Full range 1-μm spectral domain optical coherence tomography by using electro-optical phase modulator

被引:1
|
作者
Fabritius, Tapio [1 ,2 ]
Makita, Shuichi [1 ]
Yamanari, Masahiro [1 ]
Myllylae, Risto [2 ]
Yatagai, Toyohiko [3 ]
Yasuno, Yoshiaki [1 ]
机构
[1] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki, Japan
[2] Univ Oulu, Optoelect & Measuremen Tech Lab, Oulu, Finland
[3] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki, Japan
关键词
opthalmology; biomedical imaging; signal processing;
D O I
10.1117/12.765403
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-mu m band light source is demonstrated. The phase of reference arm is modulated simultaneously as the probing beam laterally scans the sample (B-scan). The obtained two dimensional spectral interferogram. is processed by Fourier transform method to obtain complex spectrum which leads to full-range OCT image. The measurement speed of this system was 7.96 kHz, the measured axial resolution was 9.6 mu m in air and the sensitivity was 99.4 dB. To demonstrate the effect of mirror image elimination, in vivo human eye pathology was measured.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm
    Li, Peng
    Johnstone, Murray
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (04)
  • [42] High-speed full-range spectral-domain correlation mapping optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2013, 8580
  • [43] Single-camera full-range high-resolution spectral domain optical coherence tomography
    Bo, En
    Chen, Si
    Cui, Dongyao
    Chen, Shi
    Yu, Xiaojun
    Luo, Yuemei
    Liu, Linbo
    APPLIED OPTICS, 2017, 56 (03) : 470 - 475
  • [44] Full-Range, Complex-Conjugate-Free, Endoscopic Spectral-Domain Optical Coherence Tomography
    Zhang, Kang
    Huang, Yong
    Kang, Jin U.
    2011 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2011,
  • [45] Five-Frame Variable Phase-Shifting Method for Full-Range Spectral-Domain Optical Coherence Tomography
    Lin, Jiewen
    Zhong, Shuncong
    Zhang, Qiukun
    Chen, Weiqiang
    APPLIED SCIENCES-BASEL, 2018, 8 (09):
  • [46] Ultralong-range phase imaging with orthogonal dispersive spectral-domain optical coherence tomography
    Wang, Chuan
    Ding, Zhihua
    Mei, Shengtao
    Yu, Hang
    Hong, Wei
    Yan, Yangzhi
    Shen, Weidong
    OPTICS LETTERS, 2012, 37 (21) : 4555 - 4557
  • [47] 1 GHz electro-optical silicon-germanium modulator in the 5-9 μm wavelength range
    Nguyen, Thi Hao Nhi
    Koompai, Natnicha
    Turpaud, Victor
    Montesinos-Ballester, Miguel
    Peltier, Jonathan
    Frigerio, Jacopo
    Ballabio, Andrea
    Giani, Raffaele
    Coudevylle, Jean-Rene
    Villebasse, Cedric
    Bouville, David
    Alonso-ramos, Carlos
    Vivien, Laurent
    Isella, Giovanni
    Marris-Morini, Delphine
    OPTICS EXPRESS, 2022, 30 (26) : 47093 - 47102
  • [48] Measurement of the modulation index of a M-Z electro-optical modulator using an optical spectrum analyzer
    Yi, Hong
    Wu, Boyu
    Zhou, Weiqin
    Li, Yanfei
    Yang, Hui
    Zhang, Bing
    Peng, Jihu
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2002, 42 (01): : 4 - 6
  • [49] Spectral-domain optical coherence tomography: Removal of autocorrelation using an optical switch
    Ai, J
    Wang, LHV
    APPLIED PHYSICS LETTERS, 2006, 88 (11)
  • [50] Structural and optical characterization of banknotes using spectral-domain optical coherence tomography
    Wang, Lei
    Wu, Di
    Yv, Siyi
    Wang, Chengming
    Guang, Xiaoli
    Shi, Gaojun
    Yan, Yuwen
    Xie, Lanchi
    Huang, Wei
    Li, Zhigang
    Gao, Shuhui
    Zhang, Ning
    JOURNAL OF FORENSIC SCIENCES, 2022, 67 (05) : 2073 - 2081