, 2021, 35 : 1437 - 1443
  • [42] Non-invasive indirect monitoring of intra-abdominal pressure using microwave reflectometry: system design and proof-of-concept clinical trial
    David, Marcelo
    Raviv, Aviad
    Guttel, Ariel
    Garcia Reyes, Valentina
    Simini, Franco
    Pracca, Francisco
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (06) : 1437 - 1443
  • [43] Urinary Polyomavirus-Haufen Shedding in Mouse and Man: A Proof-of-Concept Study for a Non-Invasive Urine Biomarker for Polyomavirus Nephropathy
    Nickeleit, V.
    Brylawski, B.
    Singh, H.
    Rivier, L.
    LABORATORY INVESTIGATION, 2013, 93 : 390A - 391A
  • [44] Non-invasive real-time assessment of hepatic macrovesicular steatosis in liver donors: Hypothesis, design and proof-of-concept study
    Rajamani, Allwyn S.
    Rammohan, Ashwin
    Sai, Vv Raghavendra
    Rela, Mohamed
    WORLD JOURNAL OF HEPATOLOGY, 2021, 13 (10) : 1208 - 1214
  • [45] Quantitative liver MRI including extracellular volume fraction for non-invasive quantification of liver fibrosis: a prospective proof-of-concept study
    Luetkens, Julian A.
    Klein, Sabine
    Traeber, Frank
    Schmeel, Frederic C.
    Sprinkart, Alois M.
    Kuetting, Daniel L. R.
    Block, Wolfgang
    Hittatiya, Kanishka
    Uschner, Frank E.
    Schierwagen, Robert
    Gieseke, Juergen
    Schild, Hans H.
    Trebicka, Jonel
    Kukuk, Guido M.
    GUT, 2018, 67 (03) : 592 - +
  • [46] Urinary Polyomavirus-Haufen Shedding in Mouse and Man: A Proof-of-Concept Study for a Non-Invasive Urine Biomarker for Polyomavirus Nephropathy
    Nickeleit, V.
    Brylawski, B.
    Singh, H.
    Rivier, L.
    MODERN PATHOLOGY, 2013, 26 : 390A - 391A
  • [47] A non-invasive capacitive sensor to investigate the Leidenfrost phenomenon: a proof of concept study
    Purandare, Abhishek S.
    Rijs, Jelle
    Sagar, Pankaj
    Vanapalli, Srinivas
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [48] Non-invasive real-time assessment of hepatic macrovesicular steatosis in liver donors:Hypothesis,design and proof-of-concept study
    Allwyn S Rajamani
    Ashwin Rammohan
    VV Raghavendra Sai
    Mohamed Rela
    World Journal of Hepatology, 2021, 13 (10) : 1208 - 1214
  • [49] Non-invasive monitoring of intracranial pressure changes: healthy volunteers study
    Roldan, Maria
    Bradley, George R. E.
    Mejia-Mejia, Elisa
    Abay, Tomas Y.
    Kyriacou, Panayiotis A.
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [50] Detecting aortic valve stenosis based on the non-invasive blood pressure waveform-a proof of concept study
    Kho, Eline
    Schenk, Jimmy
    Vlaar, Alexander P. J.
    Vis, Marije M.
    Wijnberge, Marije
    Stam, Lotte B.
    van Mourik, Martijn
    Jorstad, Harald T.
    Hermanns, Henning
    Westerhof, Berend E.
    Veelo, Denise P.
    van der Ster, Bjorn J. P.
    GEROSCIENCE, 2024, 46 (06) : 5955 - 5965