Non-Invasive Estimation of Intracranial Pressure by Diffuse Optics: A Proof-of-Concept Study

被引:25
|
作者
Fischer, Jonas B. [1 ,2 ]
Ghouse, Ameer [1 ]
Tagliabue, Susanna [1 ]
Maruccia, Federica [1 ,3 ]
Rey-Perez, Anna [4 ]
Baguena, Marcelino [4 ]
Cano, Paola [5 ]
Zucca, Riccardo [6 ]
Weigel, Udo M. [2 ]
Sahuquillo, Juan [3 ,5 ]
Poca, Maria A. [3 ,5 ]
Durduran, Turgut [1 ,7 ]
机构
[1] Barcelona Inst Sci & Technol, ICFO Inst Ciencies Foton, Barcelona, Spain
[2] HemoPhoton SL, Barcelona, Spain
[3] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, Neurotraumatol & Neurosurg Res Unit UNINN, Barcelona, Spain
[4] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, Neurotrauma Intens Care Unit, Barcelona, Spain
[5] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, Dept Neurosurg, Barcelona, Spain
[6] Barcelona Inst Sci & Technol, Inst Bioengn Catalonia IBEC, Synthet Percept Emot & Cognit Syst SPECS, Barcelona, Spain
[7] Inst Catalana Recerca & Estudis Avancats ICREA, Barcelona, Spain
基金
欧盟地平线“2020”;
关键词
diffuse optics; intracranial pressure; near-infrared spectroscopy; neural networks; non-invasive; BLOOD-FLOW; TRANSCRANIAL DOPPLER; CORRELATION SPECTROSCOPY; EPIDURAL SPACE; BRAIN;
D O I
10.1089/neu.2019.6965
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Intracranial pressure (ICP) is an important parameter to monitor in several neuropathologies. However, because current clinically accepted methods are invasive, its monitoring is limited to patients in critical conditions. On the other hand, there are other less critical conditions for which ICP monitoring could still be useful; therefore, there is a need to develop non-invasive methods. We propose a new method to estimate ICP based on the analysis of the non-invasive measurement of pulsatile, microvascular cerebral blood flow with diffuse correlation spectroscopy. This is achieved by training a recurrent neural network using only the cerebral blood flow as the input. The method is validated using a 50% split sample method using the data from a proof-of-concept study. The study involved a population of infants (n = 6) with external hydrocephalus (initially diagnosed as benign enlargement of subarachnoid spaces) as well as a population of adults (n = 6) with traumatic brain injury. The algorithm was applied to each cohort individually to obtain a model and an ICP estimate. In both diverse cohorts, the non-invasive estimation of ICP was achieved with an accuracy of <4 mm Hg and a negligible small bias. Further, we have achieved a good correlation (Pearson's correlation coefficient >0.9) and good concordance (Lin's concordance correlation coefficient >0.9) in comparison with standard clinical, invasive ICP monitoring. This preliminary work paves the way for further investigations of this tool for the non-invasive, bedside assessment of ICP.
引用
收藏
页码:2569 / 2579
页数:11
相关论文
共 50 条
  • [1] A PROOF-OF-CONCEPT STUDY OF A NOVEL NON-INVASIVE GLUCOSE MONITOR
    Devries, H.
    Qureshi, M. Rafaqat Ali
    Zijlstra, E.
    Plum-Moerschel, L.
    Handy, C. M.
    Love, B.
    Chaudhry, S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A62 - A63
  • [2] Non-Invasive Assessment of Coronary Stenoses and Comparison to Invasive Techniques: a proof-of-concept study
    Tsompou, Panagiota I.
    Siogkas, Panagiotis K.
    Sakellarios, Antonis I.
    Fotiadis, Dimitrios I.
    Lemos, Pedro A.
    Michaelideion, Lampros K. Michalis
    2017 IEEE 30TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2017, : 328 - 331
  • [3] Non-invasive vagus nerve stimulation for rheumatoid arthritis: a proof-of-concept study
    Marsal, Sara
    Corominas, Hector
    Jose de Agustin, Juan
    Perez-Garcia, Carolina
    Lopez-Lasanta, Maria
    Borrell, Helena
    Reina, Delia
    Sanmarti, Raimon
    Narvaez, Javier
    Franco-Jarava, Clara
    Peterfy, Charles
    Antonio Narvaez, Jose
    Sharma, Vivek
    Alataris, Konstantinos
    Genovese, Mark C.
    Baker, Matthew C.
    LANCET RHEUMATOLOGY, 2021, 3 (04): : E262 - E269
  • [4] Non-invasive brain stimulation in information systems research: A proof-of-concept study
    Dumont, Laurence
    Larochelle-Brunet, Felix
    Theoret, Hugo
    Riedl, Rene
    Senecal, Sylvain
    Leger, Pierre-Majorique
    PLOS ONE, 2018, 13 (07):
  • [5] A novel non-invasive electromagnetic extendable intercalary endoprosthesis: a proof-of-concept study
    Huang, Siyi
    Yang, Jiake
    Li, Xinyu
    Tang, Xiaodong
    Ji, Tao
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [6] TRANSPLANTATION AND NON-INVASIVE LONGITUDINAL IN VIVO IMAGING OF PARATHYROID CELLS - A PROOF-OF-CONCEPT STUDY
    Branstrom, R.
    Van Krieken, P.
    Frobom, R.
    Shabo, I
    Aspinwall, C. A.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [7] Parameters recorded by software of non-invasive ventilators predict COPD exacerbation: a proof-of-concept study
    Borel, Jean-Christian
    Pelletier, Julie
    Taleux, Nellie
    Briault, Amandine
    Arnol, Nathalie
    Pison, Christophe
    Tamisier, Renaud
    Timsit, Jean-Francois
    Pepin, Jean-Louis
    THORAX, 2015, 70 (03) : 284 - 285
  • [8] PROOF-OF-CONCEPT STUDY USING NON-INVASIVE ELECTRICAL MUSCLE STIMULATION FOR ENGAGEMENT OF RESPIRATORY MUSCLES
    Sheth, M.
    Malik, M.
    THORAX, 2022, 77 : A179 - A179
  • [9] Proof of concept non-invasive estimation of peripheral venous oxygen saturation
    Musabbir Khan
    Chris G. Pretty
    Alexander C. Amies
    Joel Balmer
    Houda E. Banna
    Geoffrey M. Shaw
    J. Geoffrey Chase
    BioMedical Engineering OnLine, 16
  • [10] Proof of concept non-invasive estimation of peripheral venous oxygen saturation
    Khan, Musabbir
    Pretty, Chris G.
    Amies, Alexander C.
    Balmer, Joel
    Banna, Houda E.
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16